A New Brain Positron Emission Tomography Scanner With Semiconductor Detectors for Target Volume Delineation and Radiotherapy Treatment Planning in Patients With Nasopharyngeal Carcinoma

被引:7
|
作者
Katoh, Norio [1 ]
Yasuda, Koichi [1 ]
Shiga, Tohru [2 ,3 ]
Hasegawa, Masakazu [1 ]
Onimaru, Rikiya [1 ]
Shimizu, Shinichi [1 ]
Bengua, Gerard
Ishikawa, Masayori
Tamaki, Nagara [2 ,3 ]
Shirato, Hiroki [1 ]
机构
[1] Hokkaido Univ, Grad Sch Med, Dept Radiat Med, Sapporo, Hokkaido 0608638, Japan
[2] Hokkaido Univ, Grad Sch Med, Dept Nucl Med, Sapporo, Hokkaido 0608638, Japan
[3] Hokkaido Univ, Grad Sch Med, Dept Med Phys, Sapporo, Hokkaido 0608638, Japan
关键词
Nasopharyngeal carcinoma; Positron emission tomography; Radiotherapy planning; Semiconductor; Target volume delineation; STANDARD UPTAKE VALUE; CELL LUNG-CANCER; NECK-CANCER; TUMOR VOLUME; FDG-PET; HEAD; CT; FUSION; DEFINITION; SPECIMEN;
D O I
10.1016/j.ijrobp.2011.09.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: We compared two treatment planning methods for stereotactic boost for treating nasopharyngeal carcinoma (NPC): the use of conventional whole-body bismuth germanate (BGO) scintillator positron emission tomography (PETCONVWB) versus the new brain (BR) PET system using semiconductor detectors (PETNEWBR). Methods and Materials: Twelve patients with NPC were enrolled in this study. [F-18]Fluorodeoxyglucose-PET images were acquired using both the PETNEWBR and the PETCONVWB system on the same day. Computed tomography (CT) and two PET data sets were transferred to a treatment planning system, and the PETCONVWB and PETNEWBR images were coregistered with the same set of CT images. Window width and level values for all PET images were fixed at 3000 and 300, respectively. The gross tumor volume (GTV) was visually delineated on PET images by using either PETCONVWB (GTV(CONV)) images or PETNEWBR (GTV(NEW)) images. Assuming a stereotactic radiotherapy boost of 7 ports, the prescribed dose delivered to 95% of the planning target volume (PTV) was set to 2000 cGy in 4 fractions. Results: The average absolute volume (+/- standard deviation [SD]) of GTV(NEW) was 15.7 ml (+/- 9.9) ml, and that of GTV(CONV) was 34.0 (+/- 20.5) ml. The average GTV(NEW) was significantly smaller than that of GTV(CONV) (p = 0.0006). There was no statistically significant difference between the maximum dose (p = 0.0585) and the mean dose (p = 0.2748) of PTV. The radiotherapy treatment plan based on the new gross tumor volume (PLAN(NEW)) significantly reduced maximum doses to the cerebrum and cerebellum (p = 0.0418) and to brain stem (p = 0.0041). Conclusion: Results of the present study suggest that the new brain PET system using semiconductor detectors can provide more accurate tumor delineation than the conventional whole-body BGO PET system and may be an important tool for functional and molecular radiotherapy treatment planning. (C) 2012 Elsevier Inc.
引用
收藏
页码:E671 / E676
页数:6
相关论文
共 50 条
  • [1] A new positron emission tomography with semiconductor detectors for target volume delineation and radiotherapy treatment planning in patients with nasopharyngeal carcinoma
    Katoh, N.
    Shiga, T.
    Hasegawa, M.
    Onimaru, R.
    Yasuda, K.
    Shimizu, S.
    Bengua, G.
    Ishikawa, M.
    Tamaki, N.
    Shirato, H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S589 - S590
  • [2] The Role of Positron Emission Tomography Imaging in Radiotherapy Target Delineation
    Menon, Hari
    Guo, Chunxiao
    Verma, Vivek
    Simone, Charles B., II
    PET CLINICS, 2020, 15 (01) : 45 - +
  • [3] Positron emission tomography and radiotherapy treatment planning
    Demir, Bayram
    Okutan, Murat
    Demir, Mustafa
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2009, 24 (02): : 88 - 97
  • [4] Influence of MRI on target volume delineation and IMRT planning in nasopharyngeal carcinoma
    Emami, B
    Sethi, A
    Petruzzelli, GJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (02): : 481 - 488
  • [5] The impact of positron emission tomography in the radiotherapy treatment planning -: Minireview
    Dolezelova, H.
    Slampa, P.
    NEOPLASMA, 2007, 54 (02) : 95 - 100
  • [6] Adaptive 18Fluoro-2-deoxyglucose Positron Emission Tomography/Computed Tomography-based Target Volume Delineation in Radiotherapy Planning of Head and Neck Cancer
    Moule, R. N.
    Kayani, I.
    Prior, T.
    Lemon, C.
    Goodchild, K.
    Sanghera, B.
    Wong, W. L.
    Saunders, M. I.
    CLINICAL ONCOLOGY, 2011, 23 (05) : 364 - 371
  • [7] Comparison of three image segmentation techniques for target volume delineation in positron emission tomography
    Drever, Laura
    Roa, Wilson
    McEwan, Alexander
    Robinson, Don
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (02): : 93 - 109
  • [8] Technical Aspects of Positron Emission Tomography/Computed Tomography in Radiotherapy Treatment Planning
    Scripes, Paola G.
    Yaparpalvi, Ravindra
    SEMINARS IN NUCLEAR MEDICINE, 2012, 42 (05) : 283 - 288
  • [9] Positron emission tomography with computed tomography imaging (PET/CT) for the radiotherapy planning definition of the biological target volume: PART 2
    Fiorentino, Alba
    Laudicella, Riccardo
    Ciurlia, Elisa
    Annunziata, Salvatore
    Lancellotta, Valentina
    Mapelli, Paola
    Tuscano, Carmelo
    Caobelli, Federico
    Evangelista, Laura
    Marino, Lorenza
    Quartuccio, Natale
    Fiore, Michele
    Borghetti, Paolo
    Chiaravalloti, Agostino
    Ricci, Maria
    Desideri, Isacco
    Alongi, Pierpaolo
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2019, 139 : 117 - 124
  • [10] Positron emission tomography with computed tomography imaging (PET/CT) for the radiotherapy planning definition of the biological target volume: PART 1
    Alongi, Pierpaolo
    Laudicella, Riccardo
    Desideri, Isacco
    Chiaravalloti, Agostino
    Borghetti, Paolo
    Quartuccio, Natale
    Fiore, Michele
    Evangelista, Laura
    Marino, Lorenza
    Caobelli, Federico
    Tuscano, Carmelo
    Mapelli, Paola
    Lancellotta, Valentina
    Annunziata, Salvatore
    Ricci, Maria
    Ciurlia, Elisa
    Fiorentino, Alba
    CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2019, 140 : 74 - 79