Rapid automated lumen segmentation of coronary optical coherence tomography images followed by 3D reconstruction of coronary arteries

被引:0
|
作者
Wu, Wei [1 ]
Roby, Merjulah [2 ]
Banga, Akshat [1 ]
Oguz, Usama M. [1 ]
Gadamidi, Vinay Kumar [1 ]
Hasini Vasa, Charu [1 ]
Zhao, Shijia [1 ]
Dasari, Vineeth S. [1 ]
Thota, Anjani Kumar [1 ]
Tanweer, Sartaj [1 ]
Lee, Changkye [1 ]
Kassab, Ghassan S. [3 ]
Chatzizisis, Yiannis S. [1 ]
机构
[1] Univ Miami, Ctr Digital Cardiovasc Innovat, Miller Sch Med, Div Cardiovasc Med, Miami, FL 33136 USA
[2] Univ Texas San Antonio, Dept Mech Engn Vasc Biomech & Biofluids, San Antonio, TX USA
[3] Calif Med Innovat Inst, San Diego, CA USA
基金
美国国家卫生研究院;
关键词
optical coherence tomography; image segmentation; nonuniform rational B-spline; three-dimensional reconstruction; OCT; ACCURATE;
D O I
10.1117/1.JMI.11.1.014004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Optical coherence tomography has emerged as an important intracoronary imaging technique for coronary artery disease diagnosis as it produces high-resolution cross-sectional images of luminal and plaque morphology. Precise and fast lumen segmentation is essential for efficient OCT morphometric analysis. However, due to the presence of various image artifacts, including side branches, luminal blood artifacts, and complicated lesions, this remains a challenging task. Approach: Our research study proposes a rapid automatic segmentation method that utilizes nonuniform rational B-spline to connect limited pixel points and identify the edges of the OCT lumen. The proposed method suppresses image noise and accurately extracts the lumen border with a high correlation to ground truth images based on the area, minimal diameter, and maximal diameter. Results: We evaluated the method using 3300 OCT frames from 10 patients and found that it achieved favorable results. The average time taken for automatic segmentation by the proposed method is 0.17 s per frame. Additionally, the proposed method includes seamless vessel reconstruction following the lumen segmentation. Conclusions: The developed automated system provides an accurate, efficient, robust, and user-friendly platform for coronary lumen segmentation and reconstruction, which can pave the way for improved assessment of the coronary artery lumen morphology. (c) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License.Distribution or reproduction of this work in whole or in part requires full attribution of the originalpublication, including its DOI.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Automatic vessel lumen segmentation in optical coherence tomography (OCT) images
    Zhang, Huaizhong
    Essa, Ehab
    Xie, Xianghua
    [J]. APPLIED SOFT COMPUTING, 2020, 88
  • [32] A Statistical Model for 3D Segmentation of Retinal Choroid in Optical Coherence Tomography Images
    Ghasemi, F.
    Rabbani, H.
    [J]. MEDICAL IMAGING 2014: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2014, 9038
  • [33] Automatic Segmentation of Vessel Lumen in Intravascular Optical Coherence Tomography Images
    Wang, Ancong
    Tang, Xiaoying
    [J]. 2016 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION, 2016, : 948 - 953
  • [34] Automated detection of calcified plaques in coronary optical coherence tomography images using image segmentation based on machine learning
    Gangl, C.
    Roth, C.
    Dalos, D.
    Delle-Karth, G.
    Neunteufl, T.
    Berger, R.
    [J]. EUROPEAN HEART JOURNAL, 2019, 40 : 3499 - 3499
  • [35] Automated detection of calcified plaques in coronary optical coherence tomography images using image segmentation based on machine learning
    Gangl, Clemens
    Roth, Christian
    Dalos, Daniel
    Delle-Karth, Georg
    Neunteufl, Thomas
    Berger, Rudolf
    [J]. WIENER KLINISCHE WOCHENSCHRIFT, 2019, 131 : 320 - 321
  • [36] A Fully Automated Framework for Segmentation and Stenosis Quantification of Coronary Arteries in 3D CTA Imaging
    Wang, Yin
    Liatsis, Panos
    [J]. 2009 SECOND INTERNATIONAL CONFERENCE ON DEVELOPMENTS IN ESYSTEMS ENGINEERING (DESE 2009), 2009, : 136 - 140
  • [37] Optimal 3D reconstruction of coronary arteries for 3D clinical assessment
    Fallavollita, Pascal
    Cheriet, Farida
    [J]. COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2008, 32 (06) : 476 - 487
  • [38] AUTOMATED TRACKING AND 3D RECONSTRUCTION OF CORONARY VASCULATURE
    POPE, DL
    PARKER, DL
    VANBREE, RE
    [J]. MEDICAL PHYSICS, 1986, 13 (04) : 597 - 597
  • [39] Automated Segmentation of the Choroid in Retinal Optical Coherence Tomography Images
    Lu, Huiqi
    Boonarpha, Nattapon
    Kwong, Man Ting
    Zheng, Yalin
    [J]. 2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 5869 - 5872
  • [40] Simultaneous segmentation and tree reconstruction of the coronary arteries in MSCT images
    Lorenz, C
    Renisch, S
    Schlathölter, T
    Bülow, T
    [J]. MEDICAL IMAGING 2003: PHYSIOLOGY AND FUNCTION: METHODS, SYSTEMS, AND APPLICATIONS, 2003, 5031 : 167 - 177