Ring and peg electrodes for minimally-Invasive and long-term sub-scalp EEG recordings

被引:11
|
作者
Benovitski, Y. B. [1 ]
Lai, A. [2 ]
McGowan, C. C. [1 ]
Burns, O. [1 ]
Maxim, V. [1 ]
Nayagam, D. A. X. [1 ,3 ]
Millard, R. [1 ]
Rathbone, G. D. [1 ]
le Chevoir, M. A. [6 ]
Williams, R. A. [3 ]
Grayden, D. B. [5 ,7 ]
May, C. N. [4 ]
Murphy, M. [2 ]
D'Souza, W. J. [2 ]
Cook, M. J. [2 ]
Williams, C. E. [1 ]
机构
[1] Bion Inst, 384-388 Albert St, Melbourne, Vic 3002, Australia
[2] Univ Melbourne, St Vincents Hosp, Dept Med, Melbourne, Vic, Australia
[3] Univ Melbourne, St Vincents Hosp, Dept Anat Pathol, Melbourne, Vic, Australia
[4] Univ Melbourne, Florey Inst Neurosci & Mental Hlth, Melbourne, Vic, Australia
[5] Univ Melbourne, Dept Elect & Elect Engn, Melbourne, Vic, Australia
[6] Univ Melbourne, Fac Vet & Agr Sci, Melbourne, Vic, Australia
[7] Univ Melbourne, Ctr Neural Engn, Melbourne, Vic, Australia
基金
英国医学研究理事会;
关键词
Long-term EEG; Epilepsy; Sub-scalp electrode; Minimally-invasive; Stable; Removable; EPILEPSY; MISDIAGNOSIS; SHEEP;
D O I
10.1016/j.eplepsyres.2017.06.003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: Minimally-invasive approaches are needed for long-term reliable Electroencephalography (EEG) recordings to assist with epilepsy diagnosis, investigation and more naturalistic monitoring. This study compared three methods for long-term implantation of sub-scalp EEG electrodes. Methods: Three types of electrodes (disk, ring, and peg) were fabricated from biocompatible materials and implanted under the scalp in five ambulatory ewes for 3 months. Disk electrodes were inserted into sub-pericranial pockets. Ring electrodes were tunneled under the scalp. Peg electrodes were inserted into the skull, close to the dura. EEG was continuously monitored wirelessly. High resolution CT imaging, histopathology, and impedance measurements were used to assess the status of the electrodes at the end of the study. Results: EEG amplitude was larger in the peg compared with the disk and ring electrodes (p < 0.05). Similarly, chewing artifacts were lower in the peg electrodes (p < 0.05). Electrode impedance increased after long-term implantation particularly for those within the bone (p < 0.01). Micro-CT scans indicated that all electrodes stayed within the sub-scalp layers. All pegs remained within the burr holes as implanted with no evidence of extrusion. Eight of 10 disks partially eroded into the bone by 1.0 mm from the surface of the skull. The ring arrays remained within the sub-scalp layers close to implantation site. Histology revealed that the electrodes were encapsulated in a thin fibrous tissue adjacent to the pericranium. Overlying this was a loose connective layer and scalp. Erosion into the bone occurred under the rim of the sub-pericranial disk electrodes. Conclusions: The results indicate that the peg electrodes provided high quality EEG, mechanical stability, and lower chewing artifact. Whereas, ring electrode arrays tunneled under the scalp enable minimal surgical techniques to be used for implantation and removal.
引用
收藏
页码:29 / 37
页数:9
相关论文
共 50 条
  • [1] Preclinical safety study of a fully implantable, sub-scalp ring electrode array for long-term EEG recordings
    Benovitski, Yuri B.
    Lai, Alan
    Saunders, Alexia
    McGowan, Ceara C.
    Burns, Owen
    Nayagam, David A. X.
    Millard, Rodney
    Harrison, Mark
    Rathbone, Graeme D.
    Williams, Richard A.
    May, Clive N.
    Murphy, Michael
    D'Souza, Wendyl J.
    Cook, Mark J.
    Williams, Chris E.
    [J]. JOURNAL OF NEURAL ENGINEERING, 2022, 19 (03)
  • [2] Preliminary experience using a minimally invasive sub-scalp device for ultra-long term seizure monitoring
    Cook, M.
    D'Souza, W.
    Seneviratne, U.
    Seiderer, L.
    McLean, K.
    Heasman, J.
    Leavens, J.
    Ringo, S.
    Benovitski, Y.
    Williams, C.
    Bulluss, K.
    Murphy, M.
    Lai, A.
    [J]. EUROPEAN JOURNAL OF NEUROLOGY, 2021, 28 : 415 - 415
  • [3] Seizure Forecasting Using a Novel Sub-Scalp Ultra-Long Term EEG Monitoring System
    Stirling, Rachel E.
    Maturana, Matias, I
    Karoly, Philippa J.
    Nurse, Ewan S.
    McCutcheon, Kate
    Grayden, David B.
    Ringo, Steven G.
    Heasman, John M.
    Hoare, Rohan J.
    Lai, Alan
    D'Souza, Wendyl
    Seneviratne, Udaya
    Seiderer, Linda
    McLean, Karen J.
    Bulluss, Kristian J.
    Murphy, Michael
    Brinkmann, Benjamin H.
    Richardson, Mark P.
    Freestone, Dean R.
    Cook, Mark J.
    [J]. FRONTIERS IN NEUROLOGY, 2021, 12
  • [4] Classification of long-term EEG recordings
    Kosar, K
    Lhotska, L
    Krajca, V
    [J]. BIOLOGICAL AND MEDICAL DATA ANALYSIS, PROCEEDINGS, 2004, 3337 : 322 - 332
  • [5] Toward Long-term and Accurate Augmented-Reality Display for Minimally-Invasive Surgery
    Puerto-Souza, Gustavo A.
    Mariottini, Gian Luca
    [J]. 2013 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2013, : 5384 - 5389
  • [6] Long-term, minimally-invasive access to the portal vein in rodents: An experimental study.
    Gervaz, P
    Scholl, B
    Zhao, RH
    Jonathan, E
    Wexner, S
    Gillet, M
    [J]. GASTROENTEROLOGY, 2000, 118 (04) : A1513 - A1513
  • [7] Long-term Stability of Interictal Spike Trajectories in Pediatric Invasive EEG Recordings
    Tomlinson, Samuel B.
    Wong, Jeremy N.
    Conrad, Erin C.
    Marsh, Eric D.
    [J]. NEUROLOGY, 2019, 92 (15)
  • [8] An Algorithm for the Automated Detection of Epileptic Seizures in Long-Term Scalp EEG Recordings in Clinical Routine
    Hopfengaertner, R.
    Kerling, F.
    Greim, V.
    Stefan, H.
    [J]. KLINISCHE NEUROPHYSIOLOGIE, 2008, 39 (03) : 175 - 182
  • [9] An efficient, robust and fast method for the offline detection of epileptic seizures in long-term scalp EEG recordings
    Hopfengaertner, R.
    Kerling, F.
    Bauer, V.
    Stefan, H.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2007, 118 (11) : 2332 - 2343
  • [10] A comparison of subdermal wire electrodes with collodion-applied disk electrodes in long-term EEG recordings in ICU
    Young, G. Bryan
    Ives, John R.
    Chapman, Martin G.
    Mirsattari, Seyed M.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2006, 117 (06) : 1376 - 1379