Effect of geometric variations on image characteristics in digital tomosynthesis

被引:0
|
作者
Lee, Seungwan [1 ,2 ]
Kim, Burnyoung [1 ]
Yim, Dobin [2 ]
Lee, Youngjin [3 ]
机构
[1] Konyang Univ, Dept Med Sci, Daejeon, South Korea
[2] Konyang Univ, Dept Radiol Sci, Coll Med Sci, Daejeon, South Korea
[3] Gachon Univ, Dept Radiol Sci, Coll Hlth Sci, Incheon, South Korea
基金
新加坡国家研究基金会;
关键词
Digital tomosynthesis; geometric variation; X-ray source scan trajectories; scan angles; BREAST TOMOSYNTHESIS;
D O I
10.1117/12.2543148
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Digital tomosynthesis (DTS) has been used in diagnosis and radiation therapy due to its performance and benefits. DTS is able to provide 3D images with good depth resolution comparing to conventional radiography and reduce radiation dose comparing to computed tomography (CT). However, DTS scans with limited scan angles and a few projections lead to the insufficiency in data acquisition. Such a drawback causes the alteration of image characteristics and the distortion of image quality in DTS imaging. These issues can be magnified by the geometric variations of the DTS systems and the imaging strategies. In this study, the effect of geometric variations on image characteristics was evaluated by the DTS systems simulated with various X-ray source scan trajectories and angles. The DTS images were analyzed in terms of noise property, contrast-to-noise ratio (CNR), and spatial resolution. The results showed that the quality of DTS images was highly dependent on X-ray source scan trajectories and angles, and the characteristics of DTS images varied according to their acquisition geometries. Therefore, the geometries and strategies for DTS imaging should be appropriately determined for optimizing their systems and applications.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Digital Tomosynthesis Image Quality in a Co-60 Treatment Beam
    Marsh, M.
    Schreiner, L. J.
    Kerr, A.
    MEDICAL PHYSICS, 2012, 39 (07) : 4633 - 4633
  • [42] Effect of source blur on digital breast tomosynthesis reconstruction
    Zheng, Jiabei
    Fessler, Jeffrey A.
    Chan, Heang-Ping
    MEDICAL PHYSICS, 2019, 46 (12) : 5572 - 5592
  • [43] 3D Medical Image Reconstruction on Digital Breast Tomosynthesis
    Duarte, Isabel Catarina
    Janela, Filipe
    Caldeira, Liliana
    Soares, Filipe
    Silva, Jose Silvestre
    2012 IEEE 2ND PORTUGUESE MEETING IN BIOENGINEERING (ENBENG), 2012,
  • [44] Effects of Beam Modulation Schemes on Image Quality in Digital Tomosynthesis System
    Kim, D.
    Lee, D.
    Lee, H.
    Kim, H.
    Chao, Z.
    Lee, M.
    Kim, H.
    MEDICAL PHYSICS, 2018, 45 (06) : E609 - E609
  • [45] Improving depth resolution in digital breast tomosynthesis by iterative image reconstruction
    Roth, Erin G.
    Kraemer, David N.
    Sidky, Emil Y.
    Reiser, Ingrid S.
    Pan, Xiaochun
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [46] Use of the Hotelling observer to optimize image reconstruction in digital breast tomosynthesis
    Sanchez, Adrian A.
    Sidky, Emil Y.
    Pan, Xiaochuan
    JOURNAL OF MEDICAL IMAGING, 2016, 3 (01)
  • [47] Multiscale bilateral filtering for improving image quality in digital breast tomosynthesis
    Lu, Yao
    Chan, Heang-Ping
    Wei, Jun
    Hadjiiski, Lubomir M.
    Samala, Ravi K.
    MEDICAL PHYSICS, 2015, 42 (01) : 182 - 195
  • [48] Statistical iterative reconstruction to improve image quality for digital breast tomosynthesis
    Xu, Shiyu
    Lu, Jianping
    Zhou, Otto
    Chen, Ying
    MEDICAL PHYSICS, 2015, 42 (09) : 5377 - 5390
  • [49] RELATIONSHIP BETWEEN RADIATION DOSE AND IMAGE QUALITY IN DIGITAL BREAST TOMOSYNTHESIS
    Alakhras, Maram M.
    Mello-Thoms, Claudia
    Bourne, Roger
    Rickard, Mary
    Diffey, Jennifer
    Brennan, Patrick C.
    RADIATION PROTECTION DOSIMETRY, 2017, 173 (04) : 351 - 360
  • [50] Assessing and Improving Cobalt-60 Digital Tomosynthesis Image Quality
    Marsh, Matthew B.
    Schreiner, L. John
    Kerr, Andrew T.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033