Flow-injection chemiluminescence simultaneous determination of cobalt(II) and copper(II) using partial least squares calibration

被引:60
|
作者
Li, BX [1 ]
Wang, DM [1 ]
Lv, HG [1 ]
Zhang, ZJ [1 ]
机构
[1] Shaanxi Normal Univ, Sch Chem & Mat Sci, Dept Chem, Xian 710062, Peoples R China
基金
中国国家自然科学基金;
关键词
flow-injection; chemiluminescence; partial least squares; simultaneous determination; Co2+ and Cu2+;
D O I
10.1016/j.talanta.2005.09.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection chemiluminescence (CL) system is proposed for simultaneous determination of Co2+ and Cu2+ using partial least squares (PLS) calibration. This method is based on the fact that both Co2+ and Cu2+ catalyse the CL reaction of luminol-H2O2, and that their kinetic characteristics of Co2+ and Cu2+ are significantly different in the luminol-H2O2 system. The CL intensity was measured and recorder at different reaction times of luminol-H2O2-Co2+-Cu2+, and the obtained data were processed by the chemometric approach of partial least squares. The experimental calibration set was composed of 16 sample solutions using an orthogonal calibration design for two component mixtures. The proposed method offers the potential advantages of high sensitivity, simplicity and rapidity for Co2+ and Cu2+ determination, and was successfully applied to the simultaneous determination of both analytes in real water sample. The present paper demonstrated that the simultaneous determination of two metal ions without any prior separation has been possible using flow-injection CL system. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 50 条
  • [1] Flow-injection simultaneous chemiluminescence determination of ascorbic acid and L-cysteine with partial least squares calibration
    Li, BX
    Wang, DM
    Xu, CL
    Zhang, ZJ
    [J]. MICROCHIMICA ACTA, 2005, 149 (3-4) : 205 - 212
  • [2] Flow-Injection Simultaneous Chemiluminescence Determination of Ascorbic Acid and L-Cysteine with Partial Least Squares Calibration
    Baoxin Li
    Dongmei Wang
    Chunli Xu
    Zhujun Zhang
    [J]. Microchimica Acta, 2005, 149 : 205 - 212
  • [3] Simultaneous determination of Cu(II), Ni(II) and Zn(II) by peroxyoxalate chemiluminescence using Partial Least Squares calibration
    Murillo Pulgarin, J. A.
    Garcia Bermejo, L. F.
    Carrasquero, A.
    [J]. ANALYST, 2011, 136 (02) : 304 - 308
  • [4] FLOW-INJECTION CHEMILUMINESCENCE DETERMINATION OF COBALT(II) AND MANGANESE(II)
    LIN, QX
    GUIRAUM, A
    ESCOBAR, R
    DELAROSA, FF
    [J]. ANALYTICA CHIMICA ACTA, 1993, 283 (01) : 379 - 385
  • [5] Flow-Injection Chemiluminescence Determination of Cobalt(II) with Umbelliferon
    Watanabe, Kunihiro
    Onishi, Haruka
    Shitanda, Isao
    Itagaki, Masayuki
    [J]. BUNSEKI KAGAKU, 2009, 58 (06) : 531 - 537
  • [6] Simultaneous spectrophotometric determination of copper(II) and zinc(II) using partial least squares regression
    Kompany-Zareh, M
    Safavi, A
    Hoseini, M
    [J]. CHEMIA ANALITYCZNA, 2004, 49 (02): : 225 - 233
  • [7] Simultaneous calibration in flow-injection analysis using multiple-injection signals evaluated by partial least squares
    Schöngarth, K
    Hitzmann, B
    [J]. ANALYTICA CHIMICA ACTA, 1998, 363 (2-3) : 183 - 189
  • [8] SIMULTANEOUS DETERMINATION OF COBALT AND NICKEL BY FLOW-INJECTION ANALYSIS AND PARTIAL LEAST-SQUARES REGRESSION WITH OUTLIER DETECTION
    RIDDER, C
    NORGAARD, L
    [J]. CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1992, 14 (1-3) : 297 - 303
  • [9] Chemometrics-assisted simultaneous determination of cobalt(II) and chromium(III) with flow-injection chemiluminescence method
    Li, Baoxin
    Wang, Dongmei
    Lv, Hagen
    Zhang, Zhujun
    [J]. SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2006, 65 (01) : 67 - 72
  • [10] Simultaneous determination of iron, copper and cobalt in food samples by diode array detection-flow injection analysis using partial least squares calibration model
    Mi Jian-ping
    Li Yuan-qian
    Zou Xiao-li
    Zheng Bo
    Yang Jing-guo
    [J]. SPECTROSCOPY AND SPECTRAL ANALYSIS, 2007, 27 (06) : 1188 - 1191