A hybrid vibration mitigation method based on the crowd flow control and tuned mass damper on a footbridge

被引:13
|
作者
Zhu, Qiankun [1 ,2 ]
Yang, Wenbin [1 ]
Zhang, Qiong [1 ,2 ]
Du, Yongfeng [1 ,2 ]
机构
[1] Lanzhou Univ Technol, Inst Earthquake Protect & Disaster Mitigat, Lanzhou 730050, Peoples R China
[2] Lanzhou Univ Technol, Western Ctr Disaster Mitigat Civil Engn, Minist Educ, Lanzhou 730050, Peoples R China
基金
中国国家自然科学基金;
关键词
Social force model; Hybrid mitigation method; Time-varying coupling model; Input energy; Vibration mitigation rate; SOCIAL FORCE MODEL; BRIDGE DYNAMIC INTERACTION; INDUCED LATERAL VIBRATIONS; SERVICEABILITY;
D O I
10.1016/j.engstruct.2021.112972
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study proposes a hybrid mitigation method based on the crowd flow control and the eddy current tuned mass damper to control the excessive vibration caused by the random crowd excitation. The vibration mitigation method is applied on an experimental footbridge under random crowd loads and then the mitigation performance is analyzed experimentally and numerically. The numerical method of the social force model is used to simulate pedestrians detour behaviour in a blocking scenario. The time-varying coupling model of the crowd structure-tuned mass damper is established, and the structure response is investigated. A virtual three dimensional obstacle based on the pedestrian stereo vision on the laboratory footbridge is designed to avoid the accident that pedestrians may encounter caused by the actual obstacles. It was found that the numerical response is in an appropriate agreement with the experimental data, implying that the social force model can simulate the detour behaviour accurately. Finally, the mitigation strategies are numerically implemented on an indoor footbridge, and the factors influencing the vibration mitigation rate are further analyzed using three different layouts. The layouts include Layout 1, for forcing pedestrian diversion separation, and Layout 2, for generating a bottle neck effect, and Layout 3, a nonlinear layout mode of obstacles, which is a combination of Layouts 1 and 2. The results show that the performance of the proposed hybrid mitigation method is more effective than the single mitigation method. In addition, the results show that the number and layout of obstacles determine the mitigation efficiency. It was also found that the vibration mitigation rate of the hybrid method with Layout 3 increases with the crowd density and tends to be stable when the crowd density exceeds 0.92 ped./m(2). In addition, the mixed layout scheme may have more advantages in controlling crowd motion under high crowd density, while the linear layout schemes have certain competitiveness under low crowd density.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Application of an Eddy Current-Tuned Mass Damper to Vibration Mitigation of Offshore Wind Turbines
    Lian, Jijian
    Zhao, Yue
    Lian, Chong
    Wang, Haijun
    Dong, Xiaofeng
    Jiang, Qi
    Zhou, Huan
    Jiang, Junni
    ENERGIES, 2018, 11 (12)
  • [42] A Multi-Degree of Freedom Tuned Mass Damper Design for Vibration Mitigation of a Suspension Bridge
    Meng, Fanhao
    Wan, Jiancheng
    Xia, Yongjun
    Ma, Yong
    Yu, Jingjun
    APPLIED SCIENCES-BASEL, 2020, 10 (02):
  • [43] Vibration mitigation of Shazand Railway Bridge induced by train using tuned mass damper (TMD)
    School of Civil Engineering, Shiraz University of Technology, Shiraz, Iran
    不详
    Period Polytech Mech Eng, 4 (189-198):
  • [44] Design and implementation of two-degree-of-freedom tuned mass damper in milling vibration mitigation
    Yang, Yiqing
    Dai, Wei
    Liu, Qiang
    JOURNAL OF SOUND AND VIBRATION, 2015, 335 : 78 - 88
  • [45] Vibration control of structure using active tuned mass damper: A new control algorithm
    Safakhaneh, Motasam Mousaviyan
    Farzam, Maziar Fahimi
    Ahmadi, Hamzeh
    Farnam, Arash
    JOURNAL OF VIBRATION AND CONTROL, 2024,
  • [46] Seismic Vibration Mitigation of a Cable-Stayed Bridge with Asymmetric Pounding Tuned Mass Damper
    Zhang, Peng
    Tan, Jie
    Liu, Haitao
    Yang, Gang
    Cui, Chunyi
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2021, 2021
  • [47] Footbridge Serviceability Analysis: From System Identification to Tuned Mass Damper Implementation
    Qin, Shiqiang
    Zhou, Yun-Lai
    Kang, Juntao
    KSCE JOURNAL OF CIVIL ENGINEERING, 2019, 23 (02) : 754 - 762
  • [48] Design on vibration control of TV tower by pendulous tank as tuned mass damper
    Gao, Xianfeng
    Ma, Penle
    He, Minjuan
    Tongji Daxue Xuebao/Journal of Tongji University, 1999, 27 (03): : 268 - 272
  • [49] Experimental investigation of vibration attenuation using nonlinear tuned mass damper and pendulum tuned mass damper in parallel
    Sun, C.
    Nagarajaiah, S.
    Dick, A. J.
    NONLINEAR DYNAMICS, 2014, 78 (04) : 2699 - 2715
  • [50] Design of the symmetric tuned mass damper for torsional vibration control of the rotating shaft
    Nguyen, Duy-Chinh
    Nguyen, Duy-Chinh (duychinhdhspkthy@gmail.com), 1600, SAGE Publications Inc. (52): : 7 - 8