Extensive research for establishing the emissions of heavy metals from coal-fired power stations is performed in the Netherlands for the past 25 years. In the Netherlands coal is fired from all over the world. This means that the emissions are established for coal of various origins. In the eighties, the emissions of installations equipped with ESPs (electrostatic precipitators) were measured. In the nineties, the influence of wet FGD (flue gas desulphurisation) on the emissions was studied. The effect of co-combustion of biomass and other secondary fuels is the main item for the last 10 years. Fifty-five elements were measured in the solid state and eight elements in the gaseous phase. It appeared that at low particulate concentration the influence of calcium containing evaporated water droplets downstream the wet FGD on the emissions of heavy metals is bigger than the composition of the coal. Also it appeared that at modern coal-fired power stations the emissions are hardly influenced by co-combustion of biomass. All the results are used for modelling, resulting in the KEMA TRACE MODEL (R), by which the emissions can be predicted. The established emission factors are for most elements in good agreement with literature values for comparable modern installations. Persistence organic pollutants (POPs) that were detected in the flue gases of coal-fired power stations are polycyclic aromatic hydrocarbons (PAH) and dioxins/furans. Measurements during full coal-firing and during co-firing of biomass have indicated that these emissions are negligible. (C)2007 Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:9262 / 9272
页数:11
相关论文
共 50 条
  • [31] BERYLLIUM EMISSIONS FROM A COAL-FIRED POWER-PLANT
    GLADNEY, ES
    OWENS, JW
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-ENVIRONMENTAL SCIENCE AND ENGINEERING & TOXIC AND HAZARDOUS SUBSTANCE CONTROL, 1976, 11 (4-5): : 297 - 311
  • [32] Characterization of mercury emissions from a coal-fired power plant
    Guo, Xin
    Zheng, Chu-Guang
    Xu, Minghou
    ENERGY & FUELS, 2007, 21 (02) : 898 - 902
  • [33] Characterization of arsenic emissions from a coal-fired power plant
    Guo, X
    Zheng, CG
    Xu, MH
    ENERGY & FUELS, 2004, 18 (06) : 1822 - 1826
  • [34] Emissions of sulfur trioxide from coal-fired power plants
    Srivastava, RK
    Miller, CA
    Erickson, C
    Jambhekar, R
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2004, 54 (06) : 750 - 762
  • [35] COAL-FIRED POWER-STATIONS UNDER CONSTRUCTION
    MULLER, K
    BRENNSTOFF-WARME-KRAFT, 1985, 37 (03): : 85 - 86
  • [36] Operational experience with large coal-fired power stations
    Mandle, K.T.
    Power Engineering Journal, 1988, 2 (05): : 248 - 252
  • [37] TENDENCIES IN THE DEVELOPMENT OF COAL-FIRED POWER-STATIONS
    LEZUO, A
    RIEDLE, K
    WITTCHOW, E
    BRENNSTOFF-WARME-KRAFT, 1989, 41 (1-2): : 13 - 22
  • [38] EMISSION FACTOR OF MERCURY FROM COAL-FIRED POWER-STATIONS
    MNISZEK, W
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 1994, 33 (02) : 161 - 170
  • [39] Effects of selective mining on coal-fired power stations
    Vogt, W
    Strunk, S
    MINING SCIENCE AND TECHNOLOGY, 1996, : 29 - 36
  • [40] Reducing land requirement for coal-fired power stations
    Hari, A.S. (harias@lntecc.com), 1600, Vogel Verlag und Druck GmbH and Co. KG (34):