Comparison of corneal dynamic parameters and tomographic measurements using Scheimpflug imaging in keratoconus

被引:57
|
作者
Chan, Tommy C. Y. [1 ]
Wang, Yu Meng [1 ]
Yu, Marco [2 ]
Jhanji, Vishal [1 ,3 ]
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Hang Seng Management Coll, Dept Math & Stat, Hong Kong, Hong Kong, Peoples R China
[3] Univ Pittsburgh, UPMC Eye Ctr, Pittsburgh, PA USA
关键词
FORME-FRUSTE KERATOCONUS; SUBCLINICAL KERATOCONUS; FELLOW EYES; INTRAOCULAR-PRESSURE; PACHYMETRY; ELEVATION; PENTACAM; HEALTHY; BIOMECHANICS; ORIENTATION;
D O I
10.1136/bjophthalmol-2017-310355
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To compare the diagnostic ability of corneal tomography and corneal dynamic response measurements in normal and keratoconus eyes. Methods Consecutive patients with grade II-III keratoconus and age-matched normal subjects were recruited. Corneal imaging was performed using Pentacam (Oculus Optikgerate, Wetzlar, Germany) and Corvis (Oculus Optikgerate). A beta version of Corvis software was used with three additional parameters: maximal change of arc length, deformation amplitude (DA) ratio 1 and DA ratio 2. Diagnostic ability of both devices to differentiate normal and keratoconus eyes was evaluated using receiver-operating characteristic (ROC) curves. The areas under the ROC curve (AUC) and partial AUC (pAUC) for specificity >= 80% for each parameter of Corvis and final D value of Belin/Ambrosio Enhanced Ectasia Display (BAD) were compared. Results Forty-two eyes of 42 patients (21 patients with keratoconus and 21 normal subjects) were included. Both groups were age matched (p=0.760). The ROC analysis showed that the final D value of BAD had the highest AUC (0.994) and pAUC (0.194). Maximum inverse radius had the highest AUC (0.954) but a relatively lower pAUC (0.158), while DA ratio 2 had the second highest AUC (0.946) together with the highest pAUC (0.177) among Corvis parameters. There was no significant difference between AUC and pAUC of BAD compared with those of DA ratio 1 (p=0.162) and DA ratio 2 (p=0.208). Conclusions The results of our study suggest that Corvis measurements have the potential to differentiate keratoconus and normal eyes. The diagnostic ability of novel parameters on Corvis was comparable to Pentacam.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 50 条
  • [21] Assessment of Corneal Parameters in Patients with Constitutional Thinness Using Scheimpflug Imaging
    Gunes, Alime
    Bas, Funda Yildirim
    Arslan, Bahriye
    Tok, Levent
    Tok, Ozlem
    Salman, Zeliha
    SEMINARS IN OPHTHALMOLOGY, 2018, 33 (02) : 175 - 178
  • [22] Comparison of a Scheimpflug imaging with other screening indices in diagnosing keratoconus and keratoconus suspect
    Huo, Yan
    Xie, Ruisi
    Chen, Xuan
    Li, Shuangcheng
    Zou, Haohan
    Liu, Yutong
    Wang, Yan
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [23] Comparative evaluation of dual Scheimpflug imaging parameters in keratoconus, early keratoconus, and normal eyes
    Reddy, Jagadesh C.
    Rapuarto, Christopher J.
    Cater, Jacqueline R.
    Suri, Kunal
    Nagra, Parveen K.
    Hammersmith, Kristin M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (04): : 582 - 592
  • [24] Repeatability of Scheimpflug based corneal tomography parameters in advanced keratoconus with thin corneas
    Wadhwa, Himanshu
    Gokul, Akilesh
    Li, Ye
    Cheung, Isabella
    Angelo, Lize
    McGhee, Charles N. J.
    Ziaei, Mohammed
    EYE, 2023, 37 (16) : 3429 - 3434
  • [25] Repeatability of Scheimpflug based corneal tomography parameters in advanced keratoconus with thin corneas
    Himanshu Wadhwa
    Akilesh Gokul
    Ye Li
    Isabella Cheung
    Lize Angelo
    Charles N. J. McGhee
    Mohammed Ziaei
    Eye, 2023, 37 : 3429 - 3434
  • [26] Study of corneal backscatter by Scheimpflug imaging in patients with keratoconus treated with corneal Cross-linking
    Moscarda, Eva Josefina Nunez
    Boned-Murillo, Ana
    Diaz-Barreda, Ma Dolores
    El Bakkali, Ismael Bakkali
    Rivases, Guillermo Perez
    Cisneros, Pablo
    deRivas, Marta Orejudo
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [27] Assessment of Keratoconus Risk in Very Asymmetric Ectasia Using Corneal Tomographic and Biomechanical Parameters
    Zhang, Xiaoyu
    Ding, Lan
    Sun, Ling
    Sun, Bingqing
    Huang, Yangyi
    Qian, Yishan
    Zhou, Xingtao
    CLINICAL OPHTHALMOLOGY, 2023, 17 : 3569 - 3577
  • [28] Evaluation of Intereye Corneal Asymmetry in Patients with Keratoconus. A Scheimpflug Imaging Study
    Dienes, Lorant
    Kranitz, Kinga
    Juhasz, Eva
    Gyenes, Andrea
    Takacs, Agnes
    Mihaltz, Kata
    Nagy, Zoltan Z.
    Kovacs, Illes
    PLOS ONE, 2014, 9 (10):
  • [29] Evaluation of corneal elevation in eyes with subclinical keratoconus and keratoconus using Galilei double Scheimpflug analyzer
    Jafarinasab, Mohammad Reza
    Feizi, Sepehr
    Karimian, Farid
    Hasanpour, Hossein
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (03) : 377 - 384
  • [30] Scheimpflug Imaging Parameters Associated with Tear Mediators and Bronchial Asthma in Keratoconus
    Pasztor, Dorottya
    Kolozsvari, Bence Lajos
    Csutak, Adrienne
    Berta, Andras
    Hassan, Ziad
    Kettesy, Beata Andrea
    Gogolak, Peter
    Fodor, Mariann
    JOURNAL OF OPHTHALMOLOGY, 2016, 2016