Resistive plate chamber neutron and gamma sensitivity measurement with a 252Cf source

被引:23
|
作者
Abbrescia, M
Altieri, S
Baratti, V
Barnabà, O
Belli, G
Bruno, G
Colaleo, A
DeVecchi, C
Guida, R
Iaselli, G
Imbres, E
Loddo, F
Maggi, M
Marangelli, B
Musitelli, G
Nardò, R
Natali, S
Nuzzo, S
Pugliese, G
Ranieri, A
Ratti, S
Riccardi, C
Romano, F
Torre, P
Vicini, A
Vitulo, P
Volpe, F
机构
[1] Univ Pavia, Dipartimento Fis Nucl & Teor, I-27100 Pavia, Italy
[2] Ist Nazl Fis Nucl, Sez Pavia, I-27100 Pavia, Italy
[3] Univ Bari, Dipartimento Interateneo Fis, I-70126 Bari, Italy
[4] Ist Nazl Fis Nucl, Sez Bari, I-70126 Bari, Italy
关键词
Resistive Plate Chamber; gamma sensitivity; neutron sensitivity; Compact Muon Solenoid;
D O I
10.1016/S0168-9002(03)01378-0
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A bakelite double gap Resistive Plate Chamber (R-PC), operating in avalanche mode, has been exposed to the radiation emitted from a Cf-252 source to measure its neutron and gamma sensitivity. One of the two gaps underwent the traditional electrodes surface coating with linseed oil. RPC signals were triggered by fission events detected using BaF2 scintillators. A Monte Carlo code, inside the GEANT 3.21 framework with MICAP interface, has been used to identify the gamma and neutron contributions to the total number of collected RPC signals. A neutron sensitivity of (0.63 +/- 0.02) x 10(-3) (average energy 2 MeV) and a gamma sensitivity of (14.0 +/- 0.5) x 10(-3) (average energy 1.5 MeV) have been measured in double gap mode. Measurements done in single gap mode have shown that both neutron and gamma sensitivity are independent of the oiling treatment. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:101 / 109
页数:9
相关论文
共 50 条
  • [1] TOF spectrum measurement of 252Cf source fission neutron and gamma ray
    College of Communication Engineering, Chongqing University, Chongqing 400044, China
    不详
    Qiangjiguang Yu Lizishu, 2009, 11 (1719-1723):
  • [2] MEASUREMENT OF THE 250CF COMPONENT IN A 252CF NEUTRON SOURCE AT KRISS
    Kim, Jungho
    Park, Hyeonseo
    Choi, Kil-Oung
    RADIATION PROTECTION DOSIMETRY, 2014, 161 (1-4) : 171 - 175
  • [3] ADVANTAGES AND APPLICATIONS OF 252CF AS A NEUTRON SOURCE
    REINIG, WC
    NUCLEAR APPLICATIONS, 1968, 5 (01): : 24 - &
  • [4] Fast neutron spectra measurement in a copper using a 252Cf standard neutron source
    Schulc, Martin
    Kostal, Michal
    Matej, Zdenek
    Czakoj, Tomas
    Novak, Evzen
    RADIATION PHYSICS AND CHEMISTRY, 2022, 192
  • [5] DESIGN DATA FOR 252CF NEUTRON SOURCE EXPERIMENTS
    NICHOLS, JP
    NUCLEAR APPLICATIONS, 1968, 4 (06): : 382 - &
  • [6] Neutron dosimetry for a general 252Cf brachytherapy source
    Rivard, MJ
    MEDICAL PHYSICS, 2000, 27 (12) : 2803 - 2815
  • [7] NEUTRON RADIOGRAPHY WITH 252CF
    CASON, JL
    SHAW, CB
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1969, 12 (02): : 464 - &
  • [8] Neutron and gamma ray doses from a 252Cf brachytherapy source in a water phantom
    Al-Saihati, Ibahim
    Naqvi, A. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2013, 296 (02) : 963 - 966
  • [9] Neutron and gamma ray doses from a 252Cf brachytherapy source in a water phantom
    Ibahim Al-Saihati
    A. A. Naqvi
    Journal of Radioanalytical and Nuclear Chemistry, 2013, 296 : 963 - 966
  • [10] Study of the neutron flux in a model for a 252Cf cold neutron source
    Robinson, L
    Johnson, E
    Zhao, L
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 238 (1-2) : 25 - 28