Module for measurement of CO2 concentration in exhaled air

被引:0
|
作者
Puton, JW [1 ]
Palko, T [1 ]
Knap, A [1 ]
Jasek, K [1 ]
Siodlowski, B [1 ]
机构
[1] Mil Univ Technol, PL-00908 Warsaw, Poland
关键词
non-dispersive infrared gas analysis; carbon dioxide; capnometry; calibration;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The objective of this work consists in working out of a detection module for capnography (carbon dioxide concentration measurement in anaesthesiology and intensive care). The principle of operation of the module consists of the NDIR method. The basic assumption for construction of this model was using of directly modulated thermal IR source in it. A few models of IR sources were worked out. Their heaters were made from thick platinum layers and foil. Limits of modulation frequency for IR sources were greater than 30 Hz. The detection module consists of an optical-part, analogue electronics and microprocessor system with a suitable program. The time dependent concentration of CO2, end tidal concentration Of CO2, mean concentration of N2O and breath frequency are output values of the detection module. Measurements are executed 30 times per second. The accuracy Of CO2 Concentration measurement equals to 5%.
引用
下载
收藏
页码:278 / 282
页数:5
相关论文
共 50 条
  • [1] STUDIES ON ORIGIN OF CO2 IN EXHALED AIR
    KOVATS, J
    BARANKAY, A
    KULKA, F
    BULLETIN DE PHYSIO-PATHOLOGIE RESPIRATOIRE, 1975, 11 (03): : P180 - P181
  • [3] Measurement of the 13CO2/12CO2 concentration ratio in exhaled air by diode laser spectroscopy
    E. S. Mironchuk
    Bulletin of the Lebedev Physics Institute, 2010, 37 : 180 - 181
  • [5] Design of a gas sampling module for CO2 concentration measurement in fast response conditions
    Kim, WS
    Lee, JH
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2005, 16 (05) : 1145 - 1149
  • [6] MEASUREMENT AND SIMULATION OF INDOOR AIR QUALITY AND CO2 CONCENTRATION IN A HOTEL ROOM
    Asadi, Ehsan
    da Silva, Manuel Gameiro
    Costa, Jose J.
    PROCEEDINGS OF THE ASME 10TH BIENNIAL CONFERENCE ON ENGINEERING SYSTEMS DESIGN AND ANALYSIS, 2010, VOL 4, 2010, : 545 - 554
  • [7] CO2 measurement module for flue gas analysis
    不详
    ZKG INTERNATIONAL, 2004, 57 (12): : 11 - 11
  • [8] CORRELATION BETWEEN BRONCHIAL CIRCULATION AND CO2 CONTENT OF EXHALED AIR
    KOVATS, J
    KECSKES, A
    KULKA, F
    PENZES, I
    BULLETIN EUROPEEN DE PHYSIOPATHOLOGIE RESPIRATOIRE-CLINICAL RESPIRATORY PHYSIOLOGY, 1976, 12 (06): : P243 - P243
  • [9] Concentration of exhaled breath condensate biomarkers after fractionated collection based on exhaled CO2 signal
    Goldoni, Matteo
    Corradi, Massimo
    Mozzoni, Paola
    Folesani, Giuseppina
    Alinovi, Rossella
    Pinelli, Silvana
    Andreoli, Roberta
    Pigini, Daniela
    Tillo, Raffaella
    Filetti, Angela
    Garavelli, Claudia
    Mutti, Antonio
    JOURNAL OF BREATH RESEARCH, 2013, 7 (01)
  • [10] Effect of elevated air CO2 concentration on the CO2 assimilation of winter wheat
    Harnos, N
    Szente, K
    Tuba, Z
    PHOTOSYNTHESIS: MECHANISMS AND EFFECTS, VOLS I-V, 1998, : 3491 - 3494