Spectrophotometric simultaneous determination of manganese(II) and iron(II) in pharmaceutical by orthogonal signal correction-partial least squares

被引:17
|
作者
Goodarzi, Mohammad [1 ]
Goodarzi, Tahmine
Ghasemi, Nahid
机构
[1] Azad Univ Arak, Dept Chem, Fac Sci, Arak, Iran
[2] Azad Univ Arak, Yong Res Club, Arak, Iran
关键词
PRINCIPAL COMPONENT REGRESSION; NEAR-INFRARED SPECTRA; MULTIVARIATE REGRESSION; CALIBRATION METHODS; MICELLAR MEDIA; BASIS-SETS; PLS; NICKEL; COBALT; COPPER;
D O I
10.1002/adic.200790016
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The simultaneous determination of manganese(II) and iron(II) mixtures by using spectrophotometric methods is a difficult problem in analytical chemistry, due to spectral interferences. By multivariate calibration methods, such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used to remove the information unrelated to the target variables based on constrained principal component analysis. OSC is a suitable preprocessing method for partial least squares calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 450-600 nm range for 21 different mixtures of manganese(II) and iron(II). Calibration matrices were containing 0.05-1.2 and 0.1-2.3 mu g mL(-1) Mn(II) and Fc(II), respectively. The RMSEP for manganese(II) and iron(II) with OSC and without OSC were 0.0316, 0.0291, and 0.0907, 0.115, respectively. This procedure allows the simultaneous determination of manganese(II) and iron(II) in synthetic and real matrix samples with good reliability of the determination.
引用
收藏
页码:303 / 312
页数:10
相关论文
共 50 条
  • [41] Simultaneous spectrophotometric determination of Sn(II) and Sn(IV) by mean centering of ratio kinetic profiles and partial least squares methods
    Madrakian, Tayyebeh
    Afkhami, Abbas
    Moein, Roshanak
    Bahram, Morteza
    TALANTA, 2007, 72 (05) : 1847 - 1852
  • [42] Simultaneous spectrophotometric determination of Co (II) and Co (III) in acidic medium with partial least squares regression and artificial neural networks
    Yasin, Nausheen
    Naqvi, Syed Mumtaz Danish
    Akhter, Syed Mamnoon
    HELIYON, 2024, 10 (04)
  • [43] Partial Least Squares Method for Simultaneous Spectrophotometric Determination of Four Food Pigments
    Dong, Xiongzi
    Wang, Liping
    Tian, Yan
    Si, Shengzhu
    ASIAN JOURNAL OF CHEMISTRY, 2010, 22 (07) : 5759 - 5765
  • [44] Simultaneous spectrophotometric determination of four metals by the kernel partial least squares method
    Gao, L
    Ren, SX
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1999, 45 (1-2) : 87 - 93
  • [45] Simultaneous spectrophotometric determination of atrazine and dicamba in water by Partial Least Squares Regression
    Amador-Hernández, J
    Valázquez-Manzanares, M
    Gutiérrez-Ortiz, MD
    Hernández-Carlos, B
    Peral-Torres, M
    López-De-Alba, PL
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2005, 50 (02): : 461 - 464
  • [46] Simultaneous Spectrophotometric Determination of Piroxicam, Naproxen, Diclofenac Sodium and Mefenamic Acid in Pharmaceutical Formulations by Partial Least Squares Method
    Mahmood, Ruaa M.
    Darweesh, Samar A.
    Alassaf, Nahla A.
    Al-Khalisy, Rokayia S.
    METHODS AND OBJECTS OF CHEMICAL ANALYSIS, 2024, 19 (02): : 101 - 110
  • [47] Simultaneous spectrophotometric determination of iron, titanium, and aluminum by partial least-squares calibration method in micellar medium
    Safavi, A
    Mirzaee, M
    Abdollahi, H
    ANALYTICAL LETTERS, 2003, 36 (03) : 699 - 712
  • [48] Flow-injection chemiluminescence simultaneous determination of cobalt(II) and copper(II) using partial least squares calibration
    Li, BX
    Wang, DM
    Lv, HG
    Zhang, ZJ
    TALANTA, 2006, 69 (01) : 160 - 165
  • [49] SIMULTANEOUS SPECTROPHOTOMETRIC DETERMINATION OF IRON(III) AND COPPER(II)
    PETHO, G
    SZASZ, G
    MAGYAR KEMIAI FOLYOIRAT, 1986, 92 (08): : 380 - 383
  • [50] USE OF MANGANESE(III) FOR SPECTROPHOTOMETRIC DETERMINATION OF FERROCYANIDE, TIN(II), AND IRON(II)
    MALIK, WU
    AJMAL, M
    ANALYTICAL CHEMISTRY, 1962, 34 (02) : 207 - &