Characterisation of the gas-liquid mass transfer in shaking bioreactors

被引:186
|
作者
Maier, U [1 ]
Büchs, J [1 ]
机构
[1] Aachen Tech Univ, Dept Biochem Engn, Sammelbau Biol, D-52074 Aachen, Germany
关键词
shaking bioreactors; oxygen transfer; screening; process development;
D O I
10.1016/S1369-703X(00)00107-8
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The maximum gas-liquid mass transfer capacity of 250 ml shaking flasks on orbital shaking machines has been experimentally investigated using the sulphite oxidation method under variation of the shaking frequency, shaking diameter, filling volume and viscosity of the medium. The distribution of the liquid within the flask has been modelled by the intersection between the rotational hyperboloid of the liquid and the inner wall of the shaking flask. This model allows for thr calculation of the specific exchange area (a), the mass transfer coefficient (k(L)) and the maximum oxygen transfer capacity (OTRmax) for given operating conditions and requires no fitting parameters. The model agrees well with the experimental results. It was furthermore shown that the liquid film on the flask wall contributes significantly to the specific mass transfer area (a) and to the oxygen transfer rate (OTR). (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 50 条
  • [21] Mass transfer in gas-liquid flow in microchannels
    Yue, Jun
    Chen, Guangwen
    Yuan, Quan
    Luo, Ling'ai
    le Gall, Hervé
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2006, 57 (06): : 1296 - 1303
  • [22] MASS TRANSFER IN GAS-LIQUID CONTACTING SYSTEMS
    SIDEMAN, S
    HORTACSU, O
    FULTON, JW
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1966, 58 (07): : 32 - &
  • [23] MASS TRANSFER GAS-LIQUID IN COLUMN OF AERATION
    Salla, Marcio Ricardo
    Schulz, Harry Edmar
    ENGENHARIA SANITARIA E AMBIENTAL, 2008, 13 (02) : 189 - 197
  • [24] Mixing condition and solid-liquid and gas-liquid mass transfer in a shaking vessel with figure-eight motion
    Kato, Y
    Tada, Y
    Watanabe, S
    Nagatsu, Y
    Iwata, S
    Lee, YS
    Koh, ST
    KAGAKU KOGAKU RONBUNSHU, 2005, 31 (06) : 394 - 398
  • [25] Mass transfer resistance of sterile plugs in shaking bioreactors
    Mrotzek, C
    Anderlei, T
    Henzler, HJ
    Büchs, J
    BIOCHEMICAL ENGINEERING JOURNAL, 2001, 7 (02) : 107 - 112
  • [26] Gas-liquid mass transfer in vessels stirred with multiple impellers .1. Gas-liquid mass transfer characteristics in individual stages
    Linek, V
    Moucha, T
    Sinkule, J
    CHEMICAL ENGINEERING SCIENCE, 1996, 51 (12) : 3203 - 3212
  • [27] Gas-liquid and liquid-liquid mass transfer in microstructured reactors
    Kashid, Madhvanand N.
    Renken, Albert
    Kiwi-Minsker, Lioubov
    CHEMICAL ENGINEERING SCIENCE, 2011, 66 (17) : 3876 - 3897
  • [28] GAS-LIQUID SLUG FLOW IN MEMBRANE BIOREACTORS
    SMITH, WJ
    SALMON, PM
    ROBERTSON, CR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1988, 196 : 44 - MBTD
  • [29] MASS TRANSFER IN AGITATED GAS-LIQUID ABSORBERS - INDE
    ROBINSON, CW
    WILKE, CR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1970, (FEB): : 34 - &
  • [30] Mass Transfer Thermodynamics through a Gas-Liquid Interface
    Broderick, Alicia
    Rocha, M. Alejandra
    Khalifa, Yehia
    Shiflett, Mark B.
    Newberg, John T.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2019, 123 (11): : 2576 - 2584