Reduced susceptibility effects in perfusion fMRI with single-shot spin-echo EPI acquisitions at 1.5 Tesla

被引:62
|
作者
Wang, JJ [1 ]
Li, L
Roc, AC
Alsop, DC
Tang, K
Butler, NS
Schnall, MD
Detre, JA
机构
[1] Univ Penn, Dept Radiol, Metab Magnet Resonance Res & Comp Ctr, Philadelphia, PA 19104 USA
[2] Univ Penn, Dept Neurol, Philadelphia, PA 19104 USA
[3] Harvard Univ, Sch Med, Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02115 USA
关键词
arterial spin label; susceptibility artifacts; spin-echo EPI; perfusion fMRI;
D O I
10.1016/S0730-725X(03)00210-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Arterial spin labeling (ASL) perfusion contrast is not based on susceptibility effects and can therefore be used to study brain function in regions of high static inhornogeneity. As a proof of concept, single-shot spin-echo echo-planar imaging (EPI) acquisition was carried out with a multislice continuous ASL (CASL) method at 1.5T. A bilateral finger tapping paradigm was used in the presence of an exogenously induced susceptibility artifact over left motor cortex. The spin-echo CASL technique was compared with a regular gradient-echo EPI sequence with the same slice thickness, as well as other imaging methods using thin slices and spin-echo acquisitions. The results demonstrate improved functional sensitivity and efficiency of the spin-echo CASL approach as compared with gradient-echo EPI techniques, and a trend of improved sensitivity as compared with spin-echo EPI approach in the brain regions affected by the susceptibility artifact. ASL images, either with or without subtraction of the control, provide a robust alternative to blood oxygenation level dependant (BOLD) methods for activation imaging in regions of high static field inhomogeneity. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 50 条
  • [21] MR cholangiopancreatography: Comparison between single-shot turbo spin-echo sequence and three-dimensional turbo spin-echo sequence with SENSE technique
    Yun, EJ
    Choi, CS
    Park, SJ
    Bae, SH
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2004, 182 (04) : 54 - 54
  • [22] Cerebral Microvascular Perfusion Assessed in Elderly Adults by Spin-Echo Dynamic Susceptibility Contrast MRI at 7 Tesla
    Elschot, Elles P.
    Backes, Walter H.
    van den Kerkhof, Marieke
    Postma, Alida A.
    Kroon, Abraham A.
    Jansen, Jacobus F. A.
    TOMOGRAPHY, 2024, 10 (01) : 181 - 192
  • [23] Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging
    Hori, M
    Murakami, T
    Kim, T
    Kanematsu, M
    Tsuda, K
    Takahashi, S
    Takamura, M
    Hoshi, H
    Nakamura, H
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) : 1423 - 1431
  • [24] Single-shot fast spin-echo diffusion tensor imaging of the brain and spine with head and phased array coils at 1.5 T and 3.0 T
    Xu, D
    Henry, RG
    Mukherjee, P
    Carvajal, L
    Miller, SP
    Barkovich, AJ
    Vigneron, DB
    MAGNETIC RESONANCE IMAGING, 2004, 22 (06) : 751 - 759
  • [25] Three-dimensional fast-recovery fast spin-echo MRCP: Comparison with two-dimensional single-shot fast spin-echo techniques
    Sodickson, A
    Mortele, KJ
    Barish, MA
    Zou, KH
    Thibodeau, S
    Tempany, CMC
    RADIOLOGY, 2006, 238 (02) : 549 - 559
  • [26] MR cholangiopancreatography of bile and pancreatic duct abnormalities with emphasis on the single-shot fast spin-echo technique
    Vitellas, KM
    Keogan, MT
    Spritzer, CE
    Nelson, RC
    RADIOGRAPHICS, 2000, 20 (04) : 939 - 957
  • [27] Clinical application of single-shot fast spin-echo sequence for cerebrospinal fluid flow MR imaging
    Bessho, Takahito
    Hayashi, Tatsuya
    Shibukawa, Shuhei
    Kourin, Kazuyuki
    Shouda, Takashi
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (03) : 782 - 792
  • [28] Sensitivity-encoded single-shot spiral imaging for reduced susceptibility artifacts in BOLD fMRI
    Weiger, M
    Pruessmann, KP
    Österbauer, R
    Börnert, P
    Boesiger, P
    Jezzard, P
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (05) : 860 - 866
  • [29] Comparison of multislice half-Fourier acquisition single-shot turbo spin-echo (HASTE) and single slab turbo spin-echo (SSTSE) with super long echo time in MR cholangiopancreatography (MRCP)
    Morrin, MM
    Farrell, RJ
    MacMathuna, P
    Stack, JP
    Murray, J
    RADIOLOGY, 1997, 205 : 1524 - 1524
  • [30] Motion correction of parametric fMRI data from multi-slice single-shot multi-echo acquisitions
    Speck, O
    Hennig, J
    MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (05) : 1023 - 1027