Motion correction using anatomical information in PET/CT and PET/MR hybrid imaging

被引:0
|
作者
Fayad, Hadi [1 ,2 ]
Lamare, Frederic [3 ]
Merlin, Thibaut [2 ]
Visvikis, Dimitris [2 ]
机构
[1] Univ Bretagne Occidentale, Fac Med, Brest, France
[2] CHRU Morvan, INSERM, LaTIM, UMR1101, 5 Ave Foch, F-29609 Brest, France
[3] Univ Bordeaux, INCIA, UMR 5287, Talence, France
关键词
Positron-Emission Tomography; Tomography; X-Ray Computed; Magnetic Resonance Imaging; POSITRON-EMISSION-TOMOGRAPHY; OF-FLIGHT CAMERA; 4D CT DATA; RESPIRATORY MOTION; WHOLE-BODY; GENERALIZED RECONSTRUCTION; NONRIGID REGISTRATION; ONCOLOGY APPLICATIONS; PATIENT SURFACE; TUMOR MOTION;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory and cardiac motion causes qualitative and quantitative inaccuracies in whole body multi-modality imaging such as positron emission tomography coupled with computed tomography (PET/CT) and positron emission tomography/magnetic resonance imaging (PET/MRI). Solutions presented to date include motion synchronized PET and corresponding anatomical acquisitions (four dimensional [4D] PET/CT, 4D PET/MR), frequently referred to as the gating approach. This method is based on the acquisition of an external surrogate using an external device (pressure belt, optical monitoring system, spirometer etc.), subsequently used to bin PET and CT or MR anatomical data into a number of gates. A first limitation of this method is the low signal to noise ratio (SNR) of the resulting motion synchronized PET frames, given that every reconstructed frame contains only part of the count statistics available throughout a motion average PET acquisition. Another limitation is that the complex motion of internal organs cannot be fully estimated, characterized and modelled using a mono-dimensional motion signal. In order to resolve such issues, many advanced techniques have been proposed which include three consecutive major steps. These are based on firstly acquiring an external or internal motion surrogate, estimating or modelling the internal motion using anatomical information extracted from 4D anatomical images (CT and/or MR) and finally correcting for motion either in the PET raw data space, the image space or incorporate it within the PET image reconstruction which is the most optimal based motion correction method in PET/CT and in PET/MR imaging. Current research efforts are concentrating on combining the last two steps within a joint motion estimation/motion correction approach, the exploitation of MRI specific motion characterization sequences and the combination of both respiratory and cardiac motion corrections. The goal of this review is to present and discuss the different steps of all these motion correction methods in PET/CT and PET/MR imaging for whole body applications.
引用
收藏
页码:12 / 24
页数:13
相关论文
共 50 条
  • [1] Hybrid imaging with PET/CT and PET/MR
    Andreas Kjaer
    [J]. Cancer Imaging, 14 (Suppl 1)
  • [2] Rigid motion correction of PET and CT for PET/CT brain imaging
    Bickell, Matthew
    Kim, Jung-Ha
    Rezaei, Ahmadreza
    Nuyts, Johan
    Fulton, Roger
    [J]. 2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [3] PET reconstruction strategies for motion correction in coronary PET/MR imaging
    Soultanidis, Georgios
    Karakatsanis, Nicolas
    Yang, Yang
    Robson, Philip
    Fayad, Zahi
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [4] ANATOMICAL LOCALIZATION FOR PET USING MR IMAGING
    MELTZER, CC
    BRYAN, RN
    HOLCOMB, HH
    KIMBALL, AW
    MAYBERG, HS
    SADZOT, B
    LEAL, JP
    WAGNER, HN
    FROST, JJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (03) : 418 - 426
  • [5] Motion correction in dynamic PET/CT imaging
    Feeley, Christina
    Moore, Stephen
    Pande, Reena
    Park, Mi-Ae
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [6] MR-based correction of respiratory motion in oncological PET imaging using an integrated PET/MR system
    Wuerslin, Christian
    Schmidt, Holger
    Schwenzer, Nina
    Martirosian, Petros
    Claussen, Claus
    Stegger, Lars
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [7] Hybrid MR-guided and PET-guided motion correction of PET images in simultaneous PET/MR
    Feng, Tao
    Ahlman, Mark
    Tsui, Benjamin
    Guo, Liheng
    Guttman, Mike
    McVeigh, Elliot
    Bluemke, David
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [8] Clinical Value of Hybrid PET/MR Imaging Brain Imaging Using PET/MR Imaging
    Kas, Aurelie
    Rozenblum, Laura
    Pyatigorskaya, Nadya
    [J]. MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2023, 31 (04) : 591 - 604
  • [9] Motion Correction for Simultaneous PET/MR Brain Imaging Using a RF-Penetrable PET Insert
    Fisher, Jonathan
    Groll, Andrew
    Levin, Craig S.
    [J]. 2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [10] Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging
    Lee, Tzu C.
    Alessio, Adam M.
    Miyaoka, Robert M.
    Kinahan, Paul E.
    [J]. QUARTERLY JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 60 (01): : 25 - 39