Safety Analysis of All-Inside Arthroscopic Repair of Peripheral Triangular Fibrocartilage Complex

被引:15
|
作者
Waterman, Scott M. [1 ]
Slade, Dirk [2 ]
Masini, Brendan D. [3 ]
Owens, Brett D. [4 ]
机构
[1] Walter Reed Natl Mil Med Ctr, Bethesda, MD 20889 USA
[2] William Beaumont Army Med Ctr, El Paso, TX 79920 USA
[3] San Antonio Mil Med Ctr, San Antonio, TX USA
[4] Keller Army Community Hosp, West Point, NY USA
关键词
DORSAL SENSORY BRANCH; PARTIAL EXCISION; ARTICULAR DISK; ISOLATED TEARS; ULNAR NERVE; WRIST; MANAGEMENT; ANATOMY; INJURY;
D O I
10.1016/j.arthro.2010.02.027
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to determine whether an all-inside peripheral triangular fibrocartilage complex (TFCC) repair using the FasT-Fix device (Smith & Nephew Endoscopy, Andover, MA) is safe by measuring the proximity of the anchors to ulnar-sided anatomic structures. Methods: Eleven fresh-frozen cadaveric wrists were thawed and placed in traction. Under direct arthroscopic visualization, an all-inside arthroscopic peripheral TFCC repair was completed by placing a single FasT-Fix device in a vertical mattress fashion. The wrists were then dissected to visualize the 2 anchors. The distance between these anchors and the flexor carpi ulnaris (FCU), extensor carpi ulnaris (ECU), and dorsal branch of the ulnar sensory nerve (DBUN) were measured with digital calipers and recorded. Results: The peripheral anchor averaged 4.2 mm (range, 0 to 14 mm) from the ECU tendon, 3.8 mm (range, 0 to 9 mm) from the DBUN, and 8.3 mm (range, 1 to 15 mm) from the FCU tendon. The central anchor averaged 9.6 mm (range, 2 to 15 mm) from the ECU tendon, 6.8 mm (range, 1 to 13 mm) from the DBUN, and 7.6 mm (range, 1 to 13 mm) from the FCU tendon. Conclusions: This study exposes some safety concerns with the all-inside peripheral TFCC repair using the FasT-Fix device, which was found to reside in close proximity to the ECU, FCU, and DBUN. In multiple wrists the anchors were noted to underlie the anatomic structure that we measured, making it possible to pierce these structures with the needle before deployment of the anchor. Clinical Relevance: Though technically feasible, all-inside arthroscopic repair of the peripheral TFCC risks injury to the ulnar-sided anatomy.
引用
收藏
页码:1474 / 1477
页数:4
相关论文
共 50 条
  • [1] A novel technique of all-inside arthroscopic triangular fibrocartilage complex repair
    Yao, Jeffrey
    Dantuluri, Phani
    Osterman, A. Lee
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (12): : 1357.e1 - 1357.e4
  • [2] All-Inside Versus Outside-in Repair of Triangular Fibrocartilage Complex Peripheral Tears
    Fones, Lilah
    Cole, Keegan P.
    Kwok, Moody
    Gallant, Greg G.
    Tosti, Rick
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2025, 50 (01): : 96e1 - 96e6
  • [3] A method for all-inside arthroscopic repair of Palmer 1B triangular fibrocartilage complex tears
    Böhringer, G
    Schädel-Höpfner, M
    Petermann, J
    Gotzen, L
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (02): : 211 - 213
  • [4] All-Arthroscopic Repair of Peripheral Triangular Fibrocartilage Complex Tears
    Yao, Jeffrey
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2010, 18 (03) : 168 - 172
  • [5] Biomechanical Analysis of All-Inside, Arthroscopic Suture Repair Versus Extensor Retinaculum Capsulorrhaphy for Triangular Fibrocartilage Complex Tears With Instability
    Patel, Amar A.
    Alhandi, Ali A.
    Milne, Edward
    Dy, Christopher J.
    Latta, Loren L.
    Ouellette, E. Anne
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2016, 41 (03): : 387 - 393
  • [6] A new arthroscopic repair technique for triangular fibrocartilage complex using an intracapsular suture: an outside-in transfer all-inside repair
    Jiasong Zhao
    Yanming Lin
    Lang Li
    Yong Huang
    Journal of Orthopaedic Surgery and Research, 18
  • [7] A new arthroscopic repair technique for triangular fibrocartilage complex using an intracapsular suture: an outside-in transfer all-inside repair
    Zhao, Jiasong
    Lin, Yanming
    Li, Lang
    Huang, Yong
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [8] Arthroscopic all-inside repair of Palmer type 1B triangular fibrocartilage complex tears: a technical note
    Choon Key Lee
    Hyung Lae Cho
    Kwang Am Jung
    Jae Yeong Jo
    Jung Hoei Ku
    Knee Surgery, Sports Traumatology, Arthroscopy, 2008, 16 : 94 - 97
  • [9] Arthroscopic all-inside repair of Palmer type 1B triangular fibrocartilage complex tears: a technical note
    Lee, Choon Key
    Cho, Hyung Lae
    Jung, Kwang Am
    Jo, Jae Yeong
    Ku, Jung Hoei
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2008, 16 (01) : 94 - 97
  • [10] Commentary on "Biomechanical Analysis of All-Inside, Arthroscopic Suture Repair Versus Extensor Retinaculum Capsulorrhaphy for Triangular Fibrocartilage Complex Tears With Instability"
    Tan, Virak
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2016, 41 (03): : 394 - 394