Simultaneous measurement of carbon monoxide and carbon dioxide for combustion diagnosis using 2 μm laser absorption spectroscopy

被引:0
|
作者
Li, Jinyi [1 ]
Wang, Keming [1 ]
Zhou, Yun [1 ]
Wang, Zehua [2 ]
Ji, Yue [1 ]
Du, Zhenhui [2 ]
Yang, Xiaotao [3 ]
机构
[1] Tiangong Univ, Sch Control Sci & Engn, Tianjin Key Lab Intelligent Control Elect Equipmen, Tianjin, Peoples R China
[2] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrumen, Tianjin, Peoples R China
[3] Harbin Engn Univ, Coll Power & Energy Engn, Harbin, Peoples R China
基金
中国国家自然科学基金;
关键词
CO detection; CO2; detection; combustion diagnosis; laser absorption spectroscopy; WMS-2f/1f; SENSOR; CO2; TEMPERATURE; H2O; CH4;
D O I
10.1002/mop.70009
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Carbon monoxide (CO) and carbon dioxide (CO2) are products of incomplete combustion and complete combustion, respectively. Time-resolved knowledge of CO and CO2 exhaust concentrations will aid in improving combustion strategies, control, and efficiency. To achieve online high-precision simultaneous measurement of CO and CO2, a tunable diode laser absorption spectroscopy-based sensor is designed and constructed. Two diode lasers with central wavelengths of 2.3 and 2.0 mu m are multiplexed in time-division to cover the absorption spectral lines of CO at 4285.00 cm(-1) and CO2 at 4989.96 cm(-1), respectively. Wavelength modulation spectroscopy with second harmonic detection normalized by the first harmonic (WMS-2f/1f) is employed. A software lock-in amplifier and inversion algorithm are implemented for data processing and concentration acquisition. The entire measurement system is based on the idea of a virtual instrument and is carried out using a high-speed data acquisition card and a computer. Experimental verification demonstrates that the measurement accuracies of CO and CO2 were 2.47% and 2.56%, respectively, with a time resolution of 20 ms. Dynamic measurement experiments with an alcohol blast burner validate the feasibility of measuring CO and CO2 in actual combustion environments. The developed sensor demonstrates the potential for real-time and in situ carbon emission measurement for combustion diagnosis.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Tunable diode laser absorption spectroscopy of carbon monoxide around 2.35 μm
    Nicolas, JC
    Baranov, AN
    Cuminal, Y
    Rouillard, Y
    Alibert, C
    APPLIED OPTICS, 1998, 37 (33) : 7906 - 7911
  • [2] Isotopic resolution of carbon monoxide and carbon dioxide by NIR diode laser spectroscopy
    Lau, Steffen
    Salffner, Katharina
    Loehmannsroeben, Hans-Gerd
    OPTICAL SENSING II, 2006, 6189
  • [3] Simultaneous Determination of Carbon Disulfide, Carbon Monoxide, and Dinitrogen Oxide by Differential Absorption Spectroscopy Using a Distributed Feedback Quantum Cascade Laser
    Cao, Xiu-han
    Li, Jin-yi
    Gao, Hong
    Du, Zhen-hui
    Ma, Yi-wen
    ANALYTICAL LETTERS, 2017, 50 (14) : 2342 - 2350
  • [4] Carbon Monoxide Measurement at Elevated Temperature Based on Tunable Diode Laser Absorption Spectroscopy
    Guo Yan-Lin
    Huang Xiao
    Hong Yi
    Dong Jun-Guo
    Gao Wei
    Li Mei
    Huang Zheng-Xu
    Fu Zhong
    Cheng Ping
    Zhou Zhen
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (08) : 1247 - 1254
  • [5] The simultaneous combustion of hydrogen and carbon monoxide
    Haslam, RT
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1923, 15 : 679 - 681
  • [6] Indoor carbon dioxide monitoring with diode laser absorption at 2 μm
    Li, Jinyi
    Du, Zhenhui
    Ma, Yiwen
    Liu, Jingwang
    THIRD INTERNATIONAL SYMPOSIUM ON LASER INTERACTION WITH MATTER, 2015, 9543
  • [7] Combustion of magnesium with carbon dioxide and carbon monoxide at low gravity
    Abbud-Madrid, A
    Modak, A
    Branch, MC
    Daily, JW
    JOURNAL OF PROPULSION AND POWER, 2001, 17 (04) : 852 - 859
  • [8] Microplasma emission spectroscopy of carbon dioxide using the carbon monoxide Angstrom system
    Persson, Anders
    Berglund, Martin
    JOURNAL OF APPLIED PHYSICS, 2020, 127 (06)
  • [9] CATALYTIC COMBUSTION OF CARBON MONOXIDE ON COPPER OXIDE - EFFECT OF CARBON DIOXIDE
    THOMAS, NT
    CARETTO, LS
    NOBE, K
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1969, 8 (02): : 282 - &
  • [10] Temperature Measurement of Carbon Dioxide Using Fixed-Wavelength Absorption Spectroscopy Technique
    Zhang Yaqi
    Wang Fei
    Cui Haibin
    LASER & OPTOELECTRONICS PROGRESS, 2019, 56 (19)