Comparison of corneal dynamic parameters and tomographic measurements using Scheimpflug imaging in keratoconus

被引:57
|
作者
Chan, Tommy C. Y. [1 ]
Wang, Yu Meng [1 ]
Yu, Marco [2 ]
Jhanji, Vishal [1 ,3 ]
机构
[1] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Hong Kong, Peoples R China
[2] Hang Seng Management Coll, Dept Math & Stat, Hong Kong, Hong Kong, Peoples R China
[3] Univ Pittsburgh, UPMC Eye Ctr, Pittsburgh, PA USA
关键词
FORME-FRUSTE KERATOCONUS; SUBCLINICAL KERATOCONUS; FELLOW EYES; INTRAOCULAR-PRESSURE; PACHYMETRY; ELEVATION; PENTACAM; HEALTHY; BIOMECHANICS; ORIENTATION;
D O I
10.1136/bjophthalmol-2017-310355
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim To compare the diagnostic ability of corneal tomography and corneal dynamic response measurements in normal and keratoconus eyes. Methods Consecutive patients with grade II-III keratoconus and age-matched normal subjects were recruited. Corneal imaging was performed using Pentacam (Oculus Optikgerate, Wetzlar, Germany) and Corvis (Oculus Optikgerate). A beta version of Corvis software was used with three additional parameters: maximal change of arc length, deformation amplitude (DA) ratio 1 and DA ratio 2. Diagnostic ability of both devices to differentiate normal and keratoconus eyes was evaluated using receiver-operating characteristic (ROC) curves. The areas under the ROC curve (AUC) and partial AUC (pAUC) for specificity >= 80% for each parameter of Corvis and final D value of Belin/Ambrosio Enhanced Ectasia Display (BAD) were compared. Results Forty-two eyes of 42 patients (21 patients with keratoconus and 21 normal subjects) were included. Both groups were age matched (p=0.760). The ROC analysis showed that the final D value of BAD had the highest AUC (0.994) and pAUC (0.194). Maximum inverse radius had the highest AUC (0.954) but a relatively lower pAUC (0.158), while DA ratio 2 had the second highest AUC (0.946) together with the highest pAUC (0.177) among Corvis parameters. There was no significant difference between AUC and pAUC of BAD compared with those of DA ratio 1 (p=0.162) and DA ratio 2 (p=0.208). Conclusions The results of our study suggest that Corvis measurements have the potential to differentiate keratoconus and normal eyes. The diagnostic ability of novel parameters on Corvis was comparable to Pentacam.
引用
收藏
页码:42 / 47
页数:6
相关论文
共 50 条
  • [1] Evaluation of corneal biomechanics in keratoconus using dynamic ultra-high-speed Scheimpflug measurements
    Brettl, S.
    Zeitz, P. Franko
    Fuchsluger, T. A.
    OPHTHALMOLOGE, 2018, 115 (08): : 644 - 648
  • [2] Comparison of Scheimpflug Imaging Analysis of Pellucid Marginal Corneal Degeneration and Keratoconus
    Kocluk, Yusuf
    Yalniz-Akkaya, Zuleyha
    Burcu, Ayse
    Ornek, Firdevs
    OPHTHALMIC RESEARCH, 2015, 53 (01) : 21 - 27
  • [3] Classification of dynamic corneal response parameters concerning the topographical severity of keratoconus using the dynamic Scheimpflug imaging and machine-learning algorithms
    Herber, Robert
    Spoerl, Eberhard
    Pillunat, Lutz E.
    Raiskup, Frederik
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [4] Comparison of corneal measurements in keratoconus using swept-source optical coherence tomography and combined Placido-Scheimpflug imaging
    Chan, Tommy C. Y.
    Biswas, Sayantan
    Yu, Marco
    Jhanji, Vishal
    ACTA OPHTHALMOLOGICA, 2017, 95 (06) : E486 - E494
  • [5] Repeatability and reproducibility of corneal deformation response parameters of dynamic ultra-high-speed Scheimpflug imaging in keratoconus
    Herber, Robert
    Vinciguerra, Riccardo
    Lopes, Bernardo
    Raiskup, Frederik
    Pillunat, Lutz E.
    Vinciguerra, Paolo
    Ambrosio, Renato, Jr.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01): : 86 - 94
  • [6] Scheimpflug parameters after corneal collagen crosslinking for keratoconus
    Toprak, Ibrahim
    Yildirim, Cem
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (06) : 793 - 798
  • [7] Evaluation of corneal flattening in progressive keratoconus with Scheimpflug imaging
    Kranitz, Kinga
    Kovacs, Illes
    Gyenes, Andrea
    Sandor, Gabor Laszlo
    Juhasz, Eva
    Dienes, Lorant
    Nemeth, Janos
    Nagy, Zoltan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [8] Correlation of corneal elevations measured by Scheimpflug corneal imaging with severity of keratoconus
    Medghalchi, Abdolreza
    Moghadam, Reza Soltani
    Akbari, Mitra
    Alizadeh, Yousef
    Soltanipour, Soheil
    Veisi, Heidar
    Khakpour, Yaser
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2019, 31 (04): : 377 - 381
  • [9] Repeatability of Corneal Deformation Response Parameters by Dynamic Ultra High-speed Scheimpflug Imaging in Normal and Keratoconus Eyes
    Henriquez, Maria A.
    Gomez, Isabel
    Camino-Quezada, Maythe
    Izquierdo, Luis, Jr.
    Chauca, Jose
    Binder, Perry S.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (01): : 14 - 19
  • [10] Evaluation of Scheimpflug imaging parameters in subclinical keratoconus, keratoconus, and normal eyes
    Ucakhan, Omur O.
    Cetinkor, Volkan
    Ozkan, Muhip
    Kanpolat, Ayfer
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (06): : 1116 - 1124