Monte Carlo studies of a novel X-ray tube anode design

被引:0
|
作者
Tavora, LMN
Gilboy, WB [1 ]
Morton, EJ
机构
[1] Univ Surrey, Dept Phys, Guildford GU2 5XH, Surrey, England
[2] Univ Coimbra, Dept Fis, P-3004516 Coimbra, Portugal
关键词
X-ray tube; anode design; Monte Carlo simulation;
D O I
10.1016/S0969-806X(01)00322-X
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
When energetic electrons are incident on high atomic number absorbers, a substantial fraction is back-scattered. This phenomenon is responsible for several undesirable effects in X-ray tubes, in particular a reduction in the X-ray output. The extent of this shortfall has been estimated by using Monte Carlo simulation to start electrons at increasing depth inside the anode, the results indicating that an output enhancement of nearly 50% could be achieved in principle if the electrons wasted in back-scatter events could be trapped inside a tungsten anode. To test this idea a further set of simulations were done for a novel anode geometry. Results showed that X-ray tube efficiencies might be substantially enhanced by this approach. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:527 / 529
页数:3
相关论文
共 50 条
  • [31] Comparison of Monte Carlo tally techniques for dosimetry in a transmission-type x-ray tube
    Feng, Chen-Ju
    Lin, Chin-Hsiung
    Wu, Shu-Wei
    Luo, Shih-Yong
    Yang, Ya-Ru
    Lee, Chao-Hua
    Tseng, Shao-Chun
    Lee, Shen-Hao
    Hsu, Shih-Ming
    Wu, Chin-Hui
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (06):
  • [32] Monte Carlo kilovoltage X-ray tube simulation: A statistical analysis and compact simulation method
    Bootsma, G. J.
    Nordstrom, H.
    Eriksson, M.
    Jaffray, D. A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 72 : 80 - 87
  • [33] Monte Carlo X-Ray Tube Simulation for CBCT: Primary Source Phase Space Compression
    Bootsma, G.
    Nordstrom, H.
    Eriksson, M.
    Jaffray, D.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E153 - E153
  • [34] AN X-RAY TUBE WITH A ROTATING ANODE AND AN EARTHED CATHODE
    SAWADA, S
    TAKOO, I
    FUJII, SI
    [J]. JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1957, 12 (02) : 147 - 150
  • [35] ON A NEW TYPE OF ROTATING ANODE X-RAY TUBE
    TAYLOR, A
    [J]. PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1948, 61 (343): : 86 - &
  • [36] Compact Anode Design with the Heat Capacity Performance in Rotating Anode X-ray Tube for Digital Radiography
    Lee, Seok Moon
    [J]. APPLIED SCIENCE AND CONVERGENCE TECHNOLOGY, 2015, 24 (05): : 136 - 141
  • [37] X-ray tube with needle-like anode
    Slapa, M
    Stras, W
    Traczyk, M
    Dora, J
    Snopek, M
    Gutowski, R
    Drabik, W
    [J]. NUKLEONIKA, 2002, 47 (03) : 101 - 105
  • [38] Heat transmission through the anode of an x-ray tube
    Nieukerke, KHP
    [J]. PHYSICA, 1939, 6 : 721 - 727
  • [39] MONTE-CARLO CALCULATIONS OF X-RAY BACKSCATTERING
    BERGER, MJ
    RASO, D
    [J]. RADIATION RESEARCH, 1958, 9 (01) : 91 - 91
  • [40] Mammography X-ray spectra simulated with Monte Carlo
    Vega-Carrillo, H. R.
    Gonzalez, J. Ramirez
    Manzanares-Acuna, E.
    Hernandez-Davila, V. M.
    Villasana, R. Hernandez
    Mercado, G. A.
    [J]. MEDICAL PHYSICS, 2008, 1032 : 208 - 211