In vivo and 3D visualization of coronary artery development by optical coherence tomography

被引:0
|
作者
Thrane, L. [1 ]
Norozi, K. [2 ]
Maenner, J. [3 ]
Pedersen, F. [1 ]
Mottl-Link, S. [4 ]
Larsen, H. Engelbrecht [1 ]
Andersen, P. E. [1 ]
Wessel, A. [2 ]
Yelbuz, T. M. [2 ]
机构
[1] Tech Univ Denmark, Riso Natl Lab, Opt & Plasma Res Dept, POB 49, DK-4000 Roskilde, Denmark
[2] Hannover Med Sch, Dept Pediat Cardiol & Intens Care Med, D-30623 Hannover, Germany
[3] Georg August Univ Gottingen, Dept Anat & Embryol, D-37075 Gottingen, Germany
[4] German Canc Res Ctr, Dept Med & Biol Informat, D-69121 Heidelberg, Germany
关键词
optical coherence tomography; optical Doppler tomography; coronary artery development;
D O I
10.1117/12.727823
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
One of the most critical but poorly understood processes during cardiovascular development is the establishment of a functioning coronary artery (CA) system. Due to the lack of suitable imaging technologies, it is currently impossible to visualize this complex dynamic process on living human embryos. Furthermore, due to methodological limitations, this intriguing process has not been unveiled in living animal embryos, too. We present here, to the best of our knowledge, the first in vivo images of developing CAs obtained from the hearts of chick embryos grown in shell-less cultures. The in vivo images were generated by optical coherence tomography (OCT). The OCT system used in this study is a mobile fiber-based time-domain real-time OCT system operating with a center wavelength of 1330 nm, an A-scan rate of 4 kHz, and a typical frame rate of 8 frames/s. The axial resolution is 17 mu m (in tissue), and the lateral resolution is 30 mu m. The OCT system is optimized for in vivo chick heart visualization and enables OCT movie recording with 8 frames/s, full-automatic 3D OCT scanning, and blood flow visualization, i.e., Doppler OCT imaging. Using this OCT system, we generated in vivo OCT recordings of chick embryo hearts to study the process of connection of the future right coronary artery (RCA) to the aorta. Recordings were made at three critical stages during development: day 8 (no clear connection yet), day 9 (established connection of RCA with the aorta with clear blood flow) and day 10 (further remodeling of the established RCA).
引用
收藏
页数:5
相关论文
共 50 条
  • [31] Computational 3D microscopy with optical coherence refraction tomography
    Zhou, Kevin C.
    McNabb, Ryan P.
    Qian, Ruobing
    Degan, Simone
    Dhalla, Al-Hafeez
    Farsiu, Sina
    Izatt, Joseph A.
    OPTICA, 2022, 9 (06): : 593 - 601
  • [32] In-vivo characterization of plaque morphology by optical coherence tomography predicts coronary artery remodeling
    Mac Neill, BD
    Lowe, HC
    Pomeranstev, E
    DeJoseph, D
    Yabushita, H
    Tearney, GJ
    Bouma, BE
    Jang, IK
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 42A - 42A
  • [33] Spontaneous Recanalization of a Coronary Artery After Thrombotic Occlusion In Vivo Demonstration With Optical Coherence Tomography
    Cho, Jin-Man
    Raffel, Owen C.
    Stone, James R.
    Kim, Chong-Jin
    Jang, Ik-Kyung
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (12) : 1274 - 1274
  • [34] Diagnosis of Occlusal Tooth Wear Using 3D Imaging of Optical Coherence Tomography Ex Vivo
    Kashiwa, Misa
    Shimada, Yasushi
    Sadr, Alireza
    Yoshiyama, Masahiro
    Sumi, Yasunori
    Tagami, Junji
    SENSORS, 2020, 20 (21) : 1 - 14
  • [35] Automated in vivo 3D High-Definition Optical Coherence Tomography Skin Analysis System
    Yow, Ai Ping
    Cheng, Jun
    Li, Annan
    Srivastava, Ruchir
    Liu, Jiang
    Wong, Damon Wing Kee
    Tey, Hong Liang
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 3895 - 3898
  • [36] CMOS optoelectronic spectrometer based on photonic integrated circuit for in vivo 3D optical coherence tomography
    Agneter, Anja
    Muellner, Paul
    Nguyen, Quang
    Seyringer, Dana
    Rank, Elisabet A.
    Vlaskovic, Marko
    Kraft, Jochen
    Sagmeister, Martin
    Nevlacsil, Stefan
    Eggeling, Moritz
    Maese-Novo, Alejandro
    Morozov, Yevhenii
    Schmitner, Nicole
    Kimmel, Robin A.
    Bodenstorfer, Ernst
    Cipriano, Pietro
    Zimmermann, Horst
    Leitgeb, Rainer A.
    Hainberger, Rainer
    Drexler, Wolfgang
    PhotoniX, 2024, 5 (01)
  • [37] Enhanced 3D visualization of human fallopian tube morphology using a miniature optical coherence tomography catheter
    Luo, Hongbo
    Li, Shuying
    Kou, Sitai
    Lin, Yixiao
    Hagemann, Ian S.
    Zhu, Quing
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (07) : 3225 - 3233
  • [38] 3D visualization techniques and its usefulness of eyeground images data sets generated by Optical Coherence Tomography
    Ito, F
    Doi, A
    Tokuda, M
    11th International Conference on Parallel and Distributed Systems Workshops, Vol II, Proceedings,, 2005, : 219 - 223
  • [39] 3D visualization of the orientation columns in cat primary visual cortex using functional optical coherence tomography
    Nakamichi, Yu
    Kalatsky, Valery A.
    Watanabe, Hideyuki
    Rajagopalan, Uma Maheswari
    Tanifuji, Manabu
    NEUROSCIENCE RESEARCH, 2011, 71 : E69 - E70
  • [40] Rapid automated lumen segmentation of coronary optical coherence tomography images followed by 3D reconstruction of coronary arteries
    Wu, Wei
    Roby, Merjulah
    Banga, Akshat
    Oguz, Usama M.
    Gadamidi, Vinay Kumar
    Hasini Vasa, Charu
    Zhao, Shijia
    Dasari, Vineeth S.
    Thota, Anjani Kumar
    Tanweer, Sartaj
    Lee, Changkye
    Kassab, Ghassan S.
    Chatzizisis, Yiannis S.
    JOURNAL OF MEDICAL IMAGING, 2024, 11 (01)