High-accuracy detector calibration in the 3-1500 eV spectral range at the PTB radiometry laboratory

被引:7
|
作者
Scholze, F [1 ]
Henneken, H [1 ]
Kuschnerus, P [1 ]
Rabus, H [1 ]
Richter, M [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
来源
关键词
photodiodes; detector calibration; soft X-rays; primary detector standards;
D O I
10.1107/S0909049597014076
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
State-of-the-art detector calibration in the UV/VUV and soft Xray spectral ranges at the Physikalisch-Technische Bundesanstalt (PTB) is based on the primary detector standard SYRES, a cryogenic electrical substitution radiometer capable of measuring radiant power of a few mu W. At the PTB radiometry laboratory at the synchrotron radiation facility BESSY, two dedicated beamlines are operated, providing monochromatic radiation of high spectral purity, high radiant power and tunable photon energy in the 3-1500eV range. The spectral responsivity of detectors, e.g. photodiodes, can be measured with a relative uncertainty of about 1% by direct comparison with SYRES, as will be demonstrated for PtSi/Si and GaAsP/Au Schottky and silicon n-on-p photodiodes. The calibration of photon-counting detectors traceable to SYRES can by accomplished by exploiting the unique capability to scale the spectral photon flux over several orders of magnitude by changing the stored electron current. Calibrations of CCDs and photomultipliers are presented as examples.
引用
收藏
页码:866 / 868
页数:3
相关论文
共 50 条
  • [21] Detector-based calibration method for high-accuracy solar UV measurements
    Karha, P
    Visuri, R
    Leszczynski, K
    Manoochehri, F
    Jokela, K
    Ikonen, E
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1996, 64 (02) : 340 - 343
  • [22] DETECTOR CALIBRATION IN THE 10-60 NM SPECTRAL RANGE AT THE ELECTROTECHNICAL LABORATORY
    SAITO, T
    ONUKI, H
    JOURNAL OF OPTICS-NOUVELLE REVUE D OPTIQUE, 1993, 24 (01): : 23 - 30
  • [23] The upgraded PTB 600 m baseline: a high-accuracy reference for the calibration and the development of long distance measurement devices
    Pollinger, Florian
    Meyer, Tobias
    Beyer, Jens
    Doloca, Nicolae R.
    Schellin, Wolfgang
    Niemeier, Wolfgang
    Jokela, Jorma
    Hakli, Pasi
    Abou-Zeid, Ahmed
    Meiners-Hagen, Karl
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (09)
  • [24] High-accuracy calculations of the refractive indices of optical materials in a wide spectral range
    Shanghai Inst. Opt. Fine Mechanics, Academia Sinica, P.O. Box 800-216, Shanghai 201800, China
    Appl. Opt., 1 (158-160):
  • [25] High-accuracy calculations of the refractive indices of optical materials in a wide spectral range
    Jing, L
    Li, XS
    Yi, L
    APPLIED OPTICS, 1996, 35 (01): : 158 - 160
  • [26] COMPARISON OF THE NIST HIGH-ACCURACY CRYOGENIC RADIOMETER AND THE NIST SCALE OF DETECTOR SPECTRAL RESPONSE
    HOUSTON, JM
    CROMER, CL
    HARDIS, JE
    LARASON, TC
    METROLOGIA, 1993, 30 (04) : 285 - 290
  • [27] Fast and high-accuracy spectral measurements of LED by linear CCD sensor and software calibration
    Wang, DH
    Qian, H
    Yuan, X
    Advanced Materials and Devices for Sensing and Imaging II, 2005, 5633 : 578 - 584
  • [28] Research on high-accuracy in-flight spectral calibration of the solar backscattered ultraviolet spectroradiometer
    Li, Zhanfeng
    Wang, Shurong
    Huang, Yu
    Yu, Xiangyang
    Guangxue Xuebao/Acta Optica Sinica, 2013, 33 (02):
  • [29] Detector based calibration of solar UV radiometers in laboratory environments with high accuracy
    Durak, M
    San, SE
    Aslan, MH
    MEASUREMENT, 2005, 37 (03) : 213 - 217
  • [30] HIGH-ACCURACY CAMERA CALIBRATION FOR 3-D COMPUTER VISION
    NOMURA, Y
    SAGARA, M
    NARUSE, H
    IDE, A
    IECON 89, VOLS 1-4: POWER ELECTRONICS - SIGNAL-PROCESSING & SIGNAL CONTROL - FACTORY AUTOMATION, EMERGING TECHNOLOGIES, 1989, : 480 - 485