Motion correction using anatomical information in PET/CT and PET/MR hybrid imaging

被引:0
|
作者
Fayad, Hadi [1 ,2 ]
Lamare, Frederic [3 ]
Merlin, Thibaut [2 ]
Visvikis, Dimitris [2 ]
机构
[1] Univ Bretagne Occidentale, Fac Med, Brest, France
[2] CHRU Morvan, INSERM, LaTIM, UMR1101, 5 Ave Foch, F-29609 Brest, France
[3] Univ Bordeaux, INCIA, UMR 5287, Talence, France
关键词
Positron-Emission Tomography; Tomography; X-Ray Computed; Magnetic Resonance Imaging; POSITRON-EMISSION-TOMOGRAPHY; OF-FLIGHT CAMERA; 4D CT DATA; RESPIRATORY MOTION; WHOLE-BODY; GENERALIZED RECONSTRUCTION; NONRIGID REGISTRATION; ONCOLOGY APPLICATIONS; PATIENT SURFACE; TUMOR MOTION;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory and cardiac motion causes qualitative and quantitative inaccuracies in whole body multi-modality imaging such as positron emission tomography coupled with computed tomography (PET/CT) and positron emission tomography/magnetic resonance imaging (PET/MRI). Solutions presented to date include motion synchronized PET and corresponding anatomical acquisitions (four dimensional [4D] PET/CT, 4D PET/MR), frequently referred to as the gating approach. This method is based on the acquisition of an external surrogate using an external device (pressure belt, optical monitoring system, spirometer etc.), subsequently used to bin PET and CT or MR anatomical data into a number of gates. A first limitation of this method is the low signal to noise ratio (SNR) of the resulting motion synchronized PET frames, given that every reconstructed frame contains only part of the count statistics available throughout a motion average PET acquisition. Another limitation is that the complex motion of internal organs cannot be fully estimated, characterized and modelled using a mono-dimensional motion signal. In order to resolve such issues, many advanced techniques have been proposed which include three consecutive major steps. These are based on firstly acquiring an external or internal motion surrogate, estimating or modelling the internal motion using anatomical information extracted from 4D anatomical images (CT and/or MR) and finally correcting for motion either in the PET raw data space, the image space or incorporate it within the PET image reconstruction which is the most optimal based motion correction method in PET/CT and in PET/MR imaging. Current research efforts are concentrating on combining the last two steps within a joint motion estimation/motion correction approach, the exploitation of MRI specific motion characterization sequences and the combination of both respiratory and cardiac motion corrections. The goal of this review is to present and discuss the different steps of all these motion correction methods in PET/CT and PET/MR imaging for whole body applications.
引用
下载
收藏
页码:12 / 24
页数:13
相关论文
共 50 条
  • [41] Use of Thermal Imaging for Respiratory Motion Correction in PET/CT
    Fang, Michael
    Acuffi, Shelley
    Osborne, Dustin
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [42] Optimal motion correction in PET/MR imaging using an MR based patient specific model.
    Fayad, Hadi
    Thomas, Kuestner
    Schmidt, Holger
    Visvikis, Dimitris
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [43] MR Imaging-Guided Attenuation Correction of PET Data in PET/MR Imaging
    Izquierdo-Garcia, David
    Catana, Ciprian
    PET CLINICS, 2016, 11 (02) : 129 - +
  • [44] Evaluation of Musculoskeletal Disorders with PET, PET/CT, and PET/MR Imaging
    Chen, Karen
    Blebea, Judy
    Laredo, Jean-Denis
    Chen, Wengen
    Alavi, Abass
    Torigian, Drew A.
    PET CLINICS, 2008, 3 (03) : 451 - +
  • [45] PET, PET/ CT, and PET/ MR Imaging Assessment of Breast Cancer
    Shamim, Shamim Ahmed
    Torigian, Drew A.
    Kumar, Rakesh
    PET CLINICS, 2008, 3 (03) : 381 - +
  • [46] Impact of motion and partial volume effects correction on PET myocardial perfusion imaging using simultaneous PET-MR
    Petibon, Yoann
    Guehl, Nicolas J.
    Reese, Timothy G.
    Ebrahimi, Behzad
    Normandin, Marc D.
    Shoup, Timothy M.
    Alpert, Nathaniel M.
    El Fakhri, Georges
    Ouyang, Jinsong
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (02): : 326 - 343
  • [47] Using ITK to obtain motion transform in anatomically guided PET motion correction for simultaneous PET/MR
    Cheng, Ju-Chieh
    Laforest, Richard
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [48] Respiratory and cardiac motion correction in dual gated PET/MR imaging
    Hadi Fayad
    Florian Monnier
    Freedy Odille
    Jacques Felblinger
    Frederic Lamare
    Dimitris Visvikis
    EJNMMI Physics, 2 (Suppl 1)
  • [49] MR-based respiratory and cardiac motion correction for PET imaging
    Kuestner, Thomas
    Schwartz, Martin
    Martirosian, Petros
    Gatidis, Sergios
    Seith, Ferdinand
    Gilliam, Christopher
    Blu, Thierry
    Fayad, Hadi
    Visvikis, Dimitris
    Schick, F.
    Yang, B.
    Schmidt, H.
    Schwenzer, N. F.
    MEDICAL IMAGE ANALYSIS, 2017, 42 : 129 - 144
  • [50] Attenuation Correction of PET/MR Imaging
    Chen, Yasheng
    An, Hongyu