High-accuracy calibration of the HXDS flow proportional counter for AXAF at the PTB laboratory at BESSY

被引:12
|
作者
Auerhammer, JM [1 ]
Brandt, G [1 ]
Scholze, F [1 ]
Thomagel, R [1 ]
Ulm, G [1 ]
Wargelin, BJ [1 ]
McDermott, WC [1 ]
Norton, TJ [1 ]
Evans, IN [1 ]
Kellogg, EM [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
来源
关键词
proportional counters; detectors; calibration; x-rays; synchrotron radiation; primary detector standard;
D O I
10.1117/12.331242
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The Smithsonian Astrophysical Observatory uses the HRMA X-ray Detection System (HXDS) to calibrate the High-Resolution Mirror Assembly (HRMA) of the Advanced X-ray Astrophysics Facility AXAF. Apart from two high-purity-germanium solid-state detectors (SSDs) with good energy resolution and very high efficiency at higher energies, the detection sq stem comprises seven now proportional counters (FPCs) and one microchannel-plate High-Speed Imager. For the lower energy range, the FPCs are more appropriate. They have been calibrated at the radiometry laboratory of the Physikalisch-Technische Bundesanstalt, using the electron storage ring BESSY. For the determination of the absolute quantum efficiency two methods have been applied. First, the detector response was measured in the lower energy range 0.1 keV to 1.7 keV at several discrete energies using monochromatized radiation. The absolute photon flux has been determined by Si n-on-p photodiodes, calibrated against a cryogenic electrical-substitution radiometer used as primary detector standard. The second method uses the undispersed synchrotron radiation emitted by a bending magnet of the primary source standard BESSY, which can be calculated very accurately. Combining both measurements the determination of the detection efficiency over the entire desired spectral range (0.1 keV to 10 keV) was possible with a typical relative uncertainty around 1% to 2% in the central energy range (0.2 keV to 1.7 keV).
引用
收藏
页码:19 / 29
页数:11
相关论文
共 50 条
  • [1] High accuracy calibration of the HXDS HPGe detector at the PTB radiometry laboratory at BESSY
    Kraft, S
    Scholze, F
    Thornagel, R
    Ulm, G
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 101 - 112
  • [2] AXAF calibration: The HXDS flow proportional counters
    Wargelin, BJ
    Kellogg, EM
    McDermott, WC
    Evans, IN
    Vitek, SA
    GRAZING INCIDENCE AND MULTILAYER X-RAY OPTICAL SYSTEMS, 1997, 3113 : 526 - 534
  • [3] The new PTB beamlines for high-accuracy EUV reflectometry at BESSY II
    Scholze, F
    Beckhoff, B
    Brandt, G
    Fliegauf, R
    Klein, R
    Meyer, B
    Rost, D
    Schmitz, D
    Veldkamp, M
    Weser, J
    Ulm, G
    Louis, E
    Yakshin, AE
    Oestreich, S
    Bijkerk, F
    SOFT X-RAY AND EUV IMAGING SYSTEMS, 2000, 4146 : 72 - 82
  • [4] Detector calibration at the PTB radiometry laboratory at BESSY
    Rabus, H
    Scholze, F
    Thornagel, R
    Ulm, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3): : 209 - 216
  • [5] Detector calibration at the PTB radiometry laboratory at BESSY
    Physikalisch-Technische, Bundesanstalt, Berlin, Germany
    Nucl Instrum Methods Phys Res Sect A, 2-3 (209-216):
  • [6] High-accuracy detector calibration for EUV metrology at PTB
    Scholze, F
    Brandt, G
    Müller, P
    Meyer, B
    Scholz, F
    Tümmler, J
    Vogel, K
    Ulm, G
    EMERGING LITHOGRAPHIC TECHNOLOGIES VI, PTS 1 AND 2, 2002, 4688 : 680 - 689
  • [7] High-accuracy X-ray detector calibration at PTB
    Krumrey, M
    Scholze, F
    Ulm, G
    HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 : 277 - 285
  • [8] High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory
    Scholze, F
    Henneken, H
    Kuschnerus, P
    Rabus, H
    Richter, M
    Ulm, G
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 866 - 868
  • [9] High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory
    Phys.-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin, Germany
    J. Synchrotron Radiat., 3 (866-868):
  • [10] High-accuracy detector calibration at the PTB four-crystal monochromator beamline
    Krumrey, M
    Ulm, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1175 - 1178