Electroanalytical Determination of Morpholine as a Corrosion Inhibitor at a Cathodically Pretreated Boron-Doped Diamond Electrode

被引:11
|
作者
Rocha, Luana Rianne [1 ]
D'Elia, Eliane [2 ]
Medeiros, Roberta Antigo [1 ]
Teixeira Tarley, Cesar Ricardo [1 ,3 ]
机构
[1] Univ Estadual Londrina, Ctr Ciencias Exatas, Dept Quim, Londrina, PR, Brazil
[2] Univ Fed Rio de Janeiro, Inst Quim, Rio De Janeiro, Brazil
[3] Univ Estadual Campinas UNICAMP, Inst Nacl Ciencia & Tecnol INCT Bioanalit, Inst Quim, Dept Quim Analit, Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Boron-doped diamond electrode; cyclic voltammetry; differential pulse voltammetry; morpholine; square-wave voltammetry; CHROMATOGRAPHIC DETERMINATION; VOLTAMMETRIC DETERMINATION; MILD-STEEL; WATER; AIR; DERIVATIVES; PRODUCTS;
D O I
10.1080/00032719.2018.1515953
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electroanalytical method for the determination of morpholine, a corrosion inhibitor, was developed at a cathodically pretreated boron-doped diamond electrode (BDDE). The voltammetric response of morpholine at the BDDE in 0.1 mol L-1 KCl (pH 10) shows an irreversible oxidation process at approximately 1.3 V vs. Ag/AgCl in 3.0 mol L-1 KCl. Using cyclic voltammetry, the number of electrons involved in the morpholine electroxidation mechanism was found to be 1. The application of chronoamperometry showed that the apparent diffusion coefficient (D-0) was 2.99 x 10(-6) cm(2) s(-1). Using square wave voltammetry under the optimized conditions (frequency of 30.0 Hz, pulse amplitude of 100 mV and step potential of 20 mV at pH 10.0), the developed method provided limits of detection and quantification of 2.1 and 6.9 mg L-1, respectively, with a linear range from 5.0 to 100.0 mg L-1 (r = 0.991). Intraday (n = 10) and interday (two consecutive day) precision values assessed as the relative standard deviation for solutions containing 30.0, 60.0, and 90.0 mg L-1 of morpholine were from 0.41 to 5.86% and 0.92 to 3.19%, respectively. The feasibility of the method for the interference-free determination of morpholine was verified by the analysis of synthetic boiler water samples containing CaCO3, Na2SO3, Na3PO4, FeCl3, and humic acid as organic matter. In addition, hydrazine was added as a possible interfering compound because of its widespread use in corrosion inhibition. Recovery values from 90.9 to 109.4% were obtained in the synthetic boiler water, thereby attesting to the accuracy of the method.
引用
收藏
页码:1083 / 1096
页数:14
相关论文
共 50 条
  • [31] Square-wave voltammetric determination of rosuvastatin calcium in pharmaceutical and biological fluid samples using a cathodically pretreated boron-doped diamond electrode
    Silva, Tiago A.
    Pereira, Gabriel F.
    Fatibello-Filho, Orlando
    Eguiluz, Katlin I. B.
    Salazar-Banda, Giancarlo R.
    DIAMOND AND RELATED MATERIALS, 2015, 58 : 103 - 109
  • [32] Voltammetric determination of natamycin using a cathodically pretreated boron -doped diamond electrode in the presence of sodium dodecyl sulfate
    Mielech-Lukasiewicz, Katarzyna
    Leoniuk, Marta
    MICROCHEMICAL JOURNAL, 2020, 159
  • [33] The Immunosuppressive drug - Rapamycin - Electroanalytical Sensing Using Boron-Doped Diamond electrode
    Stankovic, Dalibor M.
    Katcher, Kurt
    ELECTROCHIMICA ACTA, 2015, 168 : 76 - 81
  • [34] Development of an Electroanalytical Method for Ronidazole Determination in Environmental and Food Matrices Using Boron-Doped Diamond Electrode
    Bettio, Guilherme
    Okumura, Leonardo L.
    Silva, Rene C.
    Silva, Tiago A.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2024, 35 (04)
  • [35] Electroanalytical Characteristics of Lercanidipine and its Voltammetric Determination in Pharmaceuticals and Human Serum on Boron-Doped Diamond Electrode
    Altun, Yuksel
    Uslu, Bengi
    Ozkan, Sibel A.
    ANALYTICAL LETTERS, 2010, 43 (12) : 1958 - 1975
  • [36] Voltammetric behavior of rutin at a boron-doped diamond electrode. Its electroanalytical determination in a pharmaceutical formulation
    Pinar, Pinar Talay
    Yardim, Yavuz
    Senturk, Zuhre
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2013, 11 (10): : 1674 - 1681
  • [37] Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode
    Santos, Anderson M.
    Vicentini, Fernando C.
    Deroco, Patricia B.
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2015, 26 (10) : 2159 - 2168
  • [38] Simple and Rapid Quantification of Folic Acid in Pharmaceutical Tablets using a Cathodically Pretreated Highly Boron-doped Polycrystalline Diamond Electrode
    Cinkova, Kristina
    Svorc, Lubomir
    Satkovska, Petra
    Vojs, Marian
    Michniak, Pavol
    Marton, Marian
    ANALYTICAL LETTERS, 2016, 49 (01) : 107 - 121
  • [39] Electroanalytical determination of carbaryl in natural waters on boron doped diamond electrode
    Codognoto, L
    Tanimoto, ST
    Pedrosa, VA
    Suffredini, HB
    Machado, SAS
    Avaca, LA
    ELECTROANALYSIS, 2006, 18 (03) : 253 - 258
  • [40] Electroanalytical Applications of Boron Doped Diamond Electrode
    Gao Chengyao
    Chang Ming
    Li Xiaowei
    Li Cuiping
    PROGRESS IN CHEMISTRY, 2011, 23 (05) : 951 - 962