A sensitive assay for the quantification of morphine and its active metabolites in human plasma and dried blood spots using high-performance liquid chromatography-tandem mass spectrometry

被引:63
|
作者
Clavijo, Claudia F. [1 ,2 ]
Hoffman, Keith L. [1 ]
Thomas, James J. [1 ]
Carvalho, Brendan
Chu, Larry F. [2 ]
Drover, David R. [2 ]
Hammer, Gregory B. [2 ]
Christians, Uwe [1 ]
Galinkin, Jeffrey L. [1 ,3 ]
机构
[1] Univ Colorado Denver, Clin Res & Dev iC42, Dept Anesthesiol, Aurora, CO 80045 USA
[2] Stanford Univ, Dept Anesthesia, Stanford, CA 94305 USA
[3] Childrens Hosp Denver, Aurora, CO 80045 USA
基金
美国国家卫生研究院;
关键词
Morphine; 3; beta-glucoronide; 6; beta-glucuronide; LC-MS/MS; Human plasma; Dried blood spots; SOLID-PHASE EXTRACTION; ELECTROSPRAY-IONIZATION; POSTOPERATIVE PAIN; BODY-FLUIDS; MORPHINE-6-GLUCURONIDE; PHARMACOKINETICS; SERUM;
D O I
10.1007/s00216-011-4775-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Opioids such as morphine are the cornerstone of pain treatment. The challenge of measuring the concentrations of morphine and its active metabolites in order to assess human pharmacokinetics and monitor therapeutic drugs in children requires assays with high sensitivity in small blood volumes. We developed and validated a semi-automated LC-MS/MS assay for the simultaneous quantification of morphine and its active metabolites morphine 3 beta-glucuronide (M3G) and morphine 6 beta-glucuronide (M6G) in human plasma and in dried blood spots (DBS). Reconstitution in water (DBS only) and addition of a protein precipitation solution containing the internal standards were the only manual steps. Morphine and its metabolites were separated on a Kinetex 2.6-mu m PFP analytical column using an acetonitrile/0.1% formic acid gradient. The analytes were detected in the positive multiple reaction mode. In plasma, the assay had the following performance characteristics: range of reliable response of 0.25-1000 ng/mL (r (2) > 0.99) for morphine, 1-1,000 ng/mL (r (2) > 0.99) for M3G, and 2.5-1,000 ng/mL for M6G. In DBS, the assay had a range of reliable response of 1-1,000 ng/mL (r (2) > 0.99) for morphine and M3G, and of 2.5-1,000 ng/mL for M6G. For inter-day accuracy and precision for morphine, M3G and M6G were within 15% of the nominal values in both plasma and DBS. There was no carryover, ion suppression, or matrix interferences. The assay fulfilled all predefined acceptance criteria, and its sensitivity using DBS samples was adequate for the measurement of pediatric pharmacokinetic samples using a small blood of only 20-50 mu L.
引用
收藏
页码:715 / 728
页数:14
相关论文
共 50 条
  • [41] Determination of remifentanil in neonatal dried blood spots by liquid chromatography-tandem mass spectrometry
    Trontelj, Jurij
    Rozman, Ales
    Mrhar, Ales
    [J]. ACTA PHARMACEUTICA, 2024, 74 (02) : 343 - 354
  • [42] The assay of Melatonin in saliva by high-performance liquid chromatography-tandem mass spectrometry
    Khan, S. A.
    George, R.
    Taylor, P.
    Charles, B. G.
    McGuire, T.
    Heussler, H.
    Cooper, D.
    Norris, R. L. G.
    [J]. THERAPEUTIC DRUG MONITORING, 2011, 33 (04) : 490 - 490
  • [43] Simultaneous quantification of atorvastatin and active metabolites in human plasma by liquid chromatography-tandem mass spectrometry using rosuvastatin as internal standard
    Nirogi, Ramakrishna V. S.
    Kandikere, Vishwottam N.
    Shukla, Manoj
    Mudigonda, Koteshwara
    Maurya, Santosh
    Boosi, Ravikurnar
    Anjaneyulu, Yerramilli
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (09) : 924 - 936
  • [44] Quantification of Glyphosate and Aminomethylphosphonic Acid in Human Urine Using High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Montesano, M. A.
    Kuklenyik, P.
    Whitehead, R. D., Jr.
    Jayatilaka, N. K.
    Needham, L. L.
    Barr, D. B.
    [J]. EPIDEMIOLOGY, 2008, 19 (06) : S91 - S91
  • [45] Quantification of ochratoxin A in foods by a stable isotope dilution assay using high-performance liquid chromatography-tandem mass spectrometry
    Lindenmeier, M
    Schieberle, P
    Rychlik, M
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1023 (01) : 57 - 66
  • [46] Quantification of docetaxel and its metabolites in human plasma by liquid chromatography/tandem mass spectrometry
    Hendrikx, J. J. M. A.
    Dubbelman, A. C.
    Rosing, H.
    Schinkel, A. H.
    Schellens, J. H. M.
    Beijnen, J. H.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (17) : 1925 - 1934
  • [47] Liquid chromatography-tandem mass spectrometry assay for the simultaneous quantification of simvastatin, lovastatin, atorvastatin, and their major metabolites in human plasma
    Wang, Jiang
    Luzum, Jasmine A.
    Phelps, Mitch A.
    Kitzmiller, Joseph P.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 983 : 18 - 25
  • [48] Quantification of riboflavin in human urine using high performance liquid chromatography-tandem mass spectrometry
    Bishop, Amanda M.
    Fernandez, Carolina
    Whitehead, Ralph D., Jr.
    Morales-A, Pilar
    Barr, Dana Boyd
    Wilder, Lynn C.
    Baker, Samuel E.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (20): : 1823 - 1826
  • [49] Simultaneous quantification of metformin and glipizide in human plasma by high-performance liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study
    Li, Ning
    Deng, Ying
    Qin, Feng
    Yu, Jia
    Li, Famei
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (02) : 191 - 196
  • [50] Development and validation of a liquid chromatography-tandem mass spectrometry assay for determination of raloxifene and its metabolites in human plasma
    Trontelj, Jurij
    Bogataj, Marija
    Marc, Janja
    Mrhar, Ales
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 855 (02): : 220 - 227