A magnetic resonance (MR) microscopy system using a microfluidically cryo-cooled planar coil

被引:10
|
作者
Koo, Chiwan [1 ]
Godley, Richard F. [2 ]
Park, Jaewon [2 ]
McDougall, Mary P. [1 ,2 ]
Wright, Steven M. [1 ,2 ]
Han, Arum [1 ,2 ]
机构
[1] Texas A&M Univ, Dept Biomed Engn, College Stn, TX 77843 USA
[2] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX 77843 USA
基金
美国国家卫生研究院;
关键词
MICROPUMP; PERFORMANCE; VLSI;
D O I
10.1039/c1lc20056a
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present the development of a microfluidically cryo-cooled planar coil for magnetic resonance (MR) microscopy. Cryogenically cooling radiofrequency (RF) coils for magnetic resonance imaging (MRI) can improve the signal to noise ratio (SNR) of the experiment. Conventional cryostats typically use a vacuum gap to keep samples to be imaged, especially biological samples, at or near room temperature during cryo-cooling. This limits how close a cryo-cooled coil can be placed to the sample. At the same time, a small coil-to-sample distance significantly improves the MR imaging capability due to the limited imaging depth of planar MR microcoils. These two conflicting requirements pose challenges to the use of cryo-cooling in MR microcoils. The use of a microfluidic based cryostat for localized cryo-cooling of MR microcoils is a step towards eliminating these constraints. The system presented here consists of planar receive-only coils with integrated cryo-cooling microfluidic channels underneath, and an imaging surface on top of the planar coils separated by a thin nitrogen gas gap. Polymer microfluidic channel structures fabricated through soft lithography processes were used to flow liquid nitrogen under the coils in order to cryo-cool the planar coils to liquid nitrogen temperature (-196 degrees C). Two unique features of the cryo-cooling system minimize the distance between the coil and the sample: (1) the small dimension of the polymer microfluidic channel enables localized cooling of the planar coils, while minimizing thermal effects on the nearby imaging surface. (2) The imaging surface is separated from the cryo-cooled planar coil by a thin gap through which nitrogen gas flows to thermally insulate the imaging surface, keeping it above 0 degrees C and preventing potential damage to biological samples. The localized cooling effect was validated by simulations, bench testing, and MR imaging experiments. Using this cryo-cooled planar coil system inside a 4.7 Tesla MR system resulted in an average image SNR enhancement of 1.47 +/- 0.11 times relative to similar room-temperature coils.
引用
下载
收藏
页码:2197 / 2203
页数:7
相关论文
共 50 条
  • [1] AN INTEGRATED MICROFLUIDIC CRYO-COOLED PLANAR COIL SYSTEM FOR MAGNETIC RESONANCE IMAGING (MRI)
    Koo, Chiwan
    Feng, Ke
    Park, Jaewon
    McDougall, Mary P.
    Wright, Steven M.
    Han, Arum
    MEMS 2010: 23RD IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS, TECHNICAL DIGEST, 2010, : 1011 - 1014
  • [2] Anisotropic plasma etching of polymers using a cryo-cooled resist mask
    Schüppert, B
    Brose, E
    Petermann, K
    Moosburger, R
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 2000, 18 (02): : 385 - 387
  • [3] Development of a cryo-cooled superconducting magnet with a large magnetic-force field
    Kyoto, M
    Hanai, S
    Takano, H
    Takahashi, K
    Nishijima, G
    Awaji, S
    Watanabe, K
    Motokawa, A
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2004, 14 (02) : 384 - 387
  • [4] A Cryo-Cooled Scanning SQUID Microscope for Imaging High-Frequency Magnetic Fields
    Vlahacos, C. P.
    Matthews, J.
    Wellstood, F. C.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 412 - 415
  • [5] First studies towards a cryo-cooled Phased Array Radar System for Space Surveillance
    Ben Bekhti, N.
    Froehlich, A.
    Grenz, O.
    Koenig, F.
    Naumann, L.
    Putselyk, S.
    Rahlf, F.
    Tiesing, M.
    Wirths, T.
    Wilden, H.
    27TH INTERNATIONAL CRYOGENICS ENGINEERING CONFERENCE AND INTERNATIONAL CRYOGENIC MATERIALS CONFERENCE 2018 (ICEC-ICMC 2018), 2019, 502
  • [6] Technical aspects: Development, manufacture and installation of a cryo-cooled HTS coil system for high-resolution in-vivo imaging of the mouse at 1.5 T
    Ginefri, Jean-Christophe
    Poirier-Quinot, Marie
    Girard, Olivier
    Darrasse, Luc
    METHODS, 2007, 43 (01) : 54 - 67
  • [7] Performances of compact magnetic field generators using cryo-cooled high temperature bulk superconductors as quasi-permanent magnets
    Oka, T.
    Hirose, Y.
    Kanayama, H.
    Kikuchi, H.
    Fukui, S.
    Ogawa, J.
    Sato, T.
    Yamaguchi, M.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2007, 20 (12): : 1233 - 1238
  • [8] High-sensitivity cooled coil system for nuclear magnetic resonance in kHz range
    Lin, Tingting
    Zhang, Yi
    Lee, Yong-Ho
    Krause, Hans-Joachim
    Lin, Jun
    Zhao, Jing
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (11):
  • [9] An automated system to mount cryo-cooled protein crystals on a synchrotron beamline, using compact sample cassettes and a small-scale robot
    Cohen, AE
    Ellis, PJ
    Miller, MD
    Deacon, AM
    Phizackerley, RP
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2002, 35 : 720 - 726
  • [10] Compactly Composed Strong Magnetic Field Generators with Cryo-cooled High Temperature Bulk Superconductors as Quasi-Permanent Magnets
    Oka, T.
    Hirose, Y.
    Kanayama, H.
    Kikuchi, H.
    Ogawa, J.
    Fukui, S.
    Sato, T.
    Yamaguchi, M.
    8TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'07), 2008, 97