Fish detection at trash racks of large run-of-river power plants using an acoustic camera triplet

被引:3
|
作者
Schmidt, Marc [1 ]
Langkau, Manuel [1 ]
Zeyer, Marc [1 ]
Schletterer, Martin [2 ]
机构
[1] LFV Hydroakust GmbH, Sprakeler Str 409, D-48159 Munster, Germany
[2] Tiroler Wasserkraft AG TIWAG, Eduard Wallnofer Pl 2, A-6020 Innsbruck, Austria
关键词
SONAR;
D O I
10.1007/s35147-017-0209-y
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
Within the research project FIDET, imaging-sonars have been used at the trash rack of a large hydro-power plant in operation mode (catchment area 9 310 km(2), MQ = 293 m(3)/s, MJHQ = 1 187 m(3)/s) in the River Inn (Tyrol, Austria). Temporal and spatial-distributions of fishes were assessed with respect to flow rates and turbulence close to the rack. The results provide useful information on future actions to assist fish protection and downstream migration at the site. They also form the basis for further developments of existing sonar-based automatic detection and control systems to assist and monitor fish protection operations in real-time.
引用
收藏
页码:45 / 50
页数:6
相关论文
共 37 条
  • [31] Automatic detection, identification and counting of anguilliform fish using in situ acoustic camera data: Development of a cross-camera morphological analysis approach
    Le Quinio, Azenor
    De Oliveira, Eric
    Girard, Alexandre
    Guillard, Jean
    Roussel, Jean-Marc
    Zaoui, Fabrice
    Martignac, Francois
    PLOS ONE, 2023, 18 (02):
  • [32] Identifying high potential locations for run-of-the-river hydroelectric power plants using GIS and digital elevation models
    Zaidi, Arjumand Z.
    Khan, Majid
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 89 : 106 - 116
  • [33] Measuring fish length and assessing behaviour in a high-biodiversity reach of the Upper Yangtze River using an acoustic camera and echo sounder
    Lin, D. -Q.
    Zhang, H.
    Kang, M.
    Wei, Q. -W.
    JOURNAL OF APPLIED ICHTHYOLOGY, 2016, 32 (06) : 1072 - 1079
  • [34] Diadromous fish run assessment: a double-observer model using acoustic cameras to correct imperfect detection and improve population abundance estimates
    Boulenger, Clarisse
    Roussel, Jean-Marc
    Beaulaton, Laurent
    Martignac, Francois
    Nevoux, Marie
    FRONTIERS IN ECOLOGY AND EVOLUTION, 2024, 11
  • [35] Kombination klein- und großskaliger physikalischer Modellierung zur Optimierung der Spüleffizienz von LaufkraftwerkenCombination of small- and large-scale physical modelling to improve the flushing efficiency of Run-of-river hydropower plants
    Thomas Gold
    Kevin Reiterer
    Christoph Hauer
    Helmut Habersack
    Christine Sindelar
    Österreichische Wasser- und Abfallwirtschaft, 2024, 76 (3-4) : 133 - 141
  • [36] Acoustic thermography using an uncooled high speed camera and low power ultrasonic excitation:: test system and its application to impact flaw detection in CFRP
    Haupt, Lothar
    Zimmerhackl, Manfred
    Meyendorf, Norbert
    Koehler, Bernd
    ADVANCED SENSOR TECHNOLOGIES FOR NONDESTRUCTIVE EVALUATION AND STRUCTURAL HEALTH MONITORING II, 2006, 6179
  • [37] Grundlagen- und anwendungsorientierte experimentelle Forschung zu Stauraumverlandung und Remobilisierung bei Laufkraftwerken sowie Advektions- und Dispersionsprozessen von GeschiebeinputBasic and application-oriented experimental research on reservoir sedimentation and remobilization in run-of-river power plants as well as advection and dispersion processes of bedload input
    Christine Sindelar
    Kevin Reiterer
    Thomas Gold
    Johannes Schobesberger
    Petr Lichtneger
    Dominik Worf
    Christoph Hauer
    Helmut Habersack
    Österreichische Wasser- und Abfallwirtschaft, 2025, 77 (3) : 139 - 149