Resistive plate chamber neutron and gamma sensitivity measurement with a 252Cf source

被引:23
|
作者
Abbrescia, M
Altieri, S
Baratti, V
Barnabà, O
Belli, G
Bruno, G
Colaleo, A
DeVecchi, C
Guida, R
Iaselli, G
Imbres, E
Loddo, F
Maggi, M
Marangelli, B
Musitelli, G
Nardò, R
Natali, S
Nuzzo, S
Pugliese, G
Ranieri, A
Ratti, S
Riccardi, C
Romano, F
Torre, P
Vicini, A
Vitulo, P
Volpe, F
机构
[1] Univ Pavia, Dipartimento Fis Nucl & Teor, I-27100 Pavia, Italy
[2] Ist Nazl Fis Nucl, Sez Pavia, I-27100 Pavia, Italy
[3] Univ Bari, Dipartimento Interateneo Fis, I-70126 Bari, Italy
[4] Ist Nazl Fis Nucl, Sez Bari, I-70126 Bari, Italy
关键词
Resistive Plate Chamber; gamma sensitivity; neutron sensitivity; Compact Muon Solenoid;
D O I
10.1016/S0168-9002(03)01378-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A bakelite double gap Resistive Plate Chamber (R-PC), operating in avalanche mode, has been exposed to the radiation emitted from a Cf-252 source to measure its neutron and gamma sensitivity. One of the two gaps underwent the traditional electrodes surface coating with linseed oil. RPC signals were triggered by fission events detected using BaF2 scintillators. A Monte Carlo code, inside the GEANT 3.21 framework with MICAP interface, has been used to identify the gamma and neutron contributions to the total number of collected RPC signals. A neutron sensitivity of (0.63 +/- 0.02) x 10(-3) (average energy 2 MeV) and a gamma sensitivity of (14.0 +/- 0.5) x 10(-3) (average energy 1.5 MeV) have been measured in double gap mode. Measurements done in single gap mode have shown that both neutron and gamma sensitivity are independent of the oiling treatment. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:101 / 109
页数:9
相关论文
共 50 条
  • [21] Water-extended polyester neutron shield for a 252Cf neutron source
    Vega-Carrillo, H. R.
    Manzanares-Acuna, E.
    Hernandez-Davila, V. M.
    Gallego, E.
    Lorente, A.
    Donaire, I.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 269 - 273
  • [22] Absolute neutron emission rate measurement of a 252Cf source by the manganous sulfate bath method
    Hwang, Sun-Tae
    Lee, Kun Jai
    Nuclear instruments and methods in physics research, 1988, 273 (01): : 381 - 388
  • [23] Sensitivity of neutron observables to the model input in simulations of 252Cf(sf)
    Randrup, J.
    Talou, P.
    Vogt, R.
    PHYSICAL REVIEW C, 2019, 99 (05)
  • [24] Development of 252Cf fast fission chamber
    Li, J.S.
    Zhang, Y.
    Jin, Y.
    Li, R.L.
    Hedianzixue Yu Tance Jishu/Nuclear Electronics & Detection Technology, 2001, 21 (04):
  • [25] Application of 252Cf neutron source for precise nuclear data experiments
    Schulc, Martin
    Kostal, Michal
    Novak, Evzen
    Kubin, Rostislav
    Simon, Jan
    APPLIED RADIATION AND ISOTOPES, 2019, 151 : 187 - 195
  • [26] DOSIMETRY OF AN IMPLANTABLE 252CF SOURCE
    OLIVER, GD
    WRIGHT, CN
    RADIOLOGY, 1969, 92 (01) : 143 - +
  • [27] Design of a setup for 252Cf neutron source for storage and analysis purpose
    Hei Daqian
    Zhuang Haocheng
    Jia Wenbao
    Cheng Can
    Jiang Zhou
    Wang Hongtao
    Chen Da
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 386 : 1 - 3
  • [28] ANISOTROPY FACTORS FOR A 252Cf SOURCE
    Veinot, K. G.
    Bogard, J. S.
    NUCLEAR TECHNOLOGY, 2009, 168 (02) : 364 - 368
  • [29] Measurement of fast neutron, gamma, and thermal neutron dose around a cf-252 source
    Wanwilairat, S
    Vilaithong, T
    Lorvidhaya, V
    Schmidt, R
    Hoffmann, W
    FRONTIERS IN NEUTRON CAPTURE THERAPY, VOLS 1 AND 2, 2001, : 539 - 545
  • [30] Graphite moderated 252Cf source
    Sajo-Bohus, Laszlo
    Barros, Haydn
    Greaves, Eduardo D.
    Rene Vega-Carrillo, Hector
    APPLIED RADIATION AND ISOTOPES, 2015, 100 : 108 - 112