Electromyographic endotracheal tube placement during thyroid surgery in neuromonitoring of recurrent laryngeal nerve

被引:53
|
作者
Tsai, Cheng-Jing [1 ]
Tseng, Kuang-Yi [1 ]
Wang, Fu-Yuan [1 ]
Lu, I-Cheng [1 ,2 ]
Wang, Hsun-Mo [3 ]
Wu, Che-Wei [4 ,5 ]
Chiang, Hui-Ching [6 ]
Chiang, Feng-Yu [7 ,8 ]
机构
[1] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Anesthesiol, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Coll Med, Fac Med, Dept Anesthesiol, Kaohsiung, Taiwan
[3] Kaohsiung Municipal Tatung Hosp, Dept Otolaryngol, Kaohsiung, Taiwan
[4] Kaohsiung Med Univ, Grad Inst Clin Med, Kaohsiung, Taiwan
[5] Kaohsiung Municipal Hsiaokang Hosp, Dept Otolaryngol, Kaohsiung, Taiwan
[6] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Nursing, Kaohsiung, Taiwan
[7] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Otolaryngol, Kaohsiung, Taiwan
[8] Kaohsiung Med Univ, Coll Med, Fac Med, Dept Otolaryngol, Kaohsiung, Taiwan
来源
KAOHSIUNG JOURNAL OF MEDICAL SCIENCES | 2011年 / 27卷 / 03期
关键词
EMG endotracheal tube; Endotracheal tube displacement; Intraoperative neuromonitoring; Thyroid surgery; PITFALLS; INJURY; PLAUDITS; RISK;
D O I
10.1016/j.kjms.2010.08.002
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Intraoperative neuromonitoring (IONM) is widely used in thyroid surgery. This study aimed to investigate the influence of neck extension on electromyographic (EMG) endotracheal tube displacement and to determine the necessity of routinely checking the final electrode position after the patient had been fully positioned. A consecutive 220 patients undergoing thyroidectomy were enrolled. All patients were intubated with the EMG endotracheal tube under direct laryngoscopy. The electrode position and tube displacement were routinely checked and measured by laryngofiberoscopy before and after patient positioning. The patients were divided into two groups. In Group I (n=110), the EMG tube was taped and fixed to the right mouth angle before full neck extension. In Group II (n=110), the EMG tube was disconnected from the circuit tube and was not taped until full neck extension. In all patients, we ensured that the final electrode position was the optimal position with laryngofiberoscopic examination. The tube displacement after neck extension ranged from 16 mm upward to 4 mm downward in Group I and from 12 mm upward to 5 mm downward in Group II. The rate of tube displacement greater than 10 mm was 12.7% in Group I and 3.6% in Group II. Successful monitoring was achieved in all patients after the final optimal position of electrodes was ensured routinely. The electrode position can be severely displaced after the patient has been fully positioned. Verification of ideal position of electrodes before the beginning of the operation is a necessary step to guarantee functional intraoperative neuromonitoring. (sic) Copyright (C) 2011, Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [21] Comparison of a Handheld Device vs Endotracheal Tube-Based Neuromonitoring for Recurrent Laryngeal Nerve Stimulation
    Kong, Derek Kai
    Kong, Amanda M.
    Chai, Raymond L.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2022, 166 (02) : 260 - 266
  • [22] Vagal nerve stimulation without dissecting the carotid sheath during intraoperative neuromonitoring of the recurrent laryngeal nerve in thyroid surgery
    Wu, Che-Wei
    Dionigi, Gianlorenzo
    Chen, Hui-Chun
    Chen, Hsiu-Ya
    Lee, Ka-Wo
    Lu, I-Cheng
    Chang, Pi-Ying
    Hsiao, Pi-Jung
    Ho, Kuen-Yao
    Chiang, Feng-Yu
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2013, 35 (10): : 1443 - 1447
  • [23] Comparison of various methods of electromyographic monitoring of the recurrent laryngeal nerve in thyroid surgery
    Tschopp, KP
    Gottardo, C
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2002, 111 (09): : 811 - 816
  • [24] Intraoperative electromyographic monitoring of the, recurrent laryngeal nerve in reoperative thyroid and parathyroid surgery
    Yarbrough, DE
    Thompson, GB
    Kasperbauer, JL
    Harper, CM
    Grant, CS
    SURGERY, 2004, 136 (06) : 1107 - 1114
  • [25] Demonstration of the recurrent laryngeal nerve during thyroid surgery
    Wienke, A.
    Janke, K.
    LARYNGO-RHINO-OTOLOGIE, 2007, 86 (08) : 595 - 596
  • [26] Role of Intraoperative Neuromonitoring of the Recurrent Laryngeal Nerve in High-Risk Thyroid Surgery
    Atallah, Ihab
    Dupret, Agnes
    Carpentier, Anne-Sophie
    Weingertner, Anne Sophie
    Volkmar, Pierre-Philippe
    Rodier, Jean-Francois
    JOURNAL OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2009, 38 (06): : 613 - 618
  • [27] Standardization of Intraoperative Neuromonitoring of Recurrent Laryngeal Nerve in Thyroid Operation
    Chiang, Feng-Yu
    Lee, Ka-Wo
    Chen, Hui-Chun
    Chen, Hsiu-Ya
    Lu, I-Cheng
    Kuo, Wen-Rei
    Hsieh, Ming-Chia
    Wu, Che-Wei
    WORLD JOURNAL OF SURGERY, 2010, 34 (02) : 223 - 229
  • [28] ANATOMICAL VARIATIONS OF RECURRENT LARYNGEAL NERVE DURING THYROID SURGERY: How TO IDENTIFY AND HANDLE THE VARIATIONS WITH INTRAOPERATIVE NEUROMONITORING
    Chiang, Feng-Yu
    Lu, I-Cheng
    Chen, Hui-Chun
    Chen, Hsiu-Ya
    Tsai, Cheng-Jing
    Hsiao, Pi-Jung
    Lee, Ka-Wo
    Wu, Che-Wei
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2010, 26 (11): : 575 - 583
  • [29] Standardization of Intraoperative Neuromonitoring of Recurrent Laryngeal Nerve in Thyroid Operation
    Feng-Yu Chiang
    Ka-Wo Lee
    Hui-Chun Chen
    Hsiu-Ya Chen
    I-Cheng Lu
    Wen-Rei Kuo
    Ming-Chia Hsieh
    Che-Wei Wu
    World Journal of Surgery, 2010, 34 : 223 - 229
  • [30] A New Era of Intraoperative Neuromonitoring: Beyond the Electromyography Endotracheal Tube During Thyroid Surgery
    Shin, Sung-Chan
    Lee, Byung-Joo
    CLINICAL AND EXPERIMENTAL OTORHINOLARYNGOLOGY, 2020, 13 (04) : 324 - 325