A magnetic resonance (MR) microscopy system using a microfluidically cryo-cooled planar coil

被引:10
|
作者
Koo, Chiwan [1 ]
Godley, Richard F. [2 ]
Park, Jaewon [2 ]
McDougall, Mary P. [1 ,2 ]
Wright, Steven M. [1 ,2 ]
Han, Arum [1 ,2 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX 77843 USA
基金
美国国家卫生研究院;
关键词
MICROPUMP; PERFORMANCE; VLSI;
D O I
10.1039/c1lc20056a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present the development of a microfluidically cryo-cooled planar coil for magnetic resonance (MR) microscopy. Cryogenically cooling radiofrequency (RF) coils for magnetic resonance imaging (MRI) can improve the signal to noise ratio (SNR) of the experiment. Conventional cryostats typically use a vacuum gap to keep samples to be imaged, especially biological samples, at or near room temperature during cryo-cooling. This limits how close a cryo-cooled coil can be placed to the sample. At the same time, a small coil-to-sample distance significantly improves the MR imaging capability due to the limited imaging depth of planar MR microcoils. These two conflicting requirements pose challenges to the use of cryo-cooling in MR microcoils. The use of a microfluidic based cryostat for localized cryo-cooling of MR microcoils is a step towards eliminating these constraints. The system presented here consists of planar receive-only coils with integrated cryo-cooling microfluidic channels underneath, and an imaging surface on top of the planar coils separated by a thin nitrogen gas gap. Polymer microfluidic channel structures fabricated through soft lithography processes were used to flow liquid nitrogen under the coils in order to cryo-cool the planar coils to liquid nitrogen temperature (-196 degrees C). Two unique features of the cryo-cooling system minimize the distance between the coil and the sample: (1) the small dimension of the polymer microfluidic channel enables localized cooling of the planar coils, while minimizing thermal effects on the nearby imaging surface. (2) The imaging surface is separated from the cryo-cooled planar coil by a thin gap through which nitrogen gas flows to thermally insulate the imaging surface, keeping it above 0 degrees C and preventing potential damage to biological samples. The localized cooling effect was validated by simulations, bench testing, and MR imaging experiments. Using this cryo-cooled planar coil system inside a 4.7 Tesla MR system resulted in an average image SNR enhancement of 1.47 +/- 0.11 times relative to similar room-temperature coils.
引用
收藏
页码:2197 / 2203
页数:7
相关论文
共 50 条
  • [41] A novel radio frequency coil for veterinary magnetic resonance imaging system
    Meng Bin
    Huang Kai-Wen
    Wang Wei-Min
    CHINESE PHYSICS B, 2010, 19 (07)
  • [42] A novel radio frequency coil for veterinary magnetic resonance imaging system
    孟斌
    黄开文
    王为民
    Chinese Physics B, 2010, 19 (07) : 412 - 417
  • [43] Magnetic exchange force microscopy using ferromagnetic resonance
    Xue Hui
    Ma Zong-Min
    Shi Yun-Bo
    Tang Jun
    Xue Chen-Yang
    Liu Jun
    Li Yan-Jun
    ACTA PHYSICA SINICA, 2013, 62 (18)
  • [44] Small animal neuroimaging using magnetic resonance microscopy
    Ahrens, ET
    Narasimhan, PT
    Nakada, T
    Jacobs, RE
    PROGRESS IN NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY, 2002, 40 (04) : 275 - 306
  • [45] High-resolution small field-of-view magnetic resonance image acquisition system using a small planar coil and a pneumatic manipulator in an open MRI scanner
    Miki, Kohei
    Masamune, Ken
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (10) : 1687 - 1697
  • [46] A coil system for real-time magnetic fluid hyperthermia microscopy studies
    Subramanian, Mahendran
    Miaskowski, Arkadiusz
    Pearce, Gillian
    Dobson, Jon
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2016, 32 (02) : 112 - 120
  • [47] High-resolution small field-of-view magnetic resonance image acquisition system using a small planar coil and a pneumatic manipulator in an open MRI scanner
    Kohei Miki
    Ken Masamune
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 1687 - 1697
  • [48] Design of a four-coil surface array magnetic resonance microscopy at for in vivo 600 MHz
    Zhang, XZ
    Webb, A
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2005, 24B (01) : 6 - 14
  • [49] Design and fabriacation of a three-axis multilayer gradient coil for magnetic resonance microscopy of mice
    Blaine Chronik
    Andrew Alejski
    Brian K. Rutt
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2000, 10 (2) : 131 - 146
  • [50] Design and fabrication of a three-axis multilayer gradient coil for magnetic resonance microscopy of mice
    Chronik, Blaine
    Alejski, Andrew
    Rutt, Brian K.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2000, 10 (02) : 131 - 146