Electroanalytical Determination of Morpholine as a Corrosion Inhibitor at a Cathodically Pretreated Boron-Doped Diamond Electrode

被引:11
|
作者
Rocha, Luana Rianne [1 ]
D'Elia, Eliane [2 ]
Medeiros, Roberta Antigo [1 ]
Teixeira Tarley, Cesar Ricardo [1 ,3 ]
机构
[1] Univ Estadual Londrina, Ctr Ciencias Exatas, Dept Quim, Londrina, PR, Brazil
[2] Univ Fed Rio de Janeiro, Inst Quim, Rio De Janeiro, Brazil
[3] Univ Estadual Campinas UNICAMP, Inst Nacl Ciencia & Tecnol INCT Bioanalit, Inst Quim, Dept Quim Analit, Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Boron-doped diamond electrode; cyclic voltammetry; differential pulse voltammetry; morpholine; square-wave voltammetry; CHROMATOGRAPHIC DETERMINATION; VOLTAMMETRIC DETERMINATION; MILD-STEEL; WATER; AIR; DERIVATIVES; PRODUCTS;
D O I
10.1080/00032719.2018.1515953
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electroanalytical method for the determination of morpholine, a corrosion inhibitor, was developed at a cathodically pretreated boron-doped diamond electrode (BDDE). The voltammetric response of morpholine at the BDDE in 0.1 mol L-1 KCl (pH 10) shows an irreversible oxidation process at approximately 1.3 V vs. Ag/AgCl in 3.0 mol L-1 KCl. Using cyclic voltammetry, the number of electrons involved in the morpholine electroxidation mechanism was found to be 1. The application of chronoamperometry showed that the apparent diffusion coefficient (D-0) was 2.99 x 10(-6) cm(2) s(-1). Using square wave voltammetry under the optimized conditions (frequency of 30.0 Hz, pulse amplitude of 100 mV and step potential of 20 mV at pH 10.0), the developed method provided limits of detection and quantification of 2.1 and 6.9 mg L-1, respectively, with a linear range from 5.0 to 100.0 mg L-1 (r = 0.991). Intraday (n = 10) and interday (two consecutive day) precision values assessed as the relative standard deviation for solutions containing 30.0, 60.0, and 90.0 mg L-1 of morpholine were from 0.41 to 5.86% and 0.92 to 3.19%, respectively. The feasibility of the method for the interference-free determination of morpholine was verified by the analysis of synthetic boiler water samples containing CaCO3, Na2SO3, Na3PO4, FeCl3, and humic acid as organic matter. In addition, hydrazine was added as a possible interfering compound because of its widespread use in corrosion inhibition. Recovery values from 90.9 to 109.4% were obtained in the synthetic boiler water, thereby attesting to the accuracy of the method.
引用
收藏
页码:1083 / 1096
页数:14
相关论文
共 50 条
  • [11] Differential pulse voltammetric determination of albendazole in pharmaceutical tablets using a cathodically pretreated boron-doped diamond electrode
    Lourencao, Bruna C.
    Baccarin, Marina
    Medeiros, Roberta A.
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 707 : 15 - 19
  • [12] Electroanalytical determination of enrofloxacin based on the enhancement effect of the anionic surfactant at anodically pretreated boron-doped diamond electrode
    Donmez, Fatih
    Yardim, Yavuz
    Senturk, Zuhre
    DIAMOND AND RELATED MATERIALS, 2018, 84 : 95 - 102
  • [13] Simultaneous Voltammetric Determination of Antihypertensive Drugs Amlodipine and Atenolol in Pharmaceuticals Using a Cathodically Pretreated Boron-Doped Diamond Electrode
    Moraes, Jaqueline T.
    Eisele, Ana P. P.
    Salamanca-Neto, Carlos A. R.
    Scremin, Jessica
    Sartori, Elen R.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (07) : 1264 - 1272
  • [14] Voltammetric Method for the Simultaneous Determination of Melatonin and Pyridoxine in Dietary Supplements Using a Cathodically Pretreated Boron-doped Diamond Electrode
    Alpar, Nurcan
    Pinar, Pinar Talay
    Yardim, Yavuz
    Senturk, Zuehre
    ELECTROANALYSIS, 2017, 29 (07) : 1691 - 1699
  • [15] Square-wave voltammetric determination of bezafibrate in pharmaceutical formulations using a cathodically pretreated boron-doped diamond electrode
    Ardila, Jorge Armando
    Sartori, Elen Romao
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    TALANTA, 2013, 103 : 201 - 206
  • [16] Rapid Electroanalytical Method for Determination of Nebivolol at a 4 Boron-Doped Diamond Electrode
    Nigovic, Biljana
    Mornar, Ana
    Zavrski, Mario
    JOURNAL OF AOAC INTERNATIONAL, 2015, 98 (06) : 1535 - 1541
  • [17] Electroanalytical determination of sulfadiazine and sulfamethoxazole in pharmaceuticals using a boron-doped diamond electrode
    Souza, Cristine D.
    Braga, Otoniel C.
    Vieira, Iolanda C.
    Spinelli, Almir
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01): : 66 - 73
  • [18] Voltammetric sensing of triclosan in the presence of cetyltrimethylammonium bromide using a cathodically pretreated boron-doped diamond electrode
    Yardim, Yavuz
    Alpar, Nurcan
    Senturk, Zuhre
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2018, 98 (13) : 1226 - 1241
  • [19] Simple and rapid determination of loratadine in pharmaceuticals using square-wave voltammetry and a cathodically pretreated boron-doped diamond electrode
    Pires Eisele, Ana Paula
    Sartori, Elen Romao
    ANALYTICAL METHODS, 2015, 7 (20) : 8697 - 8703
  • [20] Electrochemical and analytical performance of cathodically pretreated boron-doped diamond electrode for the determination of oxazolidinone antibiotic linezolid in cationic surfactant media
    Pinar, Pinar Talay
    Senturk, Zuhre
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 878