Reply to "Comment on "Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning' [Med. Phys. 43(6), 2845-2854 (2016)]"

被引:0
|
作者
Penfold, Scott N. [1 ,2 ]
Zhu, Jiahua [2 ]
机构
[1] Royal Adelaide Hosp, Dept Med Phys, Adelaide, SA 5000, Australia
[2] Univ Adelaide, Dept Phys, Adelaide, SA 5005, Australia
关键词
D O I
10.1002/mp.12491
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:5537 / 5538
页数:2
相关论文
共 13 条
  • [1] Comment on: Dosimetric comparison of stopping-power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning [Med. Phys. 43(6), 2845-2854 (2016)]
    Wohlfahrt, Patrick
    Moehler, Christian
    Greilich, Steffen
    Richter, Christian
    MEDICAL PHYSICS, 2017, 44 (10) : 5533 - 5536
  • [2] Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning
    Zhu, Jiahua
    Penfold, Scott N.
    MEDICAL PHYSICS, 2016, 43 (06) : 2845 - 2854
  • [3] Dosimetric Comparison between Single-energy Computed Tomography and Dual-energy Computed Tomography Relative to Stopping Power Estimation in Proton Therapy
    Chirdchid, Thamonwan
    Ruangchan, Sirinya
    Sanghangthum, Taweap
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (03) : 292 - 297
  • [4] Reply to: "Comment on: Dual-energy CT quantitative imaging: A comparison study between twin-beam and dual-source CT scanners [Med. Phys. 44(1), 171-179 (2017)]"
    Almeida, Isabel P.
    Landry, Guillaume
    van Elmpt, Wouter
    Parodi, Katia
    Verhaegen, Frank
    MEDICAL PHYSICS, 2018, 45 (08) : 3997 - 3998
  • [5] Comparison of single and dual-energy CT based proton treatment planning for neuro patients
    van der Maas, T.
    Taasti, V. T.
    Rinaldi, I.
    Verhaegen, F.
    Fonseca, G.
    van Elmpt, W.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1282 - S1283
  • [6] Revisiting the single-energy CT calibration for proton therapy treatment planning: a critical look at the stoichiometric method
    Goma, Carles
    Almeida, Isabel P.
    Verhaegen, Frank
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (23):
  • [7] Accuracy of proton stopping power estimation of silicone breast implants with single and dual-energy CT calibration techniques
    Chacko, Michael S.
    Grewal, Hardev S.
    Wu, Dee
    Sonnad, Jagadeesh R.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (09): : 159 - 170
  • [8] Comment on: Dual-energy CT quantitative imaging: A comparison study between twin-beam and dual-source CT scanners [Med. Phys. 44(1), 171-179 (2017)]
    Saito, Masatoshi
    MEDICAL PHYSICS, 2018, 45 (08) : 3996 - 3996
  • [9] A comparison of relative proton stopping power measurements across patient size using dual- and single-energy CT
    Michalak, Gregory
    Taasti, Vicki
    Krauss, Bernhard
    Deisher, Amanda
    Halaweish, Ahmed
    McCollough, Cynthia
    ACTA ONCOLOGICA, 2017, 56 (11) : 1465 - 1471
  • [10] Comparison of single and dual energy CT for stopping power determination in proton therapy of head and neck cancer
    Taasti, Vicki Trier
    Muren, Ludvig Paul
    Jensen, Kenneth
    Petersen, Jorgen Breede Baltzer
    Thygesen, Jesper
    Tietze, Anna
    Grau, Cai
    Hansen, David Christoffer
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2018, 6 : 14 - 19