Simultaneous measurement of carbon monoxide and carbon dioxide for combustion diagnosis using 2 μm laser absorption spectroscopy

被引:0
|
作者
Li, Jinyi [1 ]
Wang, Keming [1 ]
Zhou, Yun [1 ]
Wang, Zehua [2 ]
Ji, Yue [1 ]
Du, Zhenhui [2 ]
Yang, Xiaotao [3 ]
机构
[1] Tiangong Univ, Sch Control Sci & Engn, Tianjin Key Lab Intelligent Control Elect Equipmen, Tianjin, Peoples R China
[2] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrumen, Tianjin, Peoples R China
[3] Harbin Engn Univ, Coll Power & Energy Engn, Harbin, Peoples R China
基金
中国国家自然科学基金;
关键词
CO detection; CO2; detection; combustion diagnosis; laser absorption spectroscopy; WMS-2f/1f; SENSOR; CO2; TEMPERATURE; H2O; CH4;
D O I
10.1002/mop.70009
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Carbon monoxide (CO) and carbon dioxide (CO2) are products of incomplete combustion and complete combustion, respectively. Time-resolved knowledge of CO and CO2 exhaust concentrations will aid in improving combustion strategies, control, and efficiency. To achieve online high-precision simultaneous measurement of CO and CO2, a tunable diode laser absorption spectroscopy-based sensor is designed and constructed. Two diode lasers with central wavelengths of 2.3 and 2.0 mu m are multiplexed in time-division to cover the absorption spectral lines of CO at 4285.00 cm(-1) and CO2 at 4989.96 cm(-1), respectively. Wavelength modulation spectroscopy with second harmonic detection normalized by the first harmonic (WMS-2f/1f) is employed. A software lock-in amplifier and inversion algorithm are implemented for data processing and concentration acquisition. The entire measurement system is based on the idea of a virtual instrument and is carried out using a high-speed data acquisition card and a computer. Experimental verification demonstrates that the measurement accuracies of CO and CO2 were 2.47% and 2.56%, respectively, with a time resolution of 20 ms. Dynamic measurement experiments with an alcohol blast burner validate the feasibility of measuring CO and CO2 in actual combustion environments. The developed sensor demonstrates the potential for real-time and in situ carbon emission measurement for combustion diagnosis.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Intracavity laser absorption spectroscopy with a vertical external cavity surface emitting laser at 2.3 μm:: Application to water and carbon dioxide
    Garnache, A
    Liu, A
    Cerutti, L
    Campargue, A
    CHEMICAL PHYSICS LETTERS, 2005, 416 (1-3) : 22 - 27
  • [32] Cavity enhanced absorption spectroscopy of carbon dioxide using a DFB diode laser and a swept optical cavity
    Pei, SX
    Gao, XM
    Cui, FP
    Haung, W
    Shao, J
    Yang, Y
    Zhang, WJ
    OPTICA APPLICATA, 2004, 34 (04) : 589 - 595
  • [33] Design and Performances of a Carbon Monoxide Sensor Using Mid-Infrared Absorption Spectroscopy Technique at 4.6 μm
    Li, Guo-Lin
    Yan, Zihui
    Song, Nan
    Dong, Ming
    Ye, Wei-Lin
    Zheng, Chuan-Tao
    Wang, Yi-Ding
    SPECTROSCOPY LETTERS, 2015, 48 (06) : 454 - 461
  • [34] Carbon dioxide and ammonia detection using 2 μm diode laser based quartz-enhanced photoacoustic spectroscopy
    R. Lewicki
    G. Wysocki
    A.A. Kosterev
    F.K. Tittel
    Applied Physics B, 2007, 87 : 157 - 162
  • [35] Carbon dioxide and ammonia detection using 2 μm diode laser based quartz-enhanced photoacoustic spectroscopy
    Lewicki, R.
    Wysocki, G.
    Kosterev, A. A.
    Tittel, F. K.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 87 (01): : 157 - 162
  • [36] Small carbon monoxide formation in absorbents does not correlate with small carbon dioxide absorption
    Knolle, E
    Heinze, G
    Gilly, H
    ANESTHESIA AND ANALGESIA, 2002, 95 (03): : 650 - 655
  • [37] Carbon monoxide formation during carbon dioxide absorption in completely dry soda lime
    Knolle, E
    Gilly, H
    ANESTHESIOLOGY, 1999, 91 (3A) : U254 - U254
  • [38] Laser induced breakdown spectroscopy: A potential tool for atmospheric carbon dioxide measurement
    Dikshit, Vivek
    Yueh, Fang-Yu
    Singh, Jagdish P.
    McIntyre, Dustin L.
    Jain, Jinesh C.
    Melikechi, Nouredine
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 68 : 65 - 70
  • [39] Tunable Diode Laser Absorption Spectroscopy Diagnostics of Potassium, Carbon Monoxide, and Soot in Oxygen-Enriched Biomass Combustion Close to Stoichiometry
    Sepman, Alexey
    Ogren, Yngve
    Qu, Zhechao
    Wiinikka, Henrik
    Schmidt, Florian M.
    ENERGY & FUELS, 2019, 33 (11) : 11795 - 11803
  • [40] Femtosecond infrared spectroscopy on bacteriorhodopsin using a broad band carbon monoxide laser
    Dziewior, R
    Diller, R
    BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1996, 100 (12): : 2103 - 2106