High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory

被引:7
|
作者
Scholze, F [1 ]
Henneken, H [1 ]
Kuschnerus, P [1 ]
Rabus, H [1 ]
Richter, M [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
来源
关键词
photodiodes; detector calibration; soft X-rays; primary detector standards;
D O I
10.1107/S0909049597014076
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
State-of-the-art detector calibration in the UV/VUV and soft Xray spectral ranges at the Physikalisch-Technische Bundesanstalt (PTB) is based on the primary detector standard SYRES, a cryogenic electrical substitution radiometer capable of measuring radiant power of a few mu W. At the PTB radiometry laboratory at the synchrotron radiation facility BESSY, two dedicated beamlines are operated, providing monochromatic radiation of high spectral purity, high radiant power and tunable photon energy in the 3-1500eV range. The spectral responsivity of detectors, e.g. photodiodes, can be measured with a relative uncertainty of about 1% by direct comparison with SYRES, as will be demonstrated for PtSi/Si and GaAsP/Au Schottky and silicon n-on-p photodiodes. The calibration of photon-counting detectors traceable to SYRES can by accomplished by exploiting the unique capability to scale the spectral photon flux over several orders of magnitude by changing the stored electron current. Calibrations of CCDs and photomultipliers are presented as examples.
引用
收藏
页码:866 / 868
页数:3
相关论文
共 50 条
  • [1] High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory
    Phys.-Technische Bundesanstalt, Abbestrasse 2-12, 10587 Berlin, Germany
    J. Synchrotron Radiat., 3 (866-868):
  • [2] High accuracy calibration of the HXDS HPGe detector at the PTB radiometry laboratory at BESSY
    Kraft, S
    Scholze, F
    Thornagel, R
    Ulm, G
    EUX, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VIII, 1997, 3114 : 101 - 112
  • [3] Detector calibration at the PTB radiometry laboratory at BESSY
    Physikalisch-Technische, Bundesanstalt, Berlin, Germany
    Nucl Instrum Methods Phys Res Sect A, 2-3 (209-216):
  • [4] High-accuracy detector calibration for EUV metrology at PTB
    Scholze, F
    Brandt, G
    Müller, P
    Meyer, B
    Scholz, F
    Tümmler, J
    Vogel, K
    Ulm, G
    EMERGING LITHOGRAPHIC TECHNOLOGIES VI, PTS 1 AND 2, 2002, 4688 : 680 - 689
  • [5] Detector calibration at the PTB radiometry laboratory at BESSY
    Rabus, H
    Scholze, F
    Thornagel, R
    Ulm, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3): : 209 - 216
  • [6] High-accuracy X-ray detector calibration at PTB
    Krumrey, M
    Scholze, F
    Ulm, G
    HIGH-ENERGY DETECTORS IN ASTRONOMY, 2004, 5501 : 277 - 285
  • [7] High-accuracy radiometry in the EUV range at the PTB soft x-ray beamline
    Scholze, F
    Tümmler, J
    Ulm, G
    METROLOGIA, 2003, 40 (01) : S224 - S228
  • [8] High-accuracy detector calibration at the PTB four-crystal monochromator beamline
    Krumrey, M
    Ulm, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 1175 - 1178
  • [9] High-accuracy X-ray detector calibration based on cryogenic radiometry
    Krumrey, M.
    Cibik, L.
    Mueller, P.
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 826 - 829
  • [10] Photon Detector Calibration in the EUV spectral range at PTB
    Laubis, C.
    Babalik, A.
    Babuschkin, A.
    Barboutis, A.
    Buchholz, C.
    Fischer, A.
    Jaroslawzew, S.
    Lehnert, J.
    Mentzel, H.
    Puls, J.
    Schoenstedt, A.
    Sintschuk, M.
    Stadelhoff, C.
    Tagbo, C.
    Scholze, F.
    EXTREME ULTRAVIOLET (EUV) LITHOGRAPHY X, 2019, 10957