A magnetic resonance (MR) microscopy system using a microfluidically cryo-cooled planar coil

被引:10
|
作者
Koo, Chiwan [1 ]
Godley, Richard F. [2 ]
Park, Jaewon [2 ]
McDougall, Mary P. [1 ,2 ]
Wright, Steven M. [1 ,2 ]
Han, Arum [1 ,2 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX 77843 USA
基金
美国国家卫生研究院;
关键词
MICROPUMP; PERFORMANCE; VLSI;
D O I
10.1039/c1lc20056a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present the development of a microfluidically cryo-cooled planar coil for magnetic resonance (MR) microscopy. Cryogenically cooling radiofrequency (RF) coils for magnetic resonance imaging (MRI) can improve the signal to noise ratio (SNR) of the experiment. Conventional cryostats typically use a vacuum gap to keep samples to be imaged, especially biological samples, at or near room temperature during cryo-cooling. This limits how close a cryo-cooled coil can be placed to the sample. At the same time, a small coil-to-sample distance significantly improves the MR imaging capability due to the limited imaging depth of planar MR microcoils. These two conflicting requirements pose challenges to the use of cryo-cooling in MR microcoils. The use of a microfluidic based cryostat for localized cryo-cooling of MR microcoils is a step towards eliminating these constraints. The system presented here consists of planar receive-only coils with integrated cryo-cooling microfluidic channels underneath, and an imaging surface on top of the planar coils separated by a thin nitrogen gas gap. Polymer microfluidic channel structures fabricated through soft lithography processes were used to flow liquid nitrogen under the coils in order to cryo-cool the planar coils to liquid nitrogen temperature (-196 degrees C). Two unique features of the cryo-cooling system minimize the distance between the coil and the sample: (1) the small dimension of the polymer microfluidic channel enables localized cooling of the planar coils, while minimizing thermal effects on the nearby imaging surface. (2) The imaging surface is separated from the cryo-cooled planar coil by a thin gap through which nitrogen gas flows to thermally insulate the imaging surface, keeping it above 0 degrees C and preventing potential damage to biological samples. The localized cooling effect was validated by simulations, bench testing, and MR imaging experiments. Using this cryo-cooled planar coil system inside a 4.7 Tesla MR system resulted in an average image SNR enhancement of 1.47 +/- 0.11 times relative to similar room-temperature coils.
引用
下载
收藏
页码:2197 / 2203
页数:7
相关论文
共 50 条
  • [21] Design of a superconducting volume coil for magnetic resonance microscopy of the mouse brain
    Nouls, John C.
    Izenson, Michael G.
    Greeley, Harold P.
    Johnson, G. Allan
    JOURNAL OF MAGNETIC RESONANCE, 2008, 191 (02) : 231 - 238
  • [22] Magnetic resonance microscopy for submillimeter samples in a horizontal MR scanner
    Thomas Hüfken
    Tobias Lobmeyer
    Bernd Gahr
    Fabian Bschorr
    Tobias Speidel
    Steffen Just
    Volker Rasche
    Scientific Reports, 14 (1)
  • [23] Planar coil system consisting of three coil pairs for producing a uniform magnetic field
    Sasada, I
    Nakashima, Y
    JOURNAL OF APPLIED PHYSICS, 2006, 99 (08)
  • [24] Planar coil system consisting of three coil pairs for producing a uniform magnetic field
    Sasada, I.
    Nakashima, Y.
    Journal of Applied Physics, 2006, 99 (08):
  • [25] MR mammary ductography using a microscopy coil for assessment of intraductal lesions
    Kanemaki, Y
    Kurihara, Y
    Itoh, D
    Kamijo, K
    Nakajima, Y
    Fukuda, M
    Van Cauteren, M
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (05) : 1340 - 1342
  • [26] A New Planar Single-Channel Shim Coil Using Multiple Circular Currents for Magnetic Resonance Imaging
    Tamada, Daiki
    Kose, Katsumi
    Haishi, Tomoyuki
    APPLIED PHYSICS EXPRESS, 2012, 5 (05)
  • [27] Multilayered receive coil produced using a non-planar photofabrication process for an intraluminal magnetic resonance imaging
    Matsunaga, T.
    Matsuoka, Y.
    Ichimura, S.
    Wei, Q.
    Kuroda, K.
    Kato, Z.
    Esashi, M.
    Haga, Y.
    SENSORS AND ACTUATORS A-PHYSICAL, 2017, 261 : 130 - 139
  • [28] NONINVASIVE TUMOR VOLUME MEASUREMENT USING MAGNETIC-RESONANCE (MR) IMAGING AND AN OPEN SIDED SADDLE COIL
    VALENTINE, JL
    YAMANASHI, WS
    PATIL, AA
    PAULSEN, R
    HILL, DL
    LESTER, PD
    FILIP, OF
    PHYSIOLOGICAL CHEMISTRY AND PHYSICS AND MEDICAL NMR, 1986, 18 (02) : 103 - 108
  • [29] Narrowband magnetic nanoparticle imaging using cooled pickup coil and gradient field
    Enpuku, Keiji
    Miyazaki, Takashi
    Morishita, Manabu
    Tsujita, Yuya
    Matsuo, Masaaki
    Bai, Shi
    Sasayama, Teruyoshi
    Yoshida, Takashi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2015, 54 (05)
  • [30] Planar-coil-based Micro-detection in Nuclear Magnetic Resonance Spectroscopy
    Li, Xiaonan
    Liu, Guoqiang
    Li, Shiqiang
    Xia, Hui
    Wang, Yong
    2018 5TH INTERNATIONAL CONFERENCE ON SYSTEMS AND INFORMATICS (ICSAI), 2018, : 895 - 899