Monte Carlo simulation of the effects of anode surface roughness on x-ray spectra

被引:10
|
作者
Kakonyi, Robert [1 ]
Erdelyi, Miklos [2 ]
Szabo, Gabor [2 ]
机构
[1] Univ Szeged, Reg Cooperat Res Ctr Life & Mat Sci, H-6720 Szeged, Hungary
[2] Univ Szeged, Dept Opt & Quantum Elect, H-6720 Szeged, Hungary
关键词
bremsstrahlung; x-ray; Monte Carlo; anode surface roughness; heel effect; beam hardening; DIAGNOSTIC-RADIOLOGY; TUBE; FILTRATION; MAMMOGRAPHY; TARGETS;
D O I
10.1118/1.3495541
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Spectral and angular distribution of the x-ray beam generated by medical x-ray tubes as a function of anode surface roughness was analyzed. Methods: Different sets of profiles such as ideal flat, regular profiles, and measured profiles adopted from the literature were analyzed by means of MCNPX Monte Carlo simulator. The geometry used was simplified to separate different physical effects. A sphere centered on the origin of the coordinate system was divided into two hemispheres filled with tungsten and a vacuum, respectively. The studied anode surfaces were placed at the center of the plane of the hemisphere. The profiles were realized by means of the general lattice structure of the MCNPX. The energy and angular distributions of the excited photons were recorded with energy and angular resolutions of 0.5 keV and 1 degrees, respectively, by means of point detectors. The range of the studied anode surface roughness was 0-550 mu m R(a). The emission angle dependencies of the following quantities were analyzed: Half value layer (HVL) value, intensity, and spectral photon flux. Results: The analysis of the HVL of the x-ray beam showed that around an emission angle of 5 degrees, the hardness of the beam was practically independent of the surface roughness. The value of this emission angle depends on the filtration. Below this critical angle, the HVL value decreases, while at a higher emission angle, the beam becomes harder with increasing surface roughness. The intensity degradation saturates with increasing roughness. The position of the maximum spectral photon flux shifts to higher emission angles as the anode surface roughness increases. The surface roughness (R(a)) was found to be an inadequate quantity to describe the effect of anode surface roughness on x-ray spectra since no definite connection was found between the values of the intensity degradation and surface roughness. At 120 kVp tube voltage and at a 3.84 mu m R(a) roughness value, the effect of anode surface roughness introduces a 5% and 12% intensity degradation at a 5 degrees and 12 degrees emission angle, respectively. However, it has a higher impact at low tube voltages (<60 keV), e.g., in mammography systems where the intensity degradation could even be 25% at the "newly" polished anode surface. Conclusions: The effects of anode surface roughness on x-ray spectra were successfully simulated by a Monte Carlo method. It was proved that the effect of the anode surface roughness could not be modeled by simple filters made from the anode material. The surface roughness (R(a)) was found to be an inadequate quantity to describe the effect of anode surface roughness on x-ray spectra. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3495541]
引用
收藏
页码:5737 / 5745
页数:9
相关论文
共 50 条
  • [1] Quantifying the effect of anode surface roughness on diagnostic x-ray spectra using Monte Carlo simulation
    Mehranian, A.
    Ay, M. R.
    Alam, N. Riyahi
    Zaidi, H.
    [J]. MEDICAL PHYSICS, 2010, 37 (02) : 742 - 752
  • [2] Quantitative assessment of the Effect of Anode Surface Roughness on Diagnostic X-ray Spectra: A Monte Carlo Simulation Study
    Mehranian, A.
    Ay, M. R.
    Alam, N. Riyahi
    Zaidi, H.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2902 - +
  • [3] Simulation of the effect of anode surface roughness on diagnostic x-ray spectra
    Nowotny, R
    Meghzifene, K
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (22): : 3973 - 3983
  • [4] Monte Carlo simulation of x-ray spectra in mammography
    Ng, KP
    Kwok, CS
    Tang, FH
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (05): : 1309 - 1318
  • [5] Monte Carlo simulation of X-ray spectra produced by Linac
    Permatasari, Intan Dyah Ayu
    Suharyana
    Riyatun
    [J]. 9TH INTERNATIONAL CONFERENCE ON PHYSICS AND ITS APPLICATIONS (ICOPIA), 2019, 1153
  • [6] Monte Carlo simulation of x-ray tube spectra with PENELOPE
    Jia, Pengxiang
    Xie, Yaoqin
    Bao, Shanglian
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 2 - DIAGNOSTIC IMAGING, 2009, 25 : 503 - 506
  • [7] Monte Carlo simulation for x-ray detector
    Cai, Houzhi
    Liu, Jinyuan
    Peng, Xiang
    Niu, Lihong
    Peng, Wenda
    Long, Jinghua
    [J]. INTERNATIONAL SYMPOSIUM ON PHOTOELECTRONIC DETECTION AND IMAGING 2011: ADVANCES IN IMAGING DETECTORS AND APPLICATIONS, 2011, 8194
  • [8] A Monte Carlo simulation of x-ray mammography
    Spyrou, G
    Panayiotakis, G
    Tzanakos, G
    [J]. PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 842 - 843
  • [9] Mammography X-ray spectra simulated with Monte Carlo
    Vega-Carrillo, H. R.
    Gonzalez, J. Ramirez
    Manzanares-Acuna, E.
    Hernandez-Davila, V. M.
    Villasana, R. Hernandez
    Mercado, G. A.
    [J]. MEDICAL PHYSICS, 2008, 1032 : 208 - 211
  • [10] X-ray scattering in X-ray fluorescence spectra with X-ray tube excitation - Modelling, experiment, and Monte-Carlo simulation
    Hodoroaba, V. -D.
    Radtke, M.
    Vincze, L.
    Rackwitz, V.
    Reuter, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2010, 268 (24): : 3568 - 3575