Rapid automated lumen segmentation of coronary optical coherence tomography images followed by 3D reconstruction of coronary arteries

被引:0
|
作者
Wu, Wei [1 ]
Roby, Merjulah [2 ]
Banga, Akshat [1 ]
Oguz, Usama M. [1 ]
Gadamidi, Vinay Kumar [1 ]
Hasini Vasa, Charu [1 ]
Zhao, Shijia [1 ]
Dasari, Vineeth S. [1 ]
Thota, Anjani Kumar [1 ]
Tanweer, Sartaj [1 ]
Lee, Changkye [1 ]
Kassab, Ghassan S. [3 ]
Chatzizisis, Yiannis S. [1 ]
机构
[1] Univ Miami, Ctr Digital Cardiovasc Innovat, Miller Sch Med, Div Cardiovasc Med, Miami, FL 33136 USA
[2] Univ Texas San Antonio, Dept Mech Engn Vasc Biomech & Biofluids, San Antonio, TX USA
[3] Calif Med Innovat Inst, San Diego, CA USA
基金
美国国家卫生研究院;
关键词
optical coherence tomography; image segmentation; nonuniform rational B-spline; three-dimensional reconstruction; OCT; ACCURATE;
D O I
10.1117/1.JMI.11.1.014004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Optical coherence tomography has emerged as an important intracoronary imaging technique for coronary artery disease diagnosis as it produces high-resolution cross-sectional images of luminal and plaque morphology. Precise and fast lumen segmentation is essential for efficient OCT morphometric analysis. However, due to the presence of various image artifacts, including side branches, luminal blood artifacts, and complicated lesions, this remains a challenging task. Approach: Our research study proposes a rapid automatic segmentation method that utilizes nonuniform rational B-spline to connect limited pixel points and identify the edges of the OCT lumen. The proposed method suppresses image noise and accurately extracts the lumen border with a high correlation to ground truth images based on the area, minimal diameter, and maximal diameter. Results: We evaluated the method using 3300 OCT frames from 10 patients and found that it achieved favorable results. The average time taken for automatic segmentation by the proposed method is 0.17 s per frame. Additionally, the proposed method includes seamless vessel reconstruction following the lumen segmentation. Conclusions: The developed automated system provides an accurate, efficient, robust, and user-friendly platform for coronary lumen segmentation and reconstruction, which can pave the way for improved assessment of the coronary artery lumen morphology. (c) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License.Distribution or reproduction of this work in whole or in part requires full attribution of the originalpublication, including its DOI.
引用
收藏
页数:20
相关论文
共 50 条
  • [1] 3D Reconstruction of Coronary Arteries using Frequency Domain Optical Coherence Tomography Images and Biplane Angiography
    Athanasiou, L. S.
    Bourantas, C. V.
    Siogkas, P. K.
    Sakellarios, A. I.
    Exarchos, T. P.
    Naka, K. K.
    Papafaklis, M. I.
    Michalis, L. K.
    Prati, F.
    Fotiadis, D. I.
    [J]. 2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, : 2647 - 2650
  • [2] Automated 3D Reconstruction and Segmentation from Optical Coherence Tomography
    Eichel, Justin A.
    Bizheva, Kostadinka K.
    Clausi, David A.
    Fieguth, Paul W.
    [J]. COMPUTER VISION-ECCV 2010, PT III, 2010, 6313 : 44 - +
  • [3] Fully automated lumen segmentation of intracoronary optical coherence tomography images
    Athanasiou, L. S.
    Rikhtegar, Farhad
    Galon, Micheli Zanotti
    Lopes, Augusto Celso
    Lemos, Pedro Alves
    Edelman, Elazer R.
    [J]. MEDICAL IMAGING 2017: IMAGE PROCESSING, 2017, 10133
  • [4] Reconstruction of stented coronary arteries from optical coherence tomography images: Feasibility, validation, and repeatability of a segmentation method
    Chiastra, Claudio
    Montin, Eros
    Bologna, Marco
    Migliori, Susanna
    Aurigemma, Cristina
    Burzotta, Francesco
    Celi, Simona
    Dubini, Gabriele
    Migliavacca, Francesco
    Mainardi, Luca
    [J]. PLOS ONE, 2017, 12 (06):
  • [5] Automated analysis of fibrous cap in intravascular optical coherence tomography images of coronary arteries
    Lee, Juhwan
    Pereira, Gabriel T. R.
    Gharaibeh, Yazan
    Kolluru, Chaitanya
    Zimin, Vladislav N.
    Dallan, Luis A. P.
    Kim, Justin N.
    Hoori, Ammar
    Al-Kindi, Sadeer G.
    Guagliumi, Giulio
    Bezerra, Hiram G.
    Wilson, David L.
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01):
  • [6] Automated analysis of fibrous cap in intravascular optical coherence tomography images of coronary arteries
    Juhwan Lee
    Gabriel T. R. Pereira
    Yazan Gharaibeh
    Chaitanya Kolluru
    Vladislav N. Zimin
    Luis A. P. Dallan
    Justin N. Kim
    Ammar Hoori
    Sadeer G. Al-Kindi
    Giulio Guagliumi
    Hiram G. Bezerra
    David L. Wilson
    [J]. Scientific Reports, 12 (1)
  • [7] Automatic Plaque Segmentation in Coronary Optical Coherence Tomography Images
    Zhang, Huaqi
    Wang, Guanglei
    Li, Yan
    Lin, Feng
    Han, Yechen
    Wang, Hongrui
    [J]. INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 2019, 33 (14)
  • [8] Knowledge-based 3D segmentation and reconstruction of coronary arteries using CT images
    Yang, Y
    Tannenbaum, A
    Giddens, D
    [J]. PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 1664 - 1666
  • [9] Optical Coherence Tomography of Coronary Arteries
    Roland, Robert
    Veselka, Josef
    [J]. INTERNATIONAL JOURNAL OF ANGIOLOGY, 2021, 30 (01) : 29 - 39
  • [10] 3D reconstruction of coronary arteries and atherosclerotic plaques based on computed tomography angiography images
    Kigka, Vassiliki I.
    Rigas, George
    Sakellarios, Antonis
    Siogkas, Panagiotis
    Andrikos, Ioannis O.
    Exarchos, Themis P.
    Loggitsi, Dimitra
    Anagnostopoulos, Constantinos D.
    Michalis, Lampros K.
    Neglia, Danilo
    Pelosi, Gualtriero
    Parodi, Oberdan
    Fotiadis, Dimitrios I.
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2018, 40 : 286 - 294