High-accuracy calibration of the HXDS flow proportional counter for AXAF at the PTB laboratory at BESSY

被引:12
|
作者
Auerhammer, JM [1 ]
Brandt, G [1 ]
Scholze, F [1 ]
Thomagel, R [1 ]
Ulm, G [1 ]
Wargelin, BJ [1 ]
McDermott, WC [1 ]
Norton, TJ [1 ]
Evans, IN [1 ]
Kellogg, EM [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
来源
关键词
proportional counters; detectors; calibration; x-rays; synchrotron radiation; primary detector standard;
D O I
10.1117/12.331242
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
The Smithsonian Astrophysical Observatory uses the HRMA X-ray Detection System (HXDS) to calibrate the High-Resolution Mirror Assembly (HRMA) of the Advanced X-ray Astrophysics Facility AXAF. Apart from two high-purity-germanium solid-state detectors (SSDs) with good energy resolution and very high efficiency at higher energies, the detection sq stem comprises seven now proportional counters (FPCs) and one microchannel-plate High-Speed Imager. For the lower energy range, the FPCs are more appropriate. They have been calibrated at the radiometry laboratory of the Physikalisch-Technische Bundesanstalt, using the electron storage ring BESSY. For the determination of the absolute quantum efficiency two methods have been applied. First, the detector response was measured in the lower energy range 0.1 keV to 1.7 keV at several discrete energies using monochromatized radiation. The absolute photon flux has been determined by Si n-on-p photodiodes, calibrated against a cryogenic electrical-substitution radiometer used as primary detector standard. The second method uses the undispersed synchrotron radiation emitted by a bending magnet of the primary source standard BESSY, which can be calculated very accurately. Combining both measurements the determination of the detection efficiency over the entire desired spectral range (0.1 keV to 10 keV) was possible with a typical relative uncertainty around 1% to 2% in the central energy range (0.2 keV to 1.7 keV).
引用
收藏
页码:19 / 29
页数:11
相关论文
共 50 条
  • [41] A NEW CAMERA CALIBRATION METHOD FOR HIGH-ACCURACY NONCONTACT METROLOGY
    CUMANI, A
    GUIDUCCI, A
    PATTERN RECOGNITION LETTERS, 1993, 14 (05) : 415 - 419
  • [42] PTB's enhanced stitching approach for the high-accuracy interferometric form error characterization of spheres
    Bartl, Guido
    Krystek, Michael
    Nicolaus, Arnold
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2014, 25 (06)
  • [43] HIGH-ACCURACY PREFORMED GRADIENT DISCONTINUOUS FLOW TITRIMETRY
    PETTY, JD
    PETTY, DA
    PEACHEY, RM
    SMITH, TK
    KRIEGER, BL
    TALANTA, 1994, 41 (03) : 359 - 365
  • [44] Meters: High-accuracy stormwater, CSO flow monitoring
    Anon
    Water and Wastes Digest, 2002, 42 (07):
  • [45] HIGH-ACCURACY RESTRICTING FLOW-DIVIDER VALVE
    SKRITSKI.VY
    RUSSIAN ENGINEERING JOURNAL, 1974, 54 (01): : 15 - 17
  • [46] Robot-mounted sensing and local calibration for high-accuracy manufacturing
    Dehghani, Mohammadreza
    McKenzie, Ryan A.
    Irani, Rishad A.
    Ahmadi, Mojtaba
    ROBOTICS AND COMPUTER-INTEGRATED MANUFACTURING, 2023, 79
  • [47] A High-accuracy Camera Calibration Method Based on Special Circular Target
    Wen, Guanzhijing
    Yang, Yilan
    Yang, Zeyuan
    Yue, Jin
    Yan, Sijie
    2022 INTERNATIONAL CONFERENCE ON INDUSTRIAL AUTOMATION, ROBOTICS AND CONTROL ENGINEERING, IARCE, 2022, : 24 - 28
  • [48] Development of an automatic calibration device for high-accuracy low temperature thermometers
    GuangMing Chen
    Xu Gao
    ShaoZhi Zhang
    Qi Chen
    LiMing Tang
    YuQi Lan
    Science China Technological Sciences, 2010, 53 : 2404 - 2407
  • [49] DeepRefiner: high-accuracy protein structure refinement by deep network calibration
    Shuvo, Md Hossain
    Gulfam, Muhammad
    Bhattacharya, Debswapna
    NUCLEIC ACIDS RESEARCH, 2021, 49 (W1) : W147 - W152
  • [50] A simple spectrogram model for high-accuracy spectral calibration of VIPA spectrometers
    Zhou, Hao
    Zhao, Weixiong
    Cui, Weihua
    Lv, Bingxuan
    Fang, Bo
    Yang, Nana
    Xiang, Guangfeng
    Zhang, Weijun
    Deng, Lunhua
    Chen, Weidong
    ANALYST, 2024, 149 (22) : 5455 - 5462