First measurement of VUV spectroscopy using 1 m normal incidence spectrometer on HL-2A

被引:4
|
作者
Cui Zhengying [1 ]
Sun Ping [1 ]
Dong Jiafu [1 ]
Huang Yuan [1 ]
Wang Quanming [1 ]
Fu Bingzhong [1 ]
Lu Jie [1 ]
Chen Wei [1 ]
Duan Xuru [1 ]
Ding Xuantong [1 ]
Yang Qingwei [1 ]
Morita, S. [2 ]
机构
[1] SW Inst Phys, Chengdu 610041, Peoples R China
[2] Natl Inst Nat Sci, Natl Inst Fus Sci, Toki, Gifu 5095292, Japan
关键词
VUV spectroscopy; line emission; CCD;
D O I
10.1088/1009-0630/10/3/06
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
A 1 m vacuum ultraviolet (VUV) spectrometer with temporal and spatial resolution was developed for impurity study of HL-2A tokamak. The instrument is equipped with two concave gratings blazed at 80 nm and 150 nm, respectively, and a windowless back-illuminated charge coupled device (CCD) detector of 256 x 1024 pixels. The total wavelength coverage of spectrometer is 30 similar to 320 nm with a spectral resolution of 0.015 nm at a width of entrance slit of 10 mu m. A portion of this range is observed during a plasma discharge with a spectral range of 20 nm. The minimum integration time of the detector system is about 6.7 ms for each frame in a full binning mode. Using a space-resolved slit located between the entrance slit and the grating a radial pro. le on the vertical direction with a range of 400 mm can be obtained. The primary results were successfully obtained with high signal-to-noise ratio and good spectral resolution, which demonstrated the instrument functions very well.
引用
收藏
页码:298 / 301
页数:4
相关论文
共 50 条
  • [31] The tri-band high spectral resolution spectrometer with gratings in tandem for the charge-exchange recombination spectroscopy diagnostic system on HL-2A tokamak
    刘亮
    余德良
    马倩
    何小斐
    Maarten DE BOCK
    Manfred von HELLERMANN
    Michael WALSH
    陈文锦
    何小雪
    魏彦玲
    张能
    李栋
    魏会领
    the HLA Team
    Plasma Science and Technology, 2024, 26 (06) : 108 - 115
  • [32] The tri-band high spectral resolution spectrometer with gratings in tandem for the charge-exchange recombination spectroscopy diagnostic system on HL-2A tokamak
    刘亮
    余德良
    马倩
    何小斐
    Maarten DE BOCK
    Manfred von HELLERMANN
    Michael WALSH
    陈文锦
    何小雪
    魏彦玲
    张能
    李栋
    魏会领
    the HL-2A Team
    Plasma Science and Technology, 2024, (06) : 108 - 115
  • [33] Use of dual-pulse laser-induced breakdown spectroscopy for characterization of the laser cleaning of a first mirror exposed in HL-2A
    Hai, Ran
    Wu, Xingwei
    Xin, Yu
    Liu, Ping
    Wu, Ding
    Ding, Hongbin
    Zhou, Yan
    Cai, Laizhong
    Yan, Longwen
    JOURNAL OF NUCLEAR MATERIALS, 2014, 447 (1-3) : 9 - 14
  • [34] Measurement of the Plasma Rotation Velocity by Using Visible Spectrum on HL-1M
    Mukhin E.E.
    中国核科技报告, 1999, (S3) : 34 - 38
  • [35] Measurement of the Plasma Rotation Velocity by Using Visible Spectrum on HL-1M Mokamak
    罗俊林
    李伟
    王恩耀
    董贾福
    唐年益
    刘泽田
    Plasma Science & Technology, 2001, (02) : 683 - 690
  • [36] Measurement of X-rays using mercuric iodide detector in HL-1M tokamak
    Yang, Jinwei
    Zhang, Guangyang
    Zhang, Wei
    Zeng, Qingxi
    Li, Zhenghui
    Li, Weitang
    Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 1997, 17 (02): : 103 - 107
  • [37] Development of high-speed vacuum ultraviolet spectroscopy using a modified Seya-Namioka monochromator and channel electron multiplier detector in the HL-2A tokamak
    Zhang, Kai
    Zheng, Dianlin
    Sun, Ping
    Cui, Zhengying
    Dong, Chunfeng
    Lu, Ping
    Fu, Bingzhong
    Liu, Zetian
    Shi, Zhongbing
    Yang, Qingwei
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (10):
  • [38] Laser absorption spectrometer using frequency chirped intensity modulation at 1.57 μm wavelength for CO2 measurement
    Imaki, Masaharu
    Kameyama, Shumpei
    Hirano, Yoshihito
    Ueno, Shinichi
    Sakaizawa, Daisuke
    Kawakami, Shuji
    Nakajima, Masakatsu
    OPTICS LETTERS, 2012, 37 (13) : 2688 - 2690
  • [39] First study on iron complexes in blood and organ samples from thalassaemic and normal laboratory mice using Mössbauer spectroscopy
    George Charitou
    Vlassis Petousis
    Charalambos Tsertos
    Yannis Parpottas
    Marina Kleanthous
    Marios Phylactides
    Soteroula Christou
    European Biophysics Journal, 2018, 47 : 131 - 138
  • [40] Simultaneous measurement of carbon monoxide and carbon dioxide for combustion diagnosis using 2 μm laser absorption spectroscopy
    Li, Jinyi
    Wang, Keming
    Zhou, Yun
    Wang, Zehua
    Ji, Yue
    Du, Zhenhui
    Yang, Xiaotao
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2024, 66 (11)