Resistive plate chamber neutron and gamma sensitivity measurement with a 252Cf source

被引:23
|
作者
Abbrescia, M
Altieri, S
Baratti, V
Barnabà, O
Belli, G
Bruno, G
Colaleo, A
DeVecchi, C
Guida, R
Iaselli, G
Imbres, E
Loddo, F
Maggi, M
Marangelli, B
Musitelli, G
Nardò, R
Natali, S
Nuzzo, S
Pugliese, G
Ranieri, A
Ratti, S
Riccardi, C
Romano, F
Torre, P
Vicini, A
Vitulo, P
Volpe, F
机构
[1] Univ Pavia, Dipartimento Fis Nucl & Teor, I-27100 Pavia, Italy
[2] Ist Nazl Fis Nucl, Sez Pavia, I-27100 Pavia, Italy
[3] Univ Bari, Dipartimento Interateneo Fis, I-70126 Bari, Italy
[4] Ist Nazl Fis Nucl, Sez Bari, I-70126 Bari, Italy
关键词
Resistive Plate Chamber; gamma sensitivity; neutron sensitivity; Compact Muon Solenoid;
D O I
10.1016/S0168-9002(03)01378-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A bakelite double gap Resistive Plate Chamber (R-PC), operating in avalanche mode, has been exposed to the radiation emitted from a Cf-252 source to measure its neutron and gamma sensitivity. One of the two gaps underwent the traditional electrodes surface coating with linseed oil. RPC signals were triggered by fission events detected using BaF2 scintillators. A Monte Carlo code, inside the GEANT 3.21 framework with MICAP interface, has been used to identify the gamma and neutron contributions to the total number of collected RPC signals. A neutron sensitivity of (0.63 +/- 0.02) x 10(-3) (average energy 2 MeV) and a gamma sensitivity of (14.0 +/- 0.5) x 10(-3) (average energy 1.5 MeV) have been measured in double gap mode. Measurements done in single gap mode have shown that both neutron and gamma sensitivity are independent of the oiling treatment. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:101 / 109
页数:9
相关论文
共 50 条
  • [41] Measurement of very high threshold reactions using 252Cf source
    Schulc, Martin
    Kostal, Michal
    Simon, Jan
    Novak, Evzen
    Juricek, Vlastimil
    Marecek, Martin
    APPLIED RADIATION AND ISOTOPES, 2020, 166
  • [42] GAMMA RAYS FOR SPONTANEOUS FISSION OF 252CF
    SKARSVAG, K
    FRASER, JS
    MILTON, JCD
    PHYSICA NORVEGICA, 1967, 2 (02): : 133 - &
  • [43] Shielding design studies for a neutron irradiator system based on a 252Cf source
    da Silva, AX
    Crispim, VR
    RADIATION PROTECTION DOSIMETRY, 2001, 95 (04) : 333 - 338
  • [44] New evidence of an intense scission neutron source in the 252Cf spontaneous fission
    Kornilov, NV
    Kagalenko, AB
    Poupko, SV
    Androsenko, PA
    Hambsch, FJ
    NUCLEAR PHYSICS A, 2001, 686 : 187 - 203
  • [45] Determining 252Cf source strength by absolute passive neutron correlation counting
    Croft, S.
    Henzlova, D.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 714 : 5 - 12
  • [46] Calibration of Spherical Neutron Measuring Devices with a 252Cf Source in the Neutron Calibration Room of the KAERI
    Jun, Sun-Mee
    Kim, Bong-Hwan
    Kim, Jang-Lyul
    Lee, Jai Ki
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 286 - 289
  • [47] Shielding cask for a 252Cf ion source
    Baker, SI
    Moore, EF
    Pardo, RC
    Savard, G
    HEALTH PHYSICS, 2005, 89 (01): : S34 - S34
  • [48] Measurement of dose enhancement by neutron capture of boron in 252Cf interstitial brachytherapy
    Abd El-Hafez, AI
    Eissa, HM
    Eman, SA
    Fadel, MA
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 441 - 444
  • [49] DETERMINATION OF URANIUM IN SOLUTIONS BY THE NEUTRON ACTIVATION ANALYSIS METHOD WITH 252Cf RADIONUCLIDE NEUTRON SOURCE
    Ivannikov, Sergei I.
    Markin, Nikita S.
    Zheleznov, Veniamin V.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2021, 36 (01): : 12 - 17
  • [50] Material recognition by using 252Cf source
    Hao, Xin
    Zhu, Li-Hua
    Stevanato, L.
    Fabris, D.
    Lunardon, M.
    Moretto, S.
    Nebbia, G.
    Pesente, S.
    Viesti, G.
    Sajo-Bohus, L.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2011, 45 (04): : 479 - 482