Probe Diagnostics of Plasma Parameters in a Large-Volume Glow Discharge With Coaxial Gridded Hollow Electrodes

被引:15
|
作者
Yuan, Chengxun [1 ]
Kudryavtsev, A. A. [1 ,2 ]
Saifutdinov, A. I. [1 ,2 ]
Sysoev, S. S. [1 ]
Tian, Ruihuan [1 ]
Yao, Jingfeng [1 ]
Zhou, Zhongxiang [1 ]
机构
[1] Harbin Inst Technol, Dept Phys, Harbin 150001, Heilongjiang, Peoples R China
[2] St Petersburg State Univ, Dept Opt, St Petersburg 199034, Russia
基金
俄罗斯科学基金会; 中国国家自然科学基金;
关键词
Glow discharges; plasma applications; plasma measurements; plasma properties; TRANSMISSION; MICROWAVES;
D O I
10.1109/TPS.2017.2758170
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Results of the experimental investigation of glow discharge plasma created in a large-volume discharge chamber are presented. The discharge configuration consists of two coaxial gridded electrodes placed in a metallic vacuum chamber. The inner electrode and the chamber housing were grounded while time-varying power up to 2 kV with frequency 20 kHz was applied on the outer electrode. The discharge was created in air at a pressure of 50 Pa and in argon at pressures of 50 and 100 Pa. Measurements of plasma parameters were carried out with a single-probe technique using the commercial Impedans Langmuir Probe system. In order to perform time-resolved measurements, an additional synchronizing device was developed. Variation in time of such plasma parameters as electron temperature, charged particle densities, and electron energy distribution function was obtained during the experiments. It is shown that both electron temperature and density change slightly in time. Obtained results indicate that the plasma created in the considered chamber configuration is similar to the negative glow region of a direct-current glow discharge.
引用
收藏
页码:3110 / 3113
页数:4
相关论文
共 50 条
  • [31] DESIGN AND EVALUATION OF A COMPUTER-CONTROLLED LANGMUIR PROBE SYSTEM FOR GLOW-DISCHARGE PLASMA DIAGNOSTICS
    FANG, DC
    WILLIAMS, RR
    MARCUS, RK
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1990, 5 (06) : 569 - 573
  • [32] Double flush-mounted probe diagnostics and data analysis technique for argon glow discharge plasma
    Yu, Pengcheng
    Liu, Yu
    Cao, Jinxiang
    Xu, Liang
    Zhang, Xiao
    Zhang, Zhongkai
    Wang, Pi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (01):
  • [33] PROBE AND SPECTRAL MEASUREMENTS OF THE PLASMA PARAMETERS OF AN ARC-DISCHARGE WITH A HOLLOW-CATHODE
    GRDLICHKO, DP
    SAKHAROV, VB
    HIGH TEMPERATURE, 1978, 16 (04) : 597 - 601
  • [34] Formation of Large-Volume High-Pressure Plasma in Triode-Configuration Discharge Devices
    江超
    王又青
    Plasma Science and Technology, 2006, (02) : 185 - 189
  • [35] Formation of large-volume high-pressure plasma in triode-configuration discharge devices
    Jiang, Chao
    Wang, Youqing
    PLASMA SCIENCE & TECHNOLOGY, 2006, 8 (02) : 185 - 189
  • [36] Formation of Large-Volume High-Pressure Plasma in Triode-Configuration Discharge Devices
    江超
    王又青
    Plasma Science and Technology, 2006, 8 (02) : 185 - 189
  • [37] A STUDY ON PLASMA PARAMETERS OF He AND Ne-He NANOSECOND PULSED LONGITUDINAL DISCHARGE FOR HIGH-TEMPERATURE LARGE-VOLUME TUBE
    Slaveeva, Stefka
    Temelkov, Krassimir
    Vuchkov, Nikolay
    COMPTES RENDUS DE L ACADEMIE BULGARE DES SCIENCES, 2012, 65 (08): : 1043 - 1048
  • [38] Periodic long-range transport in a large volume dc glow discharge dusty plasma
    Thomas, E
    Amatucci, WE
    Compton, C
    Christy, B
    Jackson, JD
    PHYSICS OF PLASMAS, 2003, 10 (04) : 1159 - 1163
  • [39] Fast Double Probe Technique And Effect of Non-Uniform Glow Discharge System on Plasma Parameters
    Akbar, D.
    Bilikmen, S.
    CAPPSA 2005, PROCEEDINGS, 2005, : 181 - 190
  • [40] Plasma parameters of an oxygen microwave discharge obtained by probe diagnostics: I. Axial distributions
    Kiss'ovski, Z
    Tsankov, T
    Korzec, D
    Kytzia, S
    Engemann, J
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2006, 15 (01): : 126 - 134