Characterisation of the gas-liquid mass transfer in shaking bioreactors

被引:186
|
作者
Maier, U [1 ]
Büchs, J [1 ]
机构
[1] Aachen Tech Univ, Dept Biochem Engn, Sammelbau Biol, D-52074 Aachen, Germany
关键词
shaking bioreactors; oxygen transfer; screening; process development;
D O I
10.1016/S1369-703X(00)00107-8
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The maximum gas-liquid mass transfer capacity of 250 ml shaking flasks on orbital shaking machines has been experimentally investigated using the sulphite oxidation method under variation of the shaking frequency, shaking diameter, filling volume and viscosity of the medium. The distribution of the liquid within the flask has been modelled by the intersection between the rotational hyperboloid of the liquid and the inner wall of the shaking flask. This model allows for thr calculation of the specific exchange area (a), the mass transfer coefficient (k(L)) and the maximum oxygen transfer capacity (OTRmax) for given operating conditions and requires no fitting parameters. The model agrees well with the experimental results. It was furthermore shown that the liquid film on the flask wall contributes significantly to the specific mass transfer area (a) and to the oxygen transfer rate (OTR). (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 50 条
  • [41] MASS TRANSFER IN MECHANICALLY AGITATED GAS-LIQUID CONTACTORS
    MEHTA, VD
    SHARMA, MM
    CHEMICAL ENGINEERING SCIENCE, 1971, 26 (03) : 461 - &
  • [42] Gas-liquid mass transfer studies in sonochemical reactors
    Kumar, A
    Gogate, PR
    Pandit, AB
    Delmas, H
    Wilhelm, AM
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (08) : 1812 - 1819
  • [43] Gas-liquid mass transfer - Influence of sparger location
    Sardeing, R
    Aubin, J
    Poux, M
    Xuereb, C
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2004, 82 (A9): : 1161 - 1168
  • [44] Enhancing gas-liquid volumetric mass transfer coefficient
    Ho, Dongil
    Kim, Kwangmin
    Earmme, Taeshik
    Kim, Choongik
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2020, 87 : 1 - 17
  • [45] Characteristics of gas-liquid mass transfer for EGSTAR agitator
    Ohishi, T
    Hiraoka, S
    Kato, Y
    Tada, Y
    Ito, Y
    Yamaguchi, T
    KAGAKU KOGAKU RONBUNSHU, 1998, 24 (06) : 977 - 979
  • [46] Intensification of Mass Transfer in a Gas-Liquid Apparatus with a Mixer
    Voinov, N. A.
    Frolov, A. S.
    Bogatkova, A. V.
    Zhukova, O. P.
    THEORETICAL FOUNDATIONS OF CHEMICAL ENGINEERING, 2024, 58 (04) : 1166 - 1175
  • [47] GAS-LIQUID MASS-TRANSFER IN MICROBIOLOGICAL REACTORS
    ANDREW, SPS
    TRANSACTIONS OF THE INSTITUTION OF CHEMICAL ENGINEERS, 1982, 60 (01): : 3 - 13
  • [48] GAS-LIQUID MASS TRANSFER IN COCURRENT FROTH FLOW
    HEUSS, JM
    KING, CJ
    WILKE, CR
    AICHE JOURNAL, 1965, 11 (05) : 866 - &
  • [49] Recent development of enhancement of gas-liquid mass transfer
    Cheng, H
    Zhou, M
    Yu, GC
    PROGRESS IN CHEMISTRY, 2001, 13 (04) : 315 - 322
  • [50] EFFECT OF CONCENTRATION ON GAS-LIQUID MASS TRANSFER COEFFICIENT
    GIBBS, RK
    HIMMELBLAU, DM
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1963, 2 (01): : 55 - &