Comparison of corneal dynamic parameters and tomographic measurements using Scheimpflug imaging in keratoconus

被引:57
|
作者
Chan, Tommy C. Y. [1 ]
Wang, Yu Meng [1 ]
Yu, Marco [2 ]
Jhanji, Vishal [1 ,3 ]
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Hang Seng Management Coll, Dept Math & Stat, Hong Kong, Hong Kong, Peoples R China
[3] Univ Pittsburgh, UPMC Eye Ctr, Pittsburgh, PA USA
关键词
FORME-FRUSTE KERATOCONUS; SUBCLINICAL KERATOCONUS; FELLOW EYES; INTRAOCULAR-PRESSURE; PACHYMETRY; ELEVATION; PENTACAM; HEALTHY; BIOMECHANICS; ORIENTATION;
D O I
10.1136/bjophthalmol-2017-310355
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To compare the diagnostic ability of corneal tomography and corneal dynamic response measurements in normal and keratoconus eyes. Methods Consecutive patients with grade II-III keratoconus and age-matched normal subjects were recruited. Corneal imaging was performed using Pentacam (Oculus Optikgerate, Wetzlar, Germany) and Corvis (Oculus Optikgerate). A beta version of Corvis software was used with three additional parameters: maximal change of arc length, deformation amplitude (DA) ratio 1 and DA ratio 2. Diagnostic ability of both devices to differentiate normal and keratoconus eyes was evaluated using receiver-operating characteristic (ROC) curves. The areas under the ROC curve (AUC) and partial AUC (pAUC) for specificity >= 80% for each parameter of Corvis and final D value of Belin/Ambrosio Enhanced Ectasia Display (BAD) were compared. Results Forty-two eyes of 42 patients (21 patients with keratoconus and 21 normal subjects) were included. Both groups were age matched (p=0.760). The ROC analysis showed that the final D value of BAD had the highest AUC (0.994) and pAUC (0.194). Maximum inverse radius had the highest AUC (0.954) but a relatively lower pAUC (0.158), while DA ratio 2 had the second highest AUC (0.946) together with the highest pAUC (0.177) among Corvis parameters. There was no significant difference between AUC and pAUC of BAD compared with those of DA ratio 1 (p=0.162) and DA ratio 2 (p=0.208). Conclusions The results of our study suggest that Corvis measurements have the potential to differentiate keratoconus and normal eyes. The diagnostic ability of novel parameters on Corvis was comparable to Pentacam.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 50 条
  • [31] Comparison of ectasia detection in early keratoconus using Scheimpflug-based corneal tomography and biomechanical assessments
    Wallace, Henry B.
    Vellara, Hans
    Gokul, Akilesh
    Meyer, Jay
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2022, 49 (08): : 885 - 886
  • [32] Comparison of Ectasia Detection in Early Keratoconus Using Scheimpflug-Based Corneal Tomography and Biomechanical Assessments
    Wallace, Henry B.
    Vellara, Hans R.
    Gokul, Akilesh
    Mcghee, Charles N. J.
    Meyer, Jay J.
    CORNEA, 2023, 42 (12) : 1528 - 1535
  • [33] Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device
    Bograd, Alexandra
    Himmel, Isabelle
    Pfister, Isabel B.
    Seiler, Theo G.
    Frueh, Beatrice E.
    Tappeiner, Christoph
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2023, 262 (3) : 891 - 901
  • [34] Correction to: Comparison of corneal measurements in keratoconus eyes with two swept‑source‑optical coherence tomography devices and a Scheimpflug device
    Alexandra Bograd
    Isabelle Himmel
    Isabel B. Pfister
    Theo G. Seiler
    Beatrice E. Frueh
    Christoph Tappeiner
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 1009 - 1009
  • [35] Comparison of corneal measurements in keratoconus eyes with two swept-source-optical coherence tomography devices and a Scheimpflug device
    Alexandra Bograd
    Isabelle Himmel
    Isabel B. Pfister
    Theo G. Seiler
    Beatrice E. Frueh
    Christoph Tappeiner
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2024, 262 : 891 - 901
  • [36] Comparison of Corneal Topography in Keratoconus Using Placido-Based, Scheimpflug-Based, and OCT-Based Corneal Topographers
    Toda, R., II
    Higashiura, R.
    Fuchihata, M.
    Kou, S.
    Inoue, T.
    Maeda, N.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [37] Reliability analysis of successive Corneal Visualization Scheimpflug Technology measurements in different keratoconus stages
    Flockerzi, Elias
    Haefner, Larissa
    Xanthopoulou, Kassandra
    Daas, Loay
    Munteanu, Cristian
    Langenbucher, Achim
    Seitz, Berthold
    ACTA OPHTHALMOLOGICA, 2022, 100 (01) : E83 - E90
  • [38] Dynamic Scheimpflug-based Assessment of Keratoconus and the Effects of Corneal Cross-linking
    Bak-Nielsen, Sashia
    Pedersen, Iben B.
    Ivarsen, Anders
    Hjortdal, Jesper
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (06) : 408 - 414
  • [39] Evaluation of Corneal Parameters with Scheimpflug Imaging in Patients with Rheumatoid Arthritis
    Cingu, Abdullah Kursat
    Cinar, Yasin
    Turkcu, Fatih Mehmet
    Sahin, Muhammed
    Kaya, Savas
    Bozkurt, Mehtap
    Sahin, Alparslan
    Yuksel, Harun
    Ari, Seyhmus
    Caca, Ihsan
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2013, 21 (05) : 360 - 365
  • [40] Natural history of corneal haze after corneal collagen crosslinking in keratoconus using Scheimpflug analysis
    Kim, Bia Z.
    Jordan, Charlotte A.
    McGhee, Charles N. J.
    Patel, Dipika V.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (07): : 1053 - 1059