Micro-CT imaging assessment of dobutamine-induced cardiac stress in rats

被引:12
|
作者
Badea, Cristian T. [1 ]
Hedlund, Laurence W. [1 ]
Cook, James [1 ]
Berridge, Brian R. [2 ]
Johnson, G. Allan [1 ]
机构
[1] Duke Univ, Med Ctr, Ctr Vivo Microscopy, Dept Radiol, Durham, NC 27710 USA
[2] GlaxoSmithKline Safety Assessment, Res Triangle Pk, NC 27709 USA
关键词
Cardiac; Small animal imaging; Lung; Micro-CT; Stress; Dobutamine; COMPUTED-TOMOGRAPHY; CONTRAST AGENT; MOUSE HEART; MASS; RECONSTRUCTION; MODEL; MRI;
D O I
10.1016/j.vascn.2010.04.002
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Introduction: Dobutamine (DOB) stress in animal models of heart disease has been imaged so far using echocardiography and magnetic resonance imaging. The purpose of this study was to assess normal response to DOB stress in rats using anatomical and functional data using micro-computed tomography (CT). Methods: Ten normal adult male rats were first injected with a liposomal-based blood pool contrast agent and next infused with DOB via a tail vein catheter. Using prospective gating, 5 pairs of systole/diastole micro-CT images were acquired (a) pre-infusion baseline; (b) at heart rate plateau during infusion of 10 mu g/kg/min DOB; (c) at post-DOB infusion baseline; (d) at heart rate plateau during infusion of 30 mu g/kg/min DOB; and (e) after post-infusion return to baseline. Heart rate, peripheral and breathing distensions were monitored by oximetry. Micro-CT images with 88-mu m isotropic voxels were segmented to obtain cardiac function based on volumetric measurements of the left ventricle. Results: DOB stress increased heart rate and cardiac output with both doses. Ejection fraction increased above baseline by an average of 35.9% with the first DOB dose and 18.4% with the second dose. No change was observed in the relative peripheral arterial pressures associated with the significant increases in cardiac output. Discussion: Micro-CT proved to be a robust imaging method able to provide isotropic data on cardiac morphology and function. Micro-CT has the advantage of being faster and more cost-effective than MR and is able to provide higher accuracy than echocardiography. The impact of such an enabling technology can be enormous in evaluating cardiotoxic effects of various test drugs. (C) 2010 Elsevier Inc. All rights reserved.
引用
收藏
页码:24 / 29
页数:6
相关论文
共 50 条
  • [1] DOBUTAMINE-INDUCED CARDIAC ADAPTATIONS - COMPARISON WITH EXERCISE-TRAINED AND SEDENTARY RATS
    DAVIDSON, WR
    BANERJEE, SP
    LIANG, CS
    AMERICAN JOURNAL OF PHYSIOLOGY, 1986, 250 (05): : H725 - H730
  • [2] DOBUTAMINE-INDUCED ATRIAL FIBRILLATION DURING DOBUTAMINE STRESS ECHOCARDIOGRAPHY
    Sinha, A.
    Acharaya, Y.
    Bhattarai, J.
    Kumar, R.
    Shirani, J.
    CARDIOLOGY, 2015, 131 : 390 - 390
  • [3] Systemic administration of micro-dystrophin restores cardiac geometry and prevents dobutamine-induced cardiac pump failure
    Townsend, DeWayne
    Blankinship, Michael J.
    Allen, James M.
    Gregorevic, Paul
    Chamberlain, Jeffrey S.
    Metzger, Joseph M.
    MOLECULAR THERAPY, 2007, 15 (06) : 1086 - 1092
  • [4] Micro-CT with respiratory and cardiac gating
    Badea, C
    Hedlund, LW
    Johnson, GA
    MEDICAL PHYSICS, 2004, 31 (12) : 3324 - 3329
  • [5] Micro-CT Imaging of MEMS Components
    Ryan F. Fisher
    David E. Hintenlang
    Journal of Nondestructive Evaluation, 2008, 27 : 115 - 125
  • [6] Dobutamine-induced stress affects intracellular uptake of manganese:: A quantitative magnetic resonance imaging study in pigs
    Eriksson, R
    Johansson, L
    Bjerner, T
    Ahlström, H
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2005, 21 (04) : 360 - 364
  • [7] Cryogenic micro-CT imaging of tissues
    Jorgensen, Steven M.
    Turner, Russell T.
    Ritman, Erik L.
    Annals of Biomedical Engineering, 2000, 28 (SUPPL. 1)
  • [8] Respiratory gated micro-CT imaging
    Cody, D
    Collier, D
    Johnson, E
    Rivera, B
    Price, R
    MEDICAL PHYSICS, 2003, 30 (06) : 1408 - 1408
  • [9] Whole Placentome Imaging by Micro-CT
    Barapatre, Nirav
    Achterhold, Klaus
    Kampfer, Cornelia
    Rubelmann, Tanja
    von Koch, Franz Edler
    Pfeiffer, Franz
    Schmitz, Christoph
    Frank, Hans-Georg
    REPRODUCTIVE SCIENCES, 2023, 30 : 157A - 157A
  • [10] Micro-CT Imaging of MEMS Components
    Fisher, Ryan F.
    Hintenlang, David E.
    JOURNAL OF NONDESTRUCTIVE EVALUATION, 2008, 27 (04) : 115 - 125