Electromyographic endotracheal tube placement during thyroid surgery in neuromonitoring of recurrent laryngeal nerve

被引:53
|
作者
Tsai, Cheng-Jing [1 ]
Tseng, Kuang-Yi [1 ]
Wang, Fu-Yuan [1 ]
Lu, I-Cheng [1 ,2 ]
Wang, Hsun-Mo [3 ]
Wu, Che-Wei [4 ,5 ]
Chiang, Hui-Ching [6 ]
Chiang, Feng-Yu [7 ,8 ]
机构
[1] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Anesthesiol, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Coll Med, Fac Med, Dept Anesthesiol, Kaohsiung, Taiwan
[3] Kaohsiung Municipal Tatung Hosp, Dept Otolaryngol, Kaohsiung, Taiwan
[4] Kaohsiung Med Univ, Grad Inst Clin Med, Kaohsiung, Taiwan
[5] Kaohsiung Municipal Hsiaokang Hosp, Dept Otolaryngol, Kaohsiung, Taiwan
[6] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Nursing, Kaohsiung, Taiwan
[7] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Otolaryngol, Kaohsiung, Taiwan
[8] Kaohsiung Med Univ, Coll Med, Fac Med, Dept Otolaryngol, Kaohsiung, Taiwan
来源
KAOHSIUNG JOURNAL OF MEDICAL SCIENCES | 2011年 / 27卷 / 03期
关键词
EMG endotracheal tube; Endotracheal tube displacement; Intraoperative neuromonitoring; Thyroid surgery; PITFALLS; INJURY; PLAUDITS; RISK;
D O I
10.1016/j.kjms.2010.08.002
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Intraoperative neuromonitoring (IONM) is widely used in thyroid surgery. This study aimed to investigate the influence of neck extension on electromyographic (EMG) endotracheal tube displacement and to determine the necessity of routinely checking the final electrode position after the patient had been fully positioned. A consecutive 220 patients undergoing thyroidectomy were enrolled. All patients were intubated with the EMG endotracheal tube under direct laryngoscopy. The electrode position and tube displacement were routinely checked and measured by laryngofiberoscopy before and after patient positioning. The patients were divided into two groups. In Group I (n=110), the EMG tube was taped and fixed to the right mouth angle before full neck extension. In Group II (n=110), the EMG tube was disconnected from the circuit tube and was not taped until full neck extension. In all patients, we ensured that the final electrode position was the optimal position with laryngofiberoscopic examination. The tube displacement after neck extension ranged from 16 mm upward to 4 mm downward in Group I and from 12 mm upward to 5 mm downward in Group II. The rate of tube displacement greater than 10 mm was 12.7% in Group I and 3.6% in Group II. Successful monitoring was achieved in all patients after the final optimal position of electrodes was ensured routinely. The electrode position can be severely displaced after the patient has been fully positioned. Verification of ideal position of electrodes before the beginning of the operation is a necessary step to guarantee functional intraoperative neuromonitoring. (sic) Copyright (C) 2011, Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [31] THE RECURRENT LARYNGEAL NERVE IN THYROID SURGERY
    O'Neill, J. P.
    Fenton, J. E.
    SURGEON-JOURNAL OF THE ROYAL COLLEGES OF SURGEONS OF EDINBURGH AND IRELAND, 2008, 6 (06): : 373 - 377
  • [32] Changes in Tracheal Tube Cuff Pressure and Recurrent Laryngeal Nerve Conductivity During Thyroid Surgery
    Taylor, James W.
    Soeyland, Kathleen
    Ball, Christine
    Lee, James C.
    Serpell, Jonathan
    WORLD JOURNAL OF SURGERY, 2020, 44 (02) : 328 - 333
  • [33] Changes in Tracheal Tube Cuff Pressure and Recurrent Laryngeal Nerve Conductivity During Thyroid Surgery
    James W. Taylor
    Kathleen Soeyland
    Christine Ball
    James C. Lee
    Jonathan Serpell
    World Journal of Surgery, 2020, 44 : 328 - 333
  • [34] Intraoperative electromyographic monitoring of the, recurrent laryngeal nerve in reoperative thyroid and parathyroid surgery - Discussion
    Shaha, AR
    Dralle, H
    Yarbrough
    Dackiw, APB
    Snyder, SK
    Kasperbauer
    Doherty, GM
    SURGERY, 2004, 136 (06) : 1114 - 1115
  • [35] Thyroid surgery and the recurrent laryngeal nerve
    Agarwal, A
    Agarwal, G
    Mishra, SK
    BRITISH JOURNAL OF SURGERY, 1999, 86 (11) : 1479 - 1479
  • [36] Thyroid surgery and the recurrent laryngeal nerve
    Wheeler, MH
    BRITISH JOURNAL OF SURGERY, 1999, 86 (03) : 291 - 292
  • [37] Intraoperative neuromonitoring in thyroid surgery?: A complementary tool to the systematic intraoperative identification of the recurrent laryngeal nerve
    Kern, B.
    Kramer, E.
    Peterli, R.
    von Fluee, M.
    BRITISH JOURNAL OF SURGERY, 2007, 94 (06) : 771 - 771
  • [38] Recurrent laryngeal nerve monitoring during thyroid surgery in childhood
    Meyer, T.
    Hoecht, B.
    EUROPEAN JOURNAL OF PEDIATRIC SURGERY, 2006, 16 (03) : 149 - 154
  • [39] RECURRENT LARYNGEAL NERVE - IDENTIFICATION DURING THYROID AND PARATHYROID SURGERY
    GAVILAN, J
    GAVILAN, C
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1986, 112 (12) : 1286 - 1288
  • [40] Assessment of recurrent laryngeal nerve function during thyroid surgery
    Smith, J.
    Douglas, J.
    Smith, B.
    Dougherty, T.
    Ayshford, C.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2014, 96 (02) : 130 - 135