Electrical conductivity sensors for water penetration monitoring in building masonry materials

被引:18
|
作者
Guizzardi, M. [1 ,2 ]
Derome, D. [2 ]
Mannes, D. [3 ]
Vonbank, R. [2 ]
Carmeliet, J. [1 ]
机构
[1] ETH, Zurich, Switzerland
[2] Swiss Fed Inst Mat Sci & Technol, Empa, Dubendorf, Switzerland
[3] Paul Scherrer Inst, Villigen, Switzerland
关键词
Moisture content sensor; Capillary uptake; Electrical conductivity; Neutron radiography; CONCRETE STRUCTURES; MOISTURE; SYSTEMS;
D O I
10.1617/s11527-015-0666-7
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Water penetration in porous building materials can cause damage in building components exposed to wet environmental conditions. A system to monitor water penetration by means of electrical conductivity measurements is presented (Gummerson et al. Build Environ 15:101-108, 1980). The sensor allows non-destructive and continuous monitoring of different layers of building envelopes with high space and time resolution. Capillary uptake experiments have been performed to assess the reliability of the developed system. Sensors data are compared to the results of the analysis of neutron radiographs taken during the experiments. These sensors are easy to apply in different positions, even deep in the structural components where direct gravimetric investigation is not possible. Electrical conductivity measurements provide a good temporal description of the capillary uptake process, however a calibration for moisture content quantification could not yet be achieved.
引用
收藏
页码:2535 / 2547
页数:13
相关论文
共 50 条
  • [31] Measurements of the electrical conductivity of water
    Jones, RG
    IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2002, 149 (06) : 320 - 322
  • [32] ELECTRICAL-CONDUCTIVITY OF POLYCRYSTALLINE MATERIALS
    WILLEMSE, MWM
    CASPERS, WJ
    JOURNAL OF MATHEMATICAL PHYSICS, 1979, 20 (08) : 1824 - 1831
  • [33] ELECTRICAL CONDUCTIVITY OF POLYMER INSULATING MATERIALS
    ADAMEC, V
    ZEITSCHRIFT FUR ANGEWANDTE PHYSIK, 1970, 29 (05): : 291 - &
  • [34] Monitoring of the absolute water content in porous materials based on embedded humidity sensors
    Strangfeld, Christoph
    Kruschwitz, Sabine
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 177 : 511 - 521
  • [35] IONIC CONDUCTIVITY IN ELECTRICAL INSULATING MATERIALS
    TAREEV, BM
    RENNE, VT
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 1966, 25 (11): : 514 - &
  • [36] Influent pollutant monitoring in decentralised treatment facilities using electrical conductivity sensors: experimental and modelling insights
    Yu, Qiangqiang
    Liu, Rui
    Liang, Zhiwei
    Li, Chenhui
    Song, Xiaoyan
    Ye, Linyi
    Chen, Lujun
    ENVIRONMENTAL SCIENCE-WATER RESEARCH & TECHNOLOGY, 2022, 8 (08) : 1639 - 1649
  • [37] WATER-MOVEMENT IN POROUS BUILDING-MATERIALS .2. HYDRAULIC SUCTION AND SORPTIVITY OF BRICK AND OTHER MASONRY MATERIALS
    GUMMERSON, RJ
    HALL, C
    HOFF, WD
    BUILDING AND ENVIRONMENT, 1980, 15 (02) : 101 - 108
  • [38] Damage monitoring of an historical masonry building by the acoustic emission technique
    Carpinteri, A.
    Lacidogna, G.
    MATERIALS AND STRUCTURES, 2006, 39 (02) : 161 - 167
  • [39] Damage Monitoring of an Historical Masonry Building by the Acoustic Emission Technique
    A. Carpinteri
    G. Lacidogna
    Materials and Structures, 2006, 39 : 161 - 167
  • [40] Sustainability of Building Materials: Embodied Energy and Embodied Carbon of Masonry
    Asdrubali, Francesco
    Grazieschi, Gianluca
    Roncone, Marta
    Thiebat, Francesca
    Carbonaro, Corrado
    ENERGIES, 2023, 16 (04)