A hybrid vibration mitigation method based on the crowd flow control and tuned mass damper on a footbridge

被引:13
|
作者
Zhu, Qiankun [1 ,2 ]
Yang, Wenbin [1 ]
Zhang, Qiong [1 ,2 ]
Du, Yongfeng [1 ,2 ]
机构
[1] Lanzhou Univ Technol, Inst Earthquake Protect & Disaster Mitigat, Lanzhou 730050, Peoples R China
[2] Lanzhou Univ Technol, Western Ctr Disaster Mitigat Civil Engn, Minist Educ, Lanzhou 730050, Peoples R China
基金
中国国家自然科学基金;
关键词
Social force model; Hybrid mitigation method; Time-varying coupling model; Input energy; Vibration mitigation rate; SOCIAL FORCE MODEL; BRIDGE DYNAMIC INTERACTION; INDUCED LATERAL VIBRATIONS; SERVICEABILITY;
D O I
10.1016/j.engstruct.2021.112972
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This study proposes a hybrid mitigation method based on the crowd flow control and the eddy current tuned mass damper to control the excessive vibration caused by the random crowd excitation. The vibration mitigation method is applied on an experimental footbridge under random crowd loads and then the mitigation performance is analyzed experimentally and numerically. The numerical method of the social force model is used to simulate pedestrians detour behaviour in a blocking scenario. The time-varying coupling model of the crowd structure-tuned mass damper is established, and the structure response is investigated. A virtual three dimensional obstacle based on the pedestrian stereo vision on the laboratory footbridge is designed to avoid the accident that pedestrians may encounter caused by the actual obstacles. It was found that the numerical response is in an appropriate agreement with the experimental data, implying that the social force model can simulate the detour behaviour accurately. Finally, the mitigation strategies are numerically implemented on an indoor footbridge, and the factors influencing the vibration mitigation rate are further analyzed using three different layouts. The layouts include Layout 1, for forcing pedestrian diversion separation, and Layout 2, for generating a bottle neck effect, and Layout 3, a nonlinear layout mode of obstacles, which is a combination of Layouts 1 and 2. The results show that the performance of the proposed hybrid mitigation method is more effective than the single mitigation method. In addition, the results show that the number and layout of obstacles determine the mitigation efficiency. It was also found that the vibration mitigation rate of the hybrid method with Layout 3 increases with the crowd density and tends to be stable when the crowd density exceeds 0.92 ped./m(2). In addition, the mixed layout scheme may have more advantages in controlling crowd motion under high crowd density, while the linear layout schemes have certain competitiveness under low crowd density.
引用
收藏
页数:21
相关论文
共 50 条
  • [21] Analysis of Flow-Induced Vibration Control in a Pontoon Carrier Based on a Pendulum-Tuned Mass Damper
    Du, Libin
    Cui, Yongchao
    Ma, Yanqun
    Liu, Jie
    Liu, Zezheng
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2023, 11 (10)
  • [22] Vibration control of a slender footbridge using passive and semiactive tuned mass dampers
    Moutinho, C.
    Cunha, A.
    Caetano, E.
    de Carvalho, J. M.
    STRUCTURAL CONTROL & HEALTH MONITORING, 2018, 25 (09):
  • [23] Development and Vibration Control of Frequency Adjustable Tuned Mass Damper Based on Magnetorheological Elastomer
    Zhang, Jiarui
    Zhu, Yaoyang
    Tu, Jianwei
    Li, Zhao
    Wang, Qiankun
    MATERIALS, 2022, 15 (05)
  • [24] A numerical study of hybrid tuned mass damper and tuned liquid damper system on structure motion control
    Hsieh, Meng-Chang
    Huang, Guan-Lee
    Liu, Haijun
    Chen, Shih-Jiun
    Chen, Bang-Fuh
    OCEAN ENGINEERING, 2021, 242
  • [25] Cables interconnected with tuned inerter damper for vibration mitigation
    Sun, Limin
    Hong, Dongxiao
    Chen, Lin
    ENGINEERING STRUCTURES, 2017, 151 : 57 - 67
  • [26] A piezoelectric tuned mass damper for simultaneous vibration control and energy harvesting
    Sheng, Weiqiang
    Xiang, Hongjun
    SMART MATERIALS AND STRUCTURES, 2024, 33 (01)
  • [27] Vibration control of a Stirling engine with an electromagnetic active tuned mass damper
    Hassan, Ali
    Torres-Perez, Angel
    Kaczmarczyk, Stefan
    Picton, Phil
    CONTROL ENGINEERING PRACTICE, 2016, 51 : 108 - 120
  • [28] Vibration Control of a Pipeline Structure Using Pounding Tuned Mass Damper
    Song, G. B.
    Zhang, P.
    Li, L. Y.
    Singla, M.
    Patil, D.
    Li, H. N.
    Mo, Y. L.
    JOURNAL OF ENGINEERING MECHANICS, 2016, 142 (06)
  • [29] Multiple Tuned Mass Damper Based Vibration Mitigation of Offshore Wind Turbine Considering Soil–Structure Interaction
    Mosaruf HUSSAN
    Faria SHARMIN
    Dookie KIM
    China Ocean Engineering, 2017, 31 (04) : 476 - 486
  • [30] Multiple tuned mass damper based vibration mitigation of offshore wind turbine considering soil–structure interaction
    Mosaruf Hussan
    Faria Sharmin
    Dookie Kim
    China Ocean Engineering, 2017, 31 : 476 - 486