Monte Carlo studies of a novel X-ray tube anode design

被引:0
|
作者
Tavora, LMN
Gilboy, WB [1 ]
Morton, EJ
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 5XH, Surrey, England
[2] Univ Coimbra, Dept Fis, P-3004516 Coimbra, Portugal
关键词
X-ray tube; anode design; Monte Carlo simulation;
D O I
10.1016/S0969-806X(01)00322-X
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
When energetic electrons are incident on high atomic number absorbers, a substantial fraction is back-scattered. This phenomenon is responsible for several undesirable effects in X-ray tubes, in particular a reduction in the X-ray output. The extent of this shortfall has been estimated by using Monte Carlo simulation to start electrons at increasing depth inside the anode, the results indicating that an output enhancement of nearly 50% could be achieved in principle if the electrons wasted in back-scatter events could be trapped inside a tungsten anode. To test this idea a further set of simulations were done for a novel anode geometry. Results showed that X-ray tube efficiencies might be substantially enhanced by this approach. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:527 / 529
页数:3
相关论文
共 50 条
  • [1] Monte Carlo simulation of x-ray tube spectra with PENELOPE
    Jia, Pengxiang
    Xie, Yaoqin
    Bao, Shanglian
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 503 - 506
  • [2] Monte Carlo simulation of a computed tomography x-ray tube
    Bazalova, Magdalena
    Verhaegen, Frank
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (19): : 5945 - 5955
  • [3] Monte Carlo design of X-ray flattening filters
    Li, Quanfeng
    Yan, Huiyong
    [J]. Qinghua Daxue Xuebao/Journal of Tsinghua University, 2003, 43 (06): : 732 - 734
  • [4] Monte-Carlo simulation of a micro focal X-ray tube
    Tavora, LMN
    Morton, EJ
    [J]. 1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 783 - 787
  • [5] Design of An MR Compatible Rotating Anode X-Ray Tube
    Lillaney, P.
    Shin, M.
    Hinshaw, W.
    Fahrig, R.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3949 - 3949
  • [6] X-RAY COLLIMATOR DESIGN USING MONTE CARLO SIMULATIONS
    Han, Eun Young
    Clarkson, Richard
    Sharma, Sunil
    Corry, Peter M.
    Moros, Eduardo G.
    Ratanatharathorn, Vaneerat
    [J]. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2013, 25 (06):
  • [7] Monte Carlo simulation of the effects of anode surface roughness on x-ray spectra
    Kakonyi, Robert
    Erdelyi, Miklos
    Szabo, Gabor
    [J]. MEDICAL PHYSICS, 2010, 37 (11) : 5737 - 5745
  • [8] X-ray scattering in X-ray fluorescence spectra with X-ray tube excitation - Modelling, experiment, and Monte-Carlo simulation
    Hodoroaba, V. -D.
    Radtke, M.
    Vincze, L.
    Rackwitz, V.
    Reuter, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (24): : 3568 - 3575
  • [9] A Monte Carlo study of x-ray fluorescence in x-ray detectors
    Boone, JM
    Seibert, JA
    Sabol, JM
    Tecotzky, M
    [J]. MEDICAL PHYSICS, 1999, 26 (06) : 905 - 916
  • [10] X-RAY DOSE ESTIMATION FROM CATHODE RAY TUBE MONITORS BY MONTE CARLO CALCULATION
    Khaledi, Navid
    Arbabi, Azim
    Dabaghi, Moloud
    [J]. HEALTH PHYSICS, 2015, 108 (04): : 401 - 406