Influent pollutant monitoring in decentralised treatment facilities using electrical conductivity sensors: experimental and modelling insights

被引:0
|
作者
Yu, Qiangqiang [1 ]
Liu, Rui [1 ]
Liang, Zhiwei [2 ]
Li, Chenhui [3 ]
Song, Xiaoyan [1 ]
Ye, Linyi [1 ]
Chen, Lujun [1 ,4 ]
机构
[1] Tsinghua Univ, Zhejiang Prov Key Lab Water Sci & Technol, Dept Environm Yangtze Delta Reg Inst, Jiaxing 314006, Zhejiang, Peoples R China
[2] Zhejiang Univ, Acad Water Sci & Environm Engn, Inst Environm Sci & Technol, Dept Environm Engn, Hangzhou 310058, Peoples R China
[3] Tongji Zhejiang Coll, Jiaxing 314006, Peoples R China
[4] Tsinghua Univ, Sch Environm, Beijing 100084, Peoples R China
关键词
WASTE-WATER TREATMENT; SYSTEMS; SPECTROSCOPY; WASTEWATERS; PERFORMANCE; INDICATORS; POTASSIUM; REMOVAL; IMPACT;
D O I
10.1039/d1ew00887k
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Electrical conductivity (EC) is a common and cheap water monitoring sensor, which to some extent reflects the water body pollution level qualitatively. In this study, characteristic analysis of domestic sewage in decentralised treatment facilities located in the plain and mountainous rural areas of Eastern China showed that influent TN/NH3-N/TP concentrations were strongly and linearly correlated with influent EC values. EC source apportionment indicated that although no single ion in rural domestic sewage dominated the EC value, the EC was packed with vast amounts of information on pollutant content and could be precisely predicted using a support vector machine (SVM) regression model (R-2 = 0.9063). According to field investigation and dilution simulation analysis, the mechanism of the correlations between influent TN/NH3-N/TP concentration and EC values was confirmed and attributed to the dilution caused by extraneous water during pipeline transport. Particularly, although the dilution processes in the plain and mountainous areas were similar and both the dilution coefficients were speculated to obey a Poisson distribution, the average dilution coefficient in the plain area was 0.35 +/- 0.16 with lambda = 4 while that in the mountainous area was 0.23 +/- 0.15 with lambda = 2. Our results demonstrate that the EC sensor provides a cheap, rapid and reliable alternative influent pollutant monitoring method for decentralised treatment facilities in rural areas and also show that the essential parameter to form a linear correlation is dilution.
引用
收藏
页码:1639 / 1649
页数:11
相关论文
共 4 条
  • [1] Electrical conductivity in rural domestic sewage: An indication for comprehensive concentrations of influent pollutants and the effectiveness of treatment facilities
    Yu, Qiangqiang
    Liu, Rui
    Chen, Jiangjie
    Chen, Lujun
    [J]. INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2019, 143
  • [2] Health monitoring of composite patch repairs using CFBG sensors: Experimental study and numerical modelling
    Rito, R. L.
    Crocombe, A. D.
    Ogin, S. L.
    [J]. COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2017, 100 : 255 - 268
  • [3] A Novel Experimental Study and Analysis of Electrocoagulation Process for Textile Wastewater Treatment using Various Sensors with Integration of IoT Monitoring System
    Karthikeyan, M.
    Vijayachitra, S.
    [J]. JOURNAL OF NEW MATERIALS FOR ELECTROCHEMICAL SYSTEMS, 2021, 24 (02) : 95 - 102
  • [4] Tristimulus mathematical treatment application for monitoring fungi infestation evolution in melon using the electrical response of carbon nanostructure-polymer composite based sensors
    Greenshields, Marcia W. C. C.
    Mamo, Messai A.
    Coville, Neil J.
    Pimentel, Ida Chapaval
    Destro, Joao Guilherme
    Porsani, Mariana V.
    Bozza, Angela
    Huemmelgen, Ivo A.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 378 - 384