Motion Correction in Simultaneous PET/MR Brain Imaging Using Sparsely Sampled MR Navigators

被引:0
|
作者
Keller, S. H. [1 ]
Hansen, C. [1 ]
Hansen, C. [1 ]
Andersen, F. L. [1 ]
Ladefoged, C. [1 ]
Svarer, C. [2 ]
Kjaer, A. [1 ]
Hojgaard, L. [1 ]
Law, I. [1 ]
Henriksen, O. M. [1 ]
Hansen, A. E. [1 ]
机构
[1] Univ Copenhagen, Rigshosp, Dept Clin Physiol Nucl Med & PET, DK-2100 Copenhagen, Denmark
[2] Univ Copenhagen, Rigshosp, Neurobiol Res Unit, DK-2100 Copenhagen, Denmark
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
P186
引用
收藏
页码:S410 / S410
页数:1
相关论文
共 50 条
  • [21] MR-based correction of respiratory motion in oncological PET imaging using an integrated PET/MR system
    Wuerslin, Christian
    Schmidt, Holger
    Schwenzer, Nina
    Martirosian, Petros
    Claussen, Claus
    Stegger, Lars
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [22] PRACTICAL PET RESPIRATORY MOTION CORRECTION IN CLINICAL SIMULTANEOUS PET/MR
    Manber, Richard
    Atkinson, David
    Thielemans, Kris
    Hutton, Brian
    Barnes, Anna
    O'Meara, Celia
    Wan, Simon
    Ourselin, Sebastien
    Arridge, Simon
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1580 - 1583
  • [23] Using ITK to obtain motion transform in anatomically guided PET motion correction for simultaneous PET/MR
    Cheng, Ju-Chieh
    Laforest, Richard
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [24] Respiratory Motion Correction in Oncologic PET Using T1-Weighted MR Imaging on a Simultaneous Whole-Body PET/MR System
    Wuerslin, Christian
    Schmidt, Holger
    Martirosian, Petros
    Brendle, Cornelia
    Boss, Andreas
    Schwenzer, Nina F.
    Stegger, Lars
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (03) : 464 - 471
  • [25] Hybrid MR-guided and PET-guided motion correction of PET images in simultaneous PET/MR
    Feng, Tao
    Ahlman, Mark
    Tsui, Benjamin
    Guo, Liheng
    Guttman, Mike
    McVeigh, Elliot
    Bluemke, David
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [26] Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR
    Petibon, Yoann
    Guehl, Nicolas J.
    Reese, Timothy G.
    Ebrahimi, Behzad
    Normandin, Marc D.
    Shoup, Timothy M.
    Alpert, Nathaniel M.
    El Fakhri, Georges
    Ouyang, Jinsong
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02): : 326 - 343
  • [27] In-vivo studies of tagged MR based PET motion correction in simultaneous PET-MR
    Chun, Se Young
    Moussallem, Elie
    Reese, Timothy
    Guerin, Bastien
    Catana, Ciprian
    Alpert, Nathaniel
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [28] Assessment of motion correction strategies in simultaneous PET-MR
    Chun, Se Young
    Guerin, Bastien
    Cho, Sanghee
    Reese, Timothy
    Zhu, Xuping
    Ouyang, Jinsong
    Catana, Ciprian
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [29] Simultaneous PET–MR acquisition and MR-derived motion fields for correction of non-rigid motion in PET
    Charalampos Tsoumpas
    Jane E. Mackewn
    Philip Halsted
    Andrew P. King
    Christian Buerger
    John J. Totman
    Tobias Schaeffter
    Paul K. Marsden
    Annals of Nuclear Medicine, 2010, 24 : 745 - 750
  • [30] Motion correction using anatomical information in PET/CT and PET/MR hybrid imaging
    Fayad, Hadi
    Lamare, Frederic
    Merlin, Thibaut
    Visvikis, Dimitris
    QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 60 (01): : 12 - 24