Electromyographic endotracheal tube placement during thyroid surgery in neuromonitoring of recurrent laryngeal nerve

被引:53
|
作者
Tsai, Cheng-Jing [1 ]
Tseng, Kuang-Yi [1 ]
Wang, Fu-Yuan [1 ]
Lu, I-Cheng [1 ,2 ]
Wang, Hsun-Mo [3 ]
Wu, Che-Wei [4 ,5 ]
Chiang, Hui-Ching [6 ]
Chiang, Feng-Yu [7 ,8 ]
机构
[1] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Anesthesiol, Kaohsiung, Taiwan
[2] Kaohsiung Med Univ, Coll Med, Fac Med, Dept Anesthesiol, Kaohsiung, Taiwan
[3] Kaohsiung Municipal Tatung Hosp, Dept Otolaryngol, Kaohsiung, Taiwan
[4] Kaohsiung Med Univ, Grad Inst Clin Med, Kaohsiung, Taiwan
[5] Kaohsiung Municipal Hsiaokang Hosp, Dept Otolaryngol, Kaohsiung, Taiwan
[6] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Nursing, Kaohsiung, Taiwan
[7] Kaohsiung Med Univ, Kaohsiung Med Univ Hosp, Dept Otolaryngol, Kaohsiung, Taiwan
[8] Kaohsiung Med Univ, Coll Med, Fac Med, Dept Otolaryngol, Kaohsiung, Taiwan
来源
KAOHSIUNG JOURNAL OF MEDICAL SCIENCES | 2011年 / 27卷 / 03期
关键词
EMG endotracheal tube; Endotracheal tube displacement; Intraoperative neuromonitoring; Thyroid surgery; PITFALLS; INJURY; PLAUDITS; RISK;
D O I
10.1016/j.kjms.2010.08.002
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Intraoperative neuromonitoring (IONM) is widely used in thyroid surgery. This study aimed to investigate the influence of neck extension on electromyographic (EMG) endotracheal tube displacement and to determine the necessity of routinely checking the final electrode position after the patient had been fully positioned. A consecutive 220 patients undergoing thyroidectomy were enrolled. All patients were intubated with the EMG endotracheal tube under direct laryngoscopy. The electrode position and tube displacement were routinely checked and measured by laryngofiberoscopy before and after patient positioning. The patients were divided into two groups. In Group I (n=110), the EMG tube was taped and fixed to the right mouth angle before full neck extension. In Group II (n=110), the EMG tube was disconnected from the circuit tube and was not taped until full neck extension. In all patients, we ensured that the final electrode position was the optimal position with laryngofiberoscopic examination. The tube displacement after neck extension ranged from 16 mm upward to 4 mm downward in Group I and from 12 mm upward to 5 mm downward in Group II. The rate of tube displacement greater than 10 mm was 12.7% in Group I and 3.6% in Group II. Successful monitoring was achieved in all patients after the final optimal position of electrodes was ensured routinely. The electrode position can be severely displaced after the patient has been fully positioned. Verification of ideal position of electrodes before the beginning of the operation is a necessary step to guarantee functional intraoperative neuromonitoring. (sic) Copyright (C) 2011, Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:96 / 101
页数:6
相关论文
共 50 条
  • [1] Continuous Intraoperative Neuromonitoring of the Recurrent Laryngeal Nerve during Thyroid Surgery
    Jonas, J.
    ZENTRALBLATT FUR CHIRURGIE, 2010, 135 (03): : 273 - 276
  • [2] Practical comments on recurrent laryngeal nerve neuromonitoring during thyroid surgery
    Masiak-Segit, Wioletta
    Dabrowski, Andrzej
    Abramowicz, Krystyna
    Jaworski, Tomasz Jerzy
    Wallner, Grzegorz
    KARDIOCHIRURGIA I TORAKOCHIRURGIA POLSKA-POLISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 10 (04) : 374 - 379
  • [3] Monitoring of recurrent laryngeal nerve injury using an electromyographic endotracheal tube in thyroid and parathyroid surgery. Anesthetic aspects
    Martin Jaramago, J.
    Tamarit Conejeros, M.
    Escudero Torrella, M.
    Solaz Roldan, C.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2013, 60 (10): : 576 - 583
  • [4] PLACEMENT OF THE ELECTROMYOGRAPHIC ENDOTRACHEAL TUBE BY FIBEROPTIC BRONCHOSCOPE IN THYROID SURGERY
    Valencia, L.
    Sitges, A.
    Trillo, L.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2009, 56 (01): : 50 - 51
  • [5] Influence of intravenous anesthetics on neuromonitoring of the recurrent laryngeal nerve during thyroid surgery
    Chang, Pi-Ying
    Wu, Che-Wei
    Chen, Hsiu-Ya
    Chen, Hui-Chun
    Cheng, Kuang-I
    Lu, I-Cheng
    Chiang, Feng-Yu
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2014, 30 (10): : 499 - 503
  • [6] Influence of muscle relaxation on neuromonitoring of the recurrent laryngeal nerve during thyroid surgery
    Marusch, F
    Hussock, J
    Haring, G
    Hachenberg, T
    Gastinger, I
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 94 (05) : 596 - 600
  • [7] Intraoperative Neuromonitoring of the Recurrent Laryngeal Nerve in Robotic Thyroid Surgery
    Bae, Dong Sik
    Kim, Su-Jin
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2015, 25 (01): : 23 - 26
  • [8] Optimal depth of NIM EMG endotracheal tube for intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroidectomy
    Lu, I-Chen
    Chu, Koung-Shing
    Tsai, Cheng-Jing
    Wu, Che-Wei
    Kuo, Wen-Rei
    Chen, Hsiu-Ya
    Lee, Ka-Wo
    Chiang, Feng-Yu
    WORLD JOURNAL OF SURGERY, 2008, 32 (09) : 1935 - 1939
  • [9] Optimal Depth of NIM EMG Endotracheal Tube for Intraoperative Neuromonitoring of the Recurrent Laryngeal Nerve During Thyroidectomy
    I-Chen Lu
    Koung-Shing Chu
    Cheng-Jing Tsai
    Che-Wei Wu
    Wen-Rei Kuo
    Hsiu-Ya Chen
    Ka-Wo Lee
    Feng-Yu Chiang
    World Journal of Surgery, 2008, 32 : 1935 - 1939
  • [10] INTRAOPERATIVE NEUROMONITORING FOR EARLY LOCALIZATION AND IDENTIFICATION OF RECURRENT LARYNGEAL NERVE DURING THYROID SURGERY
    Chiang, Feng-Yu
    Lu, I-Cheng
    Chen, Hui-Chun
    Chen, Hsiu-Ya
    Tsai, Cheng-Jing
    Lee, Ka-Wo
    Hsiao, Pi-Jung
    Wu, Che-Wei
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2010, 26 (12): : 633 - 639